FDA Adverse Event Injury Summary report: N

UNKNOWN GAMMA 3 NAIL

MDR report key: 16378081 · Received February 15, 2023

Report

Report Number
0009610622-2023-00030
Event Type
Injury
Date Received
February 15, 2023
Date of Event
December 3, 2014
Report Date
February 15, 2023
Manufacturer
STRYKER TRAUMA KIEL
Product Code
HSB
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS COMPLAINT HAS BEEN GENERATED BASED ON FINDINGS IDENTIFIED DURING POST MARKET SURVEILLANCE LITERATURE REVIEW PUBLISHED BY THE ¿DEPARTMENT OF TRAUMA SURGERY, TRAUMA CENTER MURNAU, GERMANY¿. THE ARTICLE CAN BE FOUND AT HTTPS://LINK.SPRINGER.COM/ARTICLE/10.1007/S00402-014-2121-6. THE REPORTED EVENT COULD NOT BE CONFIRMED SINCE THE DEVICE WAS NOT RETURNED FOR EVALUATION AND NO OTHER ADDITIONAL INFORMATION WAS RECEIVED FROM THE AUTHOR.  MORE DETAILED INFORMATION ABOUT THE PATIENT'S MEDICAL HISTORY, THE EVENT DETAILS AND THE INVOLVED DEVICE(S) MUST BE AVAILABLE TO DETERMINE THE ROOT CAUSE.   IF ANY ADDITIONAL INFORMATION BECOMES AVAILABLE, THE INVESTIGATION WILL BE REOPENED AND RE-EVALUATED ACCORDINGLY.

Description of Event or Problem · 0

THE MANUFACTURER BECAME AWARE OF A LITERATURE PUBLISHED BY THE ¿DEPARTMENT OF TRAUMA SURGERY, TRAUMA CENTER MURNAU, GERMANY¿. THE TITLE OF THIS REPORT IS, ¿BREAKAGE OF CEPHALOMEDULLARY NAILING IN OPERATIVE TREATMENT OF TROCHANTERIC AND SUBTROCHANTERIC FEMORAL FRACTURES¿, PUBLISHED ON DECEMBER 3, 2014, WHICH IS ASSOCIATED WITH THE STRYKER ¿GAMMA 3 NAILING SYSTEM. THE ARTICLE CAN BE FOUND AT HTTPS://LINK.SPRINGER.COM/ARTICLE/10.1007/S00402-014-2121-6. THIS REPORT INCLUDES AN ANALYSIS OF THE CLINICAL DATA THAT WAS COLLECTED ON 453 PATIENTS, AND THE CASES IN THIS STUDY RANGE FROM FEBRUARY 2005 TO DECEMBER 2013. DURING THE REVIEW OF THE LITERATURE, IT WAS NOT POSSIBLE TO ESTABLISH A SPECIFIC DEVICE DETAIL, PATIENT INFORMATION, AND CURRENTLY NO ADDITIONAL DEVICE INFORMATION IS AVAILABLE; HOWEVER, IT WAS REPORTED THAT 1 PATIENT EXPERIENCED EXCRUCIATING PAIN AND INABILITY TO WALK. AN X-RAY OF THE PATIENT SHOWED FAILURE OF THE METALWORK AND NONUNION OF THE FRACTURE. REVISION SURGERY WAS CONDUCTED BY LONG GAMMA NAIL OSTEOSYNTHESIS WITH ADDITIONAL APPLICATION OF RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN-7 AND AUXILIARY LOCKING PLATE OSTEOSYNTHESIS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
927000 UNKNOWN GAMMA 3 NAIL ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES HSB STRYKER TRAUMA KIEL UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 83 YR Female Required Intervention