FDA Adverse Event Malfunction Summary report: N

ORBERA¿ INTRAGASTRIC BALLOON SYSTEM

MDR report key: 16227585 · Received January 23, 2023

Report

Report Number
3006722112-2023-00013
Event Type
Malfunction
Date Received
January 23, 2023
Report Date
October 27, 2022
Manufacturer
APOLLO ENDOSURGERY, INC
Product Code
LTI
PMA / PMN Number
P140008
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NC, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INITIAL MEDWATCH SUBMITTED TO THE FDA ON 23/JAN/2023. A REVIEW OF THE DEVICE LABELING NOTES THE FOLLOWING: THE CURRENT ORBERA¿ INTRAGASTRIC BALLOON SYSTEM DIRECTIONS FOR USE (DFU) ADDRESSES THE KNOWN AND ANTICIPATED POTENTIAL EVENTS OF NAUSEA; PAIN; BOWEL COMPLICATIONS; EARLY REMOVAL; AND DIARRHEA AS FOLLOWS: THE IGB IS COMPOSED OF A SOFT SILICONE ELASTOMER AND IS EASILY DAMAGED BY INSTRUMENTS OR SHARP OBJECTS. THE IGB MUST BE HANDLED ONLY WITH GLOVED HANDS AND WITH THE INSTRUMENTS RECOMMENDED IN THIS DOCUMENT. THE PHYSIOLOGICAL RESPONSE OF THE PATIENT TO THE PRESENCE OF ORBERA MAY VARY DEPENDING UPON THE PATIENT'S GENERAL CONDITION AND THE LEVEL AND TYPE OF ACTIVITY. THE TYPES AND FREQUENCY OF ADMINISTRATION OF DRUGS OR DIET SUPPLEMENTS AND THE OVERALL DIET OF THE PATIENT MAY ALSO AFFECT THE RESPONSE. EACH PATIENT MUST BE MONITORED CLOSELY DURING THE ENTIRE TERM OF TREATMENT IN ORDER TO DETECT THE DEVELOPMENT OF POSSIBLE COMPLICATIONS. EACH PATIENT SHOULD BE INSTRUCTED REGARDING SYMPTOMS OF DEFLATION, GASTROINTESTINAL OBSTRUCTION, ULCERATION AND OTHER COMPLICATIONS WHICH MIGHT OCCUR, AND SHOULD BE ADVISED TO CONTACT HIS/HER PHYSICIAN IMMEDIATELY UPON THE ONSET OF SUCH SYMPTOMS. PATIENTS WITH AN IGB THAT PRESENT WITH SEVERE ABDOMINAL PAIN THAT HAVE A NEGATIVE ENDOSCOPY AND X-RAY MAY ADDITIONALLY REQUIRE A CT SCAN TO DEFINITIVELY RULE OUT A PERFORATION. PATIENTS MUST BE ADVISED THAT THE IGB IS INTENDED TO BE PLACED FOR 6 MONTHS MAXIMALLY, AT WHICH POINT REMOVAL IS REQUIRED. LONGER PERIODS OF IGB PLACEMENT INCREASE THE RISK OF IGB DEFLATION (A REDUCTION IN SIZE OF THE DEVICE DUE TO LOSS OF SALINE) WHICH CAN LEAD TO INTESTINAL OBSTRUCTION AND RISK FOR DEATH. THE RISK OF THESE EVENTS IS ALSO SIGNIFICANTLY HIGHER WHEN IGBS ARE FILLED TO A LARGER VOLUME THAN INDICATED (GREATER THAN 700CC). IT IS IMPORTANT TO DISCUSS ALL POSSIBLE COMPLICATIONS AND ADVERSE EVENTS WITH YOUR PATIENT. COMPLICATIONS THAT MAY RESULT FROM THE USE OF THIS PRODUCT INCLUDE THE RISKS ASSOCIATED WITH THE MEDICATIONS AND METHODS UTILIZED IN THE ENDOSCOPIC PROCEDURE, THE RISKS ASSOCIATED WITH ANY ENDOSCOPIC PROCEDURE, THE RISKS ASSOCIATED WITH THE ORBERA INTRAGASTRIC BALLOON SPECIFICALLY, AND THE RISKS ASSOCIATED WITH THE PATIENT'S DEGREE OF INTOLERANCE TO A FOREIGN OBJECT PLACED IN THE STOMACH. POSSIBLE COMPLICATIONS: GASTRIC DISCOMFORT, FEELINGS OF NAUSEA AND VOMITING FOLLOWING BALLOON PLACEMENT AS THE DIGESTIVE SYSTEM ADJUSTS TO THE PRESENCE OF THE BALLOON. CONTINUING NAUSEA AND VOMITING. THIS COULD RESULT FROM DIRECT IRRITATION OF THE LINING OF THE STOMACH OR AS A RESULT OF THE BALLOON BLOCKING THE OUTLET OF THE STOMACH. IT IS EVEN THEORETICALLY POSSIBLE THAT THE BALLOON COULD PREVENT VOMITING (NOT NAUSEA OR RETCHING) BY BLOCKING THE INLET TO THE STOMACH FROM THE ESOPHAGUS. ABDOMINAL OR BACK PAIN, EITHER STEADY OR CYCLIC GASTROESOPHAGEAL REFLUX. INSUFFICIENT OR NO WEIGHT LOSS. ADDITIONAL INFORMATION: THE DEVICE HAS NOT BEEN RETURNED FOR ANALYSIS AND ATTEMPTS TO GATHER MORE INFORMATION FROM THE REPORTER IS NOT VISIBLE AS THIS IS A LITERATURE REVIEW, AND THE AUTHOR DOES NOT HAVE THE INFORMATION FOR THE DEVICE. THE INVESTIGATOR DETERMINED A DEVICE HISTORY RECORD (DHR) REVIEW IS NOT POSSIBLE.

Description of Event or Problem · 0

PATIENT HAD SYMPTOMS OF DIARRHEA, ABDOMINAL PAIN, AND NAUSEA. THE BALLOON WAS REMOVED DUE TO THE PATIENT REACHED HIS WEIGHT GOAL. BALLOON WAS EMOVED SUCCESSFULLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
568888 ORBERA¿ INTRAGASTRIC BALLOON SYSTEM INTRAGASTRIC BALLOON SYSTEM LTI APOLLO ENDOSURGERY, INC

Patients

Seq Age Sex Outcome Treatment
1 61 YR Male