FDA Adverse Event Injury Summary report: N

HEMOLUNG RAS

MDR report key: 16200017 · Received January 18, 2023

Report

Report Number
3009763347-2023-00047
Event Type
Injury
Date Received
January 18, 2023
Date of Event
July 20, 2019
Report Date
January 18, 2023
Manufacturer
ALUNG TECHNOLOGIES, INC.
Product Code
QOH
UDI-DI
00850046004346
PMA / PMN Number
DEN210006
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

PATIENT INFORMATION WAS NOT PROVIDED. ALUNG TECHNOLOGIES, INC. MANUFACTURES THE HEMOLUNG RAS AND CATHETER. THE INCIDENT OCCURRED IN ALBANY, NEW YORK. MEDICAL INTERVENTION WAS REQUIRED TO PREVENT FURTHER PATIENT INJURY. ALUNG TECHNOLOGIES, INC. RECEIEVED A REPORT OF A PATIENT EXPERIENCING ANEMIA DURING HEMOLUNG THERAPY. A BLOOD TRANSFUSION WAS REQUIRED. THE DATA LOG FROM HEMOLUNG THERAPY HAS BEEN RETRIEVED AND REVIEWED BY BOTH CLINICAL AND SOFTWARE ENGINEERING STAFF. DURING HEMOLUNG THERAPY, A 102 ERROR OCCURRED IN WHICH THE O2 SENSOR VALUE WAS GREATER THAN 24%. THE CONTROLLER SOFTWARE OPERATED AS INTENDED BY STOPPING THE PUMP. TECHNICAL SUPPORT WAS PROVIDED TO THE CLINICAL STAFF IN WHICH THEY POWER CYCLED DEVICE AND CHOSE TO CONTINUE THE HEMOLUNG THERAPY AT THEIR DISCRETION. NO ABNORMALITIES WERE NOTED WITHIN THE CO2 REMOVAL AND BLOOD FLOW GRAPHS. HEMOLUNG THERAPY WAS PROVIDED AS INTENDED. IT IS NOTED THAT THIS ALARM HAS NO CORRELATION TO ANEMIA IN THIS SUBJECT AND IS UNRELATED. NO CAPA WAS OPENED BECAUSE OF THIS EVENT. ANEMIA IS A KNOWN POSSIBLE OCCURRENCE WITH EXTRACORPOREAL HEMOLUNG THERAPY. REVIEW OF THE CONTROLLER DATA LOG SHOWS THAT HEMOLUNG THERAPY WAS PROVIDED AS INTENDED. ALUNG TECHNOLOGIES, INC. WILL CONTINUE TO MONITOR ANY ISSUES AS THEY ARE REPORTED. THIS MDR IS BEING FILED IN RESPONSE TO A RETROSPECTIVE VIEW OF ALL ALUNG TECHNOLOGIES, INC. COMPLAINTS, WHICH IDENTIFIED THAT THE REPORTING DECISION FOR THIS COMPLAINT WAS NOT CORRECT. THIS MDR IS BEING FILED RETROSPECTIVELY TO CORRECT THE ERROR IN THE REPORTING DECISION.

Description of Event or Problem · 0

ALUNG TECHNOLOGIES, INC. RECEIEVED A REPORT OF A PATIENT EXPERIENCING ANEMIA DURING HEMOLUNG THERAPY. A BLOOD TRANSFUSION WAS REQUIRED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
406344 HEMOLUNG RAS EXTRACORPOREAL SYSTEM FOR CARBON DIOXIDE REMOVAL QOH ALUNG TECHNOLOGIES, INC. HL-CR4-01-000 00850046004346

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention| L