MEDTRONIC NAVIGATION
Report
- Report Number
- 1723170-2023-00060
- Event Type
- Injury
- Date Received
- January 13, 2023
- Date of Event
- February 21, 2022
- Report Date
- January 13, 2023
- Manufacturer
- MEDTRONIC NAVIGATION, INC
- Product Code
- HAW
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IL, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
PATIENT AGE IS THE MEAN VALUE OF PATIENTS IN THE STUDY. PATIENT GENDER IS THE MAJORITY VALUE OF PATIENT IN THE STUDY. A4) PATIENT WEIGHT NOT AVAILABLE FROM THE SITE. EVENT DATE IS THE ONLINE ACCEPTED DATE OF THE LITERATURE ARTICLE. DEVICE LOT NUMBER, OR SERIAL NUMBER, UNAVAILABLE. 510(K) IS DEPENDENT UPON THE DEVICE MODEL NUMBER AND THEREFORE, UNAVAILABLE. NO PARTS HAVE BEEN RECEIVED BY THE MANUFACTURER FOR EVALUATION. H4) DEVICE MANUFACTURING DATE IS DEPENDENT ON LOT NUMBER/SERIAL NUMBER, THEREFORE, UNAVAILABLE. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
NIE, J.Z., WEBER, M.W., REVELT, N.J., NORDMANN, N.J., WATSON, V.L., NIE, J.W., MENEZES, S.A., DELFINO, K., COZZENS, J.W., ESPINOSA, J.A., AMIN, D., ACAKPO-SATCHIVI, L. COMPARISON OF USING INTRAOPERATIVE COMPUTED TOMOGRAPHYEBASED 3-DIMENSIONAL NAVIGATION AND FLUOROSCOPY IN ANTERIOR CERVICAL DISKECTOMY AND FUSION FOR CERVICAL SPONDYLOSIS. WORLD NEUROSURG. 2022. 161 (E740-E747). HTTPS://DOI.ORG /10.1016/J.WNEU.2022.02.089 - OBJECTIVE: ANTERIOR CERVICAL DISKECTOMY AND FUSION (ACDF) IS A HIGHLY SUCCESSFUL PROCEDURE TO TREAT SPINAL CORD OR NERVE ROOT COMPRESSION; HOWEVER, COMPLICATIONS CAN STILL OCCUR. WITH ADVANCEMENTS IN IMAGING, 3-DIMENSIONAL (3D) RECONSTRUCTION ALLOWS REAL-TIME INSTRUMENT TRACKING IN A SURGICAL FIELD RELATIVE TO THE PATIENT¿S ANATOMY. HERE, WE COMPARE PLATE POSITIONING AND SHORT-TERM OUTCOMES WHEN USING 3D NAVIGATION TO FLUOROSCOPY IN ACDF FOR DEGENERATIVE SPINE DISEASE. - METHODS: ALL ACDFS FOR CERVICAL SPONDYLOSIS PERFORMED BY 6 SURGEONS AT A SINGLE CENTER BETWEEN 2010 AND 2018 WERE INCLUDED. ACDFS WERE DIVIDED INTO THOSE PERFORMED USING 3D NAVIGATION OR FLUOROSCOPY. RECORDS WERE ASSESSED FOR PATIENT DEMOGRAPHICS, AMERICAN SOCIETY OF ANESTHESIOLOGY SCORE, NUMBER OF OPERATED INTERSPACES, OPERATIVE TIME, LENGTH OF STAY, PERIOPERATIVE COMPLICATIONS, AND 90-DAY READMISSIONS. POSTOPERATIVE IMAGES WERE REVIEWED FOR LATERAL AND ANGULAR PLATE DEVIATIONS. - RESULTS: A TOTAL OF 193 ACDFS PERFORMED WITH 3D NAVIGATION AND 728 PERFORMED WITH FLUOROSCOPY WERE INCLUDED. AFTER CONTROLLING FOR DEMOGRAPHICS AND SURGICAL CHARACTERISTICS, USING 3D NAVIGATION WAS ASSOCIATED WITH LESS LATERAL PLATE DEVIATION (P [ 0.048) AND LONGER OPERATIVE TIMES PER INTERSPACE (P <(><<)> 0.001) BUT WAS NOT ASSOCIATED WITH ANGULAR PLATE DEVIATION (P [ 0.724), LENGTH OF STAY (P [ 0.393), PERIOPERATIVE COMPLICATIONS (P [ 0.844), AND 90-DAY READMISSIONS (P [ 0.539). - CONCLUSIONS: USING 3D NAVIGATION IN ACDF FOR DEGENERATIVE DISEASE IS ASSOCIATED WITH SLIGHTLY MORE MIDLINE PLATE POSITIONING AND COMPARABLE SHORT-TERM OUTCOMES AS USING FLUOROSCOPY AND CAN BE A SUITABLE ALTERNATIVE. ADVANTAGES OF USING THIS TECHNOLOGY, SUCH AS IMPROVED VISUALIZATION OF ANATOMY, SHOULD BE WEIGHED AGAINST DISADVANTAGES, SUCH AS INCREASED OPERATIVE TIME, ON A PER-PATIENT BASIS. REPORTED EVENTS: PATIENTS WITH 90-DAY READMISSION: 4 PATIENTS WITH PAIN 2 PATIENTS WITH NEUROLOGIC DEFICIT 3 PATIENTS WITH SURGICAL SITE INFECTION 1 PATIENT WITH WOUND DEHISCENCE 5 PATIENTS WITH HARDWARE FAILURE 4 PATIENTS WITH DYSPHAGIA 1 PATIENT WITH EPIDURAL ABSCESS 2 PATIENTS WITH A HEMATOMA 1 PATIENT WITH AN INFECTION NOT ON THE SURGICAL SITE 3 PATIENTS WITH WEAKNESS 1 PATIENT WITH ASPIRATION 1 PATIENT WITH URINARY RETENTION 3 PATIENTS WITH CARDIAC PROBLEMS 2 PATIENTS WITH PULMONARY PROBLEMS 2 PATIENTS WITH GASTROINTESTINAL PROBLEMS 2 PATIENTS WITH PSYCHIATRIC PROBLEMS 1 PATIENTS WITH TRAUMA SEE ATTACHED LITERATURE ARTICLE
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1963734 | MEDTRONIC NAVIGATION | NEUROLOGICAL STEREOTAXIC INSTRUMENT | HAW | MEDTRONIC NAVIGATION, INC | UNK_NAV_SYS |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 60 YR | Female | Required Intervention |