BD SMARTSITE 13MM VIAL ACCESS DEVICE
Report
- Report Number
- 9616066-2022-02060
- Event Type
- Malfunction
- Date Received
- December 23, 2022
- Date of Event
- December 6, 2022
- Report Date
- January 26, 2023
- Manufacturer
- SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
- Product Code
- FPA
- UDI-DI
- 27613203013851
- PMA / PMN Number
- K970485
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- PA, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES, D10: RETURNED TO MANUFACTURER ON: 27-DEC-2022 H6: INVESTIGATION SUMMARY FOUR SAMPLES OF MATERIAL NUMBER 2203E WAS SUBMITTED FOR QUALITY INVESTIGATION. THE CUSTOMER COMPLAINT OF PACKAGING ISSUE WAS VERIFIED BY VISUAL INSPECTION AND EVALUATION. THE SAMPLES SUBMITTED WERE SUBJECTED TO VISUAL INSPECTION UNDER MAGNIFICATION. THE SAMPLES SUBMITTED SHOWED SIGNS OF DAMAGE TO THE CLEAR PLASTIC PACKAGING. THE DAMAGE SEEN WERE HOLES IN THE PACKAGING THAT VARIED IN SHAPE AND SIZES. FURTHER EXAMINATION OF THE ISSUE IN RELATION TO THE PRODUCT SHOWED THAT THE DAMAGE IN THE PACKAGING WAS ALWAYS ON THE SIDE OF THE PACKAGING WHERE THE LARGE OPENING SIDE OF THE PRODUCT WOULD BE LOCATED. ADDITIONAL EVALUATION WAS CONDUCTED IN ORDER TO DETERMINE IF THE PLASTIC PACKAGING COULD BE PUNCTURED BY THE INTERNAL SPIKE OF THE PRODUCT. ALTHOUGH THE SPIKE IS SHARP ENOUGH TO PUNCTURE THE PLASTIC PACKAGING, IT DID NOT SEEM FEASIBLE THAT THE SPIKE PUNCTURED THE PLASTIC PACKAGING BECAUSE IN ORDER FOR THE PLASTIC PACKAGING TO BE DAMAGED BY THE SPIKE, IT WOULD HAVE TO FORCEFULLY PUSHED INTO THE SPIKE, STRETCHING THE PLASTIC PACKAGING MORE THAN IT WOULD BE STRETCHED IN A NORMAL USE SITUATION. FURTHER INVESTIGATION INTO THE TYPES OF HOLES SEEN, SHOWED THAT SOME OF THE HOLES LOOKED TO BE LONGER IN LENGTH AND REPRESENTED MORE LIKE TEARS IN THE PACKAGING RATHER THAN HOLES. WITH THIS IN MIND, A TEST WAS DONE TO SEE IF STACKING THE PRODUCT IN THE PACKAGING AND PRESSING DOWN ON THE STACK, WOULD CAUSE A TEAR IN THE PLASTIC PACKAGING. THE TEST WAS SUCCESSFUL, AND A TEAR WAS CREATED IN THE PACKAGING THAT WAS SIMILAR TO THE TEARS SEEN IN THE SAMPLES EXAMINED. A DEVICE HISTORY RECORD REVIEW FOR MODEL 2203E LOT NUMBER 22075477 WAS PERFORMED. THERE WERE NO QUALITY NOTIFICATIONS ISSUED FOR THE FAILURE MODE REPORTED BY THE CUSTOMER DURING THE PRODUCTION BUILD OF THIS SET. BASED ON THE FINDINGS OF THE INVESTIGATION, THE PROBABLE ROOT CAUSE OF THE ISSUE LIES IN THE PACKAGING OF THE PRODUCT.
DATE OF EVENT IS UNKNOWN; AWARENESS DATE HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.
IT WAS REPORTED WHILE USING BD SMARTSITE 13MM VIAL ACCESS DEVICE THE PACKAGE WAS DAMAGED. THIS OCCURRED TWICE. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: AT A HIGH LEVEL, THE PACKAGING HAS A HOLE/ PUNCTURE IN THE OVERWRAP.
IT WAS REPORTED WHILE USING BD SMARTSITE 13MM VIAL ACCESS DEVICE THE PACKAGE WAS DAMAGED. THIS OCCURRED TWICE. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: AT A HIGH LEVEL, THE PACKAGING HAS A HOLE/ PUNCTURE IN THE OVERWRAP.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2654089 | BD SMARTSITE 13MM VIAL ACCESS DEVICE | INTRAVASCULAR ADMINISTRATION SET | FPA | SISTEMAS MEDICOS ALARIS, S.A. DE C.V. | 2203E | 22075477 | 27613203013851 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |