FDA Adverse Event Malfunction Summary report: N

OPTIFLOW + ADULT NASAL CANNULA

MDR report key: 16030927 · Received December 21, 2022

Report

Report Number
9611451-2022-01236
Event Type
Malfunction
Date Received
December 21, 2022
Report Date
November 23, 2022
Manufacturer
FISHER & PAYKEL HEALTHCARE LTD
Product Code
BTT
PMA / PMN Number
K162553
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

(B)(4). PRODUCT BACKGROUND: THE OPT944 OPTIFLOW + ADULT NASAL CANNULA IS A NASAL CANNULA PATIENT INTERFACE FOR DELIVERY OF HUMIDIFIED RESPIRATORY GASES, INCLUDING THOSE WHO ARE RECEIVING NASAL HIGH FLOW THERAPY (NHF). OPTIFLOW + INTERFACES ARE DESIGNED FOR USE WITH THE AIRVO 2 SERIES OF HUMIDIFICATION DEVICES. NHF THERAPY IS INTENDED FOR USE WITH SPONTANEOUSLY BREATHING PATIENTS WHO WOULD BENEFIT FROM RECEIVING HIGH FLOW WARMED AND HUMIDIFIED RESPIRATORY GASES NHF THERAPY SHOULD NOT BE USED FOR LIFE SUPPORT PURPOSES, AND APPROPRIATE PATIENT MONITORING MUST BE USED AT ALL TIMES. FISHER & PAYKEL HEALTHCARE (F&P) IS CURRENTLY IN THE PROCESS OF COMPLETING OUR INVESTIGATION. WE WILL PROVIDE A FOLLOW UP REPORT UPON COMPLETION OF OUR INVESTIGATION.

Additional Manufacturer Narrative · 0

(B)(4). PRODUCT BACKGROUND: THE OPT944 OPTIFLOW + ADULT NASAL CANNULA IS A NASAL CANNULA PATIENT INTERFACE FOR DELIVERY OF HUMIDIFIED RESPIRATORY GASES, INCLUDING THOSE WHO ARE RECEIVING NASAL HIGH FLOW THERAPY (NHF). OPTIFLOW + INTERFACES ARE DESIGNED FOR USE WITH THE AIRVO 2 SERIES OF HUMIDIFICATION DEVICES. NHF THERAPY IS INTENDED FOR USE WITH SPONTANEOUSLY BREATHING PATIENTS WHO WOULD BENEFIT FROM RECEIVING HIGH FLOW WARMED AND HUMIDIFIED RESPIRATORY GASES NHF THERAPY SHOULD NOT BE USED FOR LIFE SUPPORT PURPOSES, AND APPROPRIATE PATIENT MONITORING MUST BE USED AT ALL TIMES. METHOD: THE COMPLAINT OPT944 OPTIFLOW + ADULT NASAL CANNULA WAS NOT RETURNED TO FISHER & PAYKEL HEALTHCARE (F&P) FOR EVALUATION. OUR INVESTIGATION IS BASED ON THE INFORMATION PROVIDED BY THE CUSTOMER, PREVIOUS INVESTIGATIONS OF SIMILAR COMPLAINTS, AND OUR KNOWLEDGE OF THE PRODUCT. RESULTS: THE CUSTOMER HAS STATED THAT THE TUBING OF AN OPT944 OPTIFLOW + ADULT NASAL CANNULA WAS DAMAGED. CONCLUSION: OUR INVESTIGATION WAS UNABLE TO DETERMINE THE CAUSE OF THE REPORTED DAMAGE. BASED ON OUR KNOWLEDGE OF THE PRODUCT, THE REPORTED DAMAGE IS LIKELY TO HAVE BEEN CAUSED BY THE TUBING BEING SUBJECTED TO EXCESSIVE FORCE DURING USE. FISHER AND PAYKEL HEALTHCARE'S MANUFACTURING CONTROLS FOR THE OPTIFLOW + TUBING INCLUDE INSPECTIONS DURING PRODUCTION FOR VISUAL DEFECTS INCLUDING CRACKS, TEARS, MOULDING DEFECTS, CONTAMINATION, INCLUSIONS, DISCOLORATION AND STRETCHING OR DEFORMATION. THE SUBJECT OPT944 OPTIFLOW + ADULT NASAL CANNULA WOULD HAVE MET THE REQUIRED SPECIFICATIONS. THE USER INSTRUCTIONS WHICH ACCOMPANY THE OPT944 OPTIFLOW + ADULT NASAL CANNULA SHOW IN PICTORIAL FORMAT THE CORRECT PLACEMENT AND FITTING OF THE CANNULA, INCLUDING ENSURING THE HEADSTRAP CLIP AND THE TUBING CLIP ARE APPROPRIATELY ATTACHED. THE USER INSTRUCTIONS ALSO WARN: "ENSURE HEAD STRAP CLIP IS ATTACHED, TO PREVENT CANNULA FROM BEING PULLED OUT OF THE NARES." "CANNULA CAN BECOME UNATTACHED IF NOT USED WITH THE HEAD STRAP CLIP." "ATTACH TUBING CLIP TO CLOTHING/BEDDING TO PREVENT CANNULA FROM PULLING OFF FACE." "APPROPRIATE PATIENT MONITORING MUST BE USED AT ALL TIMES. FAILURE TO MONITOR THE PATIENT MAY RESULT IN LOSS OF THERAPY, SERIOUS INJURY OR DEATH." "DO NOT CRUSH OR STRETCH TUBE, TO PREVENT LOSS OF THERAPY." "FAILURE TO USE THE SET-UP DESCRIBED ABOVE CAN COMPROMISE PERFORMANCE AND AFFECT PATIENT SAFETY."

Description of Event or Problem · 0

A HEALTHCARE FACILITY IN MAASTRICHT REPORTED THAT THE TUBING OF AN OPT944 OPTIFLOW + ADULT NASAL CANNULA WAS FOUND DAMAGED. THERE WAS NO PATIENT CONSEQUENCE.

Description of Event or Problem · 0

A HEALTHCARE FACILITY IN MAASTRICHT REPORTED THAT THE TUBING OF AN OPT944 OPTIFLOW + ADULT NASAL CANNULA WAS FOUND DAMAGED. THERE WAS NO REPORTED PATIENT INVOLVEMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2917769 OPTIFLOW + ADULT NASAL CANNULA BTT BTT FISHER & PAYKEL HEALTHCARE LTD OPT944

Patients

Seq Age Sex Outcome Treatment
1 Unknown