FDA Adverse Event Injury Summary report: N

PROXIMAL HUMERUS, RIGHT, 9X160MM

MDR report key: 16012190 · Received December 20, 2022

Report

Report Number
0009613350-2022-00640
Event Type
Injury
Date Received
December 20, 2022
Date of Event
November 1, 2022
Report Date
January 31, 2023
Manufacturer
ZIMMER SWITZERLAND MANUFACTURING GMBH
Product Code
HSB
PMA / PMN Number
K181827
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

(B)(4). REPORT SOURCE: FOREIGN: JAPAN. CONCOMITANT MEDICAL PRODUCTS: BLUNT TIP SCREW, 4X38MM #ITEM 47248603840 #LOT 3081898. BLUNT TIP SCREW, 4X40MM #ITEM 47248604040 #LOT 3086986. BLUNT TIP SCREW, 4X42MM #ITEM 47248604240 #LOT 3082110. ANN PH NAIL RT 9X160MM #ITEM 47-2496-160-09 #LOT 3083730. ANN CORT BONE SCREW 4 X 24MM #ITEM 47-2486-124-40 #LOT 3091458. ANN WASHER SMALL #ITEM 47-2488-000-04 #LOT 3081906. AFFIXUS PH NL CAP 0MM #ITEM 47-2488-010-00 #LOT 3091377. INVESTIGATION OF THIS INCIDENT IS CURRENTLY ONGOING. ONCE THE INVESTIGATION IS COMPLETED, A SUPPLEMENTAL MEDWATCH 3500A WILL BE SUBMITTED. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE ASSOCIATED REPORTS: 0009613350-2022-00641, 0009613350-2022-00642, 0009613350-2022-00643.

Additional Manufacturer Narrative · 0

(B)(4). THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION AND CORRECTED INFORMATION. AS NO PRODUCTS WERE RETURNED, VISUAL AND DIMENSIONAL EVALUATIONS COULD NOT BE PERFORMED. REVIEW OF THE DEVICE HISTORY RECORDS IDENTIFIED NO DEVIATIONS OR ANOMALIES DURING MANUFACTURING. DEVICES ARE USED FOR TREATMENT. THE PRODUCT COMBINATION WAS APPROVED BY ZIMMER BIOMET. THE SURGICAL TECHNIQUE EXPLAINS THAT THE LOCKING OF THE CORELOCK IS DONE USING THE CORELOCK DRIVER WITH TORQUE LIMITING HANDLE. "TURN SLOWLY CLOCKWISE TO TIGHTEN AND ENGAGE THE CORELOCK MECHANISM UNTIL A CLICK IS FELT FROM THE TORQUE LIMITING HANDLE." NO MEDICAL REPORTS WERE PROVIDED. BASED ON THE INVESTIGATION IT COULD BE ASSUMED THAT FURTHER POSSIBLE CONTRIBUTING FACTORS TO THE MIGRATION OF THE SCREW MIGHT BE MULTIFACTORIAL RELATED TO EITHER PATIENT CONDITION, BEHAVIOR OR IMPLANTATION PROCEDURE. IF AND TO WHAT EXTENT ANY OF THESE ASPECTS MAY HAVE INFLUENCED THE MIGRATION OF THE SCREW REMAINS UNKNOWN. AN ADDITIONAL DEEPER INVESTIGATION WAS PERFORMED WHICH IDENTIFIED THE DESIGN LIMITATION OF THE CORELOCK MECHANISM OF THE AFFIXUS NAIL AS A POTENTIAL CONTRIBUTING FACTOR. AS PART OF THE DEEPER INVESTIGATION, A SCIENTIFIC LITERATURE SEARCH WAS CONDUCTED AND A SYSTEMATIC REVIEW OF THE OUTCOME OF INTRAMEDULLARY NAILING FOR ACUTE PROXIMAL HUMERUS FRACTURE SHOWED THAT SCREW MIGRATION AND PERFORATION INTO THE JOINT IS THE SECOND MOST COMMON COMPLICATION FOLLOWING SECONDARY LOSS OF REDUCTION. IN ADDITION, SCIENTIFIC LITERATURE OF COMPETITOR AND PREDICATE DEVICES WERE ASSESSED. THIS REVIEW HAS SHOWN THAT THE AFFIXUS® NATURAL NAIL® PROXIMAL HUMERAL SYSTEM PERFORMS BETTER AND/OR IN EQUAL RANGE IN COMPARISON WITH LEGALLY MARKETED SIMILAR DEVICES. THEREFORE, NO DESIGN CHANGES WERE CONDUCTED. IN CONCLUSION, AS THE CAUSE MAY BE MULTIFACTORIAL AN EXACT ROOT CAUSE COULD NOT BE IDENTIFIED FOR THE MIGRATION OF THE SCREW. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.

Description of Event or Problem · 0

IT WAS REPORTED THAT APPROXIMATELY TWO (2) MONTHS AFTER IMPLANTATION, DURING A ROUTINE POST-OPERATIVE CHECKUP, IT WAS FOUND OUT THAT A PROXIMAL SCREW HAD BACKED OUT FROM THE PROPER POSITION. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2841680 PROXIMAL HUMERUS, RIGHT, 9X160MM ROD, FIXATION, INTRAMEDULLARY HSB ZIMMER SWITZERLAND MANUFACTURING GMBH N/A 3083730

Patients

Seq Age Sex Outcome Treatment
1 Prefer Not To Disclose Other