FDA Adverse Event Injury Summary report: N

DILAPAN-S

MDR report key: 15974941 · Received December 14, 2022

Report

Report Number
3003994796-2022-00001
Event Type
Injury
Date Received
December 14, 2022
Date of Event
June 12, 2019
Report Date
January 4, 2023
Manufacturer
MEDICEM TECHNOLOGY S.R.O.
Product Code
PKN
PMA / PMN Number
K143447
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER
Health Professional
N

Narratives

Description of Event or Problem · 0

THE PATIENT INDICATED FOR TOP (TERMINATION OF PREGNANCY) DUE TO "DEATH FOETUS" UNDERGONE THE PROCEDURE USING THE DILATOR DILAPAN-S ON (B)(6) 2019. DURING THE REMOVAL PROCEDURE WHICH WAS PERFORMED UNDER CRITICAL SITUATION AND LACK OF TIME (URGENT CAESARIAN SECTION THAT OCCURED IN PARALLEL AND REQUIRED PRESENCE OF THE HCP) THE BREAKAGE OF THE DILATOR OCCURED AND A 4,5 CM LONG FRAGMENT (AS ASSESSED BY REPORTER) REMAINED IN THE PATIENT'S UTERUS. THE RESPONSIBLE HCP (HEALTH-CARE PROFFESIONAL) TRIED TO REMOVE THE FRAGMENT, WHICH CAUSED PROLONGATION OF THE TOP PROCEDURE. THE REMOVAL WAS NOT SUCCESSFUL AND THE PATIENT REMAINED IN THE HOSPITAL. NEXT DAY THE PATIENT WAS TRANSPORTED TO A DIFFERENT FACILITY TO REMOVE THE FRAGMENT FROM HER BODY. THE SECOND ATTEMPT WAS NOT SUCCESSFUL, INFECTION IN THE PATIENT'S BODY OCCURED - TREATED WITH ANTIBIOTICS. THE PATIENT REMAINED IN THE HOSPITAL TILL (B)(6) 2019 WHEN SHE WAS DISCHARGED WITH THE FRAGMENT STILL IN THE BODY AND CONTINUING TREATMENT WITH ANTIBIOTICS. THE FRAGMENT WAS REPORTED TO LEAVE THE BODY SPONTANEOUSLY THE 16TH DAY AFTER THE PROCEDURE (ESTIMATED (B)(6) 2019 AS REPORTED BY THE PATIENT). THE PATIENT SUFFERED FROM PERSISTING COMPLICATIONS. THE PROPOSED CONSEQUENCE OF THE INFECTION MAY BE OBSERVED OBSTRUCTION OF RIGHT-SIDE FALLOPIAN TUBE, CAUSING FERTILITY ISSUES. THE CASE HAPPENED IN 2019 HOWEVER THE MANUFACTURER WAS NOT INFORMED ABOUT THE EVENT UNTIL 1ST SEPTEMBER 2022 WHEN THE FIRST MESSAGE OCCURRED BUT CONTAINED NO INFORMATION WHAT HAPPENED. AFTER CONTINUING EFFORT AN OFFICIAL LETTER WITH A DESCRIPTION OF THE CASE FROM HUNGARIAN COURT WAS RECEIVED ON 5TH DECEMBER 2022. THERE IS NO INDICATION OF QUALITY ISSUE, LOT IS NOT KNOWN. DUE TO REPORTED NON-STANDARD CIRCUMSTANCES OF DILATOR(S)' REMOVAL THE MOST LIKELY CAUSE IS USER ERROR.

Description of Event or Problem · 0

THE PATIENT INDICATED FOR TOP (TERMINATION OF PREGNANCY) DUE TO "DEATH FOETUS" UNDERGONE THE PROCEDURE USING THE DILATOR DILAPAN-S ON (B)(6) 2019. DURING THE REMOVAL PROCEDURE WHICH WAS PERFORMED UNDER CRITICAL SITUATION AND LACK OF TIME (URGENT CAESARIAN SECTION THAT OCCURED IN PARALLEL AND REQUIRED PRESENCE OF THE HCP) THE BREAKAGE OF THE DILATOR OCCURED AND A 4,5 CM LONG FRAGMENT (AS ASSESSED BY REPORTER) REMAINED IN THE PATIENT'S UTERUS. THE RESPONSIBLE HCP (HEALTH-CARE PROFFESIONAL) TRIED TO REMOVE THE FRAGMENT, WHICH CAUSED PROLONGATION OF THE TOP PROCEDURE. THE REMOVAL WAS NOT SUCCESSFUL AND THE PATIENT REMAINED IN THE HOSPITAL. NEXT DAY THE PATIENT WAS TRANSPORTED TO A DIFFERENT FACILITY TO REMOVE THE FRAGMENT FROM HER BODY. THE SECOND ATTEMPT WAS NOT SUCCESSFUL, INFECTION IN THE PATIENT'S BODY OCCURED - TREATED WITH ANTIBIOTICS. THE PATIENT REMAINED IN THE HOSPITAL TILL (B)(6) 2019 WHEN SHE WAS DISCHARGED WITH THE FRAGMENT STILL IN THE BODY AND CONTINUING TREATMENT WITH ANTIBIOTICS. THE FRAGMENT WAS REPORTED TO LEAVE THE BODY SPONTANEOUSLY THE 16TH DAY AFTER THE PROCEDURE (ESTIMATED (B)(6) 2019 AS REPORTED BY THE PATIENT). THE PATIENT SUFFERED FROM PERSISTING COMPLICATIONS. THE PROPOSED CONSEQUENCE OF THE INFECTION MAY BE OBSERVED OBSTRUCTION OF RIGHT-SIDE FALLOPIAN TUBE, CAUSING FERTILITY ISSUES. AS DESCRIBED IN THE PROVIDED TRANSCRIPT OF THE HUNGARIAN COURT THERE EXISTS A HYPOTETICAL JUSTIFICATION OF THE ISSUE. EXAMINATION OF THE PATIENT PERFORMED A FEW YEARS AFTER THE EVENT (2022) REVEALED SUSPECT FINDING OF "FALSE ROUTE" POSSIBLE BEING CAUSED BY MISSPLACEMENT OF THE ROD. HOWEVER THERE IS NO TANGIBLE EVIDENCE OF RELATIONSHIP BETWEEN THE REPORTED EVENT AND THIS FINDING. DUE TO REPORTED NON-STANDARD CIRCUMSTANCES OF DILATOR(S)' REMOVAL (AND SUSPECTED INCORRECT INSPERTION) THE MOST LIKELY CAUSE IS USER ERROR. THE FRAGMENTATION AND/OR ROD DISPLACEMENT IS EXPECTED (= DESCRIBED IN THE IFU) AND PROPERLY EVALUATED IN THE MANUFACTURER'S RISK ANALYSIS AS A HYPOTHETICAL HARM TO THE PATIENT HOWEVER REMOTE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2051301 DILAPAN-S DILATOR, CERVICAL, SYNTHETIC, OSMOTIC PKN MEDICEM TECHNOLOGY S.R.O.

Patients

Seq Age Sex Outcome Treatment
1 Female Required Intervention| H| O