FDA Adverse Event Malfunction Summary report: N

BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET

MDR report key: 15939609 · Received December 8, 2022

Report

Report Number
1710034-2022-00765
Event Type
Malfunction
Date Received
December 8, 2022
Date of Event
November 15, 2022
Report Date
January 23, 2023
Manufacturer
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
Product Code
JKA
UDI-DI
50382903673242
PMA / PMN Number
K030573
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NH, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Additional Manufacturer Narrative · 0

H.6. INVESTIGATION SUMMARY: BD RECEIVED 62 SEALED REPRESENTATIVE SAMPLES FROM LOT #2153246 FOR INVESTIGATION. THE CUSTOMER SAMPLES VISUALLY INSPECTED AND FUNCTIONALLY TESTED AND NO ISSUES RELATING TO LEAKAGE OR AIR BUBBLES WERE OBSERVED. BASED ON A REVIEW OF THE DEVICE HISTORY RECORD FOR THE INCIDENT LOT, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET. THERE WERE NO RELATED QUALITY ISSUES DURING MANUFACTURING OF THE PRODUCT. THIS COMPLAINT IS UNABLE TO BE CONFIRMED FOR THE INDICATED FAILURE MODE OF LEAKING. BD WAS NOT ABLE TO IDENTIFY A ROOT CAUSE FOR THE INDICATED FAILURE MODE. H3 OTHER TEXT : SEE H.10

Description of Event or Problem · 0

IT WAS REPORTED WHEN USING THE BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET THERE WAS BLOOD LEAKAGE OR OTHER SAMPLE LEAKAGE FROM THE DEVICE OTHER THAN THE INSERTION SITE OR NEEDLE TIP AND AIR BUBBLES IN THE GEL. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER. THE CUSTOMER STATED: THERE IS LEAKING AROUND THE HUB AND AIR IS BACKED UP IN THE TUBING.

Description of Event or Problem · 0

IT WAS REPORTED WHEN USING THE BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET THERE WAS BLOOD LEAKAGE OR OTHER SAMPLE LEAKAGE FROM THE DEVICE OTHER THAN THE INSERTION SITE OR NEEDLE TIP AND AIR BUBBLES IN THE GEL. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER. THE CUSTOMER STATED: THERE IS LEAKING AROUND THE HUB AND AIR IS BACKED UP IN THE TUBING

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2586558 BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET BLOOD SPECIMEN COLLECTION DEVICE JKA BECTON DICKINSON INFUSION THERAPY SYSTEMS INC. 367324 2153246 50382903673242

Patients

Seq Age Sex Outcome Treatment
1 Unknown