FDA Adverse Event Malfunction Summary report: N

POWERLED

MDR report key: 15813315 · Received November 17, 2022

Report

Report Number
9710055-2022-00477
Event Type
Malfunction
Date Received
November 17, 2022
Date of Event
November 15, 2022
Report Date
November 17, 2022
Manufacturer
MAQUET SAS
Product Code
FSY
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AU
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL INFORMATION WILL BE PROVIDED FOLLOWING THE CONCLUSION OF THE INVESTIGATION. DEVICE NOT RETURNED TO MANUFACTURER.

Additional Manufacturer Narrative · 0

GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF SURGICAL LIGHTS - POWERLED. AS IT WAS STATED, CAMERA HEAD BROKEN OFF. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE IN ABUNDANCE OF CAUTION AS ANY PARTS FALLING OFF INTO STERILE FIELD MAY LEAD TO RISK OF CONTAMINATION. ACCORDING TO THE INFORMATION PROVIDED BY GETINGE TECHNICIAN, CUSTOMER¿S MEDICAL ENGINEER WOULD ORDER AND ASSEMBLE THE BROKEN PARTS THEMSELVES. IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE SURGICAL LIGHT DID NOT MEET ITS SPECIFICATION AS BROKEN OFF CAMERA HEAD COULD BE TREATED AS TECHNICAL DEFICIENCY AND IN THIS WAY THE DEVICE CONTRIBUTED TO THE EVENT. THERE IS NO INFORMATION AVAILABLE WHETHER THE DEVICE WAS OR WAS NOT BEING USED FOR PATIENT TREATMENT. DURING THE INVESTIGATION, IT WAS FOUND THAT IN THE PAST THE REPORTED SCENARIO HAS NEVER LEAD TO SERIOUS INJURY NOR DEATH. COMPARING THE NUMBER OF CLAIMED DEVICES TO THE INSTALL BASE, WE CONCLUDE THAT THE FAILURE RATIO IS LOW FOR BROKEN OFF CAMERA HEAD. A ROOT CAUSE ANALYSIS WAS PERFORMED BY SUBJECT MATTER EXPERT AT MANUFACTURING SITE. AS STATED, THE SEPARATION OF THE CAMERA HAS BEEN CAUSED BY A TEARING OF THE BASE FIXING HOLE, DUE TO REPETITIVE STRESSES DURING THE MANIPULATION OF THE CAMERA. THE INVOLVED PLASTIC PART 567801057 IN PPS FORTRON HAS BEEN REPLACED BY A STEEL PART 567801181 IN JANUARY 2011 UNDER MODIFICATION FILE #E090520. THE KIT 367265555, INCLUDING THE BASE 567801181 IN STEEL WAS AVAILABLE FROM JULY 2010. MAQUET SAS RECOMMENDS UPDATING THE SIMILAR CAMERAS, IN PREVENTIVE MEASURE, IN THIS FACILITY. CURRENTLY THE CAMERAS # 567203945, 567203944, 567501246, 567501248 ARE NOT ANY MORE DISTRIBUTED. FROM JANUARY 2011 ALL THE CAMERAS SUPPLIED ARE EQUIPPED WITH THE STEEL BASE. WE BELIEVE THAT ALL REMAINING DEVICES ARE PERFORMING CORRECTLY IN THE MARKET. GIVEN THE CIRCUMSTANCES, WE SHALL CONTINUE TO MONITOR FOR ANY FURTHER EVENTS OF THIS NATURE AND DO NOT PROPOSE ANY FURTHER ACTION AT THIS TIME.

Description of Event or Problem · 0

ON (B)(6) 2022 GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF SURGICAL LIGHTS - POWERLED. AS IT WAS STATED, CAMERA HEAD BROKEN OFF. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE IN ABUNDANCE OF CAUTION AS ANY PARTS FALLING OFF INTO STERILE FIELD MAY LEAD TO RISK OF CONTAMINATION.

Description of Event or Problem · 0

MANUFACTURER'S REFERENCE NUMBER (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
171947 POWERLED LIGHT, SURGICAL, CEILING MOUNTED FSY MAQUET SAS

Patients

Seq Age Sex Outcome Treatment
1 Unknown