POWERLED
Report
- Report Number
- 9710055-2022-00477
- Event Type
- Malfunction
- Date Received
- November 17, 2022
- Date of Event
- November 15, 2022
- Report Date
- November 17, 2022
- Manufacturer
- MAQUET SAS
- Product Code
- FSY
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AU
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
ADDITIONAL INFORMATION WILL BE PROVIDED FOLLOWING THE CONCLUSION OF THE INVESTIGATION. DEVICE NOT RETURNED TO MANUFACTURER.
GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF SURGICAL LIGHTS - POWERLED. AS IT WAS STATED, CAMERA HEAD BROKEN OFF. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE IN ABUNDANCE OF CAUTION AS ANY PARTS FALLING OFF INTO STERILE FIELD MAY LEAD TO RISK OF CONTAMINATION. ACCORDING TO THE INFORMATION PROVIDED BY GETINGE TECHNICIAN, CUSTOMER¿S MEDICAL ENGINEER WOULD ORDER AND ASSEMBLE THE BROKEN PARTS THEMSELVES. IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE SURGICAL LIGHT DID NOT MEET ITS SPECIFICATION AS BROKEN OFF CAMERA HEAD COULD BE TREATED AS TECHNICAL DEFICIENCY AND IN THIS WAY THE DEVICE CONTRIBUTED TO THE EVENT. THERE IS NO INFORMATION AVAILABLE WHETHER THE DEVICE WAS OR WAS NOT BEING USED FOR PATIENT TREATMENT. DURING THE INVESTIGATION, IT WAS FOUND THAT IN THE PAST THE REPORTED SCENARIO HAS NEVER LEAD TO SERIOUS INJURY NOR DEATH. COMPARING THE NUMBER OF CLAIMED DEVICES TO THE INSTALL BASE, WE CONCLUDE THAT THE FAILURE RATIO IS LOW FOR BROKEN OFF CAMERA HEAD. A ROOT CAUSE ANALYSIS WAS PERFORMED BY SUBJECT MATTER EXPERT AT MANUFACTURING SITE. AS STATED, THE SEPARATION OF THE CAMERA HAS BEEN CAUSED BY A TEARING OF THE BASE FIXING HOLE, DUE TO REPETITIVE STRESSES DURING THE MANIPULATION OF THE CAMERA. THE INVOLVED PLASTIC PART 567801057 IN PPS FORTRON HAS BEEN REPLACED BY A STEEL PART 567801181 IN JANUARY 2011 UNDER MODIFICATION FILE #E090520. THE KIT 367265555, INCLUDING THE BASE 567801181 IN STEEL WAS AVAILABLE FROM JULY 2010. MAQUET SAS RECOMMENDS UPDATING THE SIMILAR CAMERAS, IN PREVENTIVE MEASURE, IN THIS FACILITY. CURRENTLY THE CAMERAS # 567203945, 567203944, 567501246, 567501248 ARE NOT ANY MORE DISTRIBUTED. FROM JANUARY 2011 ALL THE CAMERAS SUPPLIED ARE EQUIPPED WITH THE STEEL BASE. WE BELIEVE THAT ALL REMAINING DEVICES ARE PERFORMING CORRECTLY IN THE MARKET. GIVEN THE CIRCUMSTANCES, WE SHALL CONTINUE TO MONITOR FOR ANY FURTHER EVENTS OF THIS NATURE AND DO NOT PROPOSE ANY FURTHER ACTION AT THIS TIME.
ON (B)(6) 2022 GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF SURGICAL LIGHTS - POWERLED. AS IT WAS STATED, CAMERA HEAD BROKEN OFF. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE IN ABUNDANCE OF CAUTION AS ANY PARTS FALLING OFF INTO STERILE FIELD MAY LEAD TO RISK OF CONTAMINATION.
MANUFACTURER'S REFERENCE NUMBER (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 171947 | POWERLED | LIGHT, SURGICAL, CEILING MOUNTED | FSY | MAQUET SAS |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |