FDA Adverse Event Malfunction Summary report: N

FLOW 20 PERCUTANEOUS ENDOSCOPIC GASTROSTOMY SET - PULL

MDR report key: 15804316 · Received November 16, 2022

Report

Report Number
1037905-2022-00639
Event Type
Malfunction
Date Received
November 16, 2022
Date of Event
March 24, 2022
Report Date
November 16, 2022
Manufacturer
WILSON-COOK MEDICAL INC
Product Code
KNT
PMA / PMN Number
K920703
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

CHA BH, PARK MJ, BAEG JY, ET AL. HOW OFTEN SHOULD PERCUTANEOUS GASTROSTOMY FEEDING TUBES BE REPLACED? A SINGLE-INSTITUTE RETROSPECTIVE STUDY. BMJ OPEN GASTRO 2022;9:E000881. DOI:10.1136/BMJGAST-2022-000881 INVESTIGATION EVALUATION: A PRODUCT EVALUATION WAS NOT PERFORMED IN RESPONSE TO THIS REPORT BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT PROVIDED TO COOK FOR EVALUATION. THE REPORT COULD NOT BE CONFIRMED. A REVIEW OF THE DEVICE HISTORY RECORD COULD NOT BE CONDUCTED BECAUSE THE LOT NUMBER WAS NOT PROVIDED. INVESTIGATION CONCLUSION: WE COULD NOT CONDUCT A COMPLETE INVESTIGATION BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT RETURNED FOR EVALUATION. A DEFINITIVE CAUSE FOR THE REPORTED OBSERVATION COULD NOT BE DETERMINED. PRIOR TO DISTRIBUTION, ALL PERCUTANEUOUS ENDOSCOPIC GASTROSTOMY SETS ARE SUBJECTED TO A VISUAL INSPECTION AND FUNCTIONAL TESTING TO ENSURE DEVICE INTEGRITY. CORRECTIVE ACTION: A REVIEW OF THE COMPLAINT HISTORY WAS CONDUCTED. THE LIKELIHOOD OF OCCURRENCE IS CONSIDERED RARE. CORRECTIVE ACTION IS NOT WARRANTED AT THIS TIME BASED ON THE QUALITY ENGINEERING RISK ASSESSMENT. QUALITY ASSURANCE WILL CONTINUE TO MONITOR FOR COMPLAINT TRENDS AND REASSESS THE RISK ASSESSMENT RESULTS AS POST MARKET FEEDBACK CONTINUES TO BECOME AVAILABLE.

Description of Event or Problem · 0

THE FOLLOWING WAS PUBLISHED IN A CLINICAL LITERATURE INVOLVING COOK FLOW 20 PERCUTANEOUS ENDOSCOPIC GASTROSTOMY SET - PULL. RELEVANT EXCERPTS ARE AS FOLLOWS: ALTHOUGH THIS MINIMALLY INVASIVE PROCEDURE IS QUITE SAFE AND INSTRUCTIONS FOR TUBE CARE ARE WELL-KNOWN, THE RISKS OF MINOR OR MAJOR COMPLICATIONS (SUCH AS WOUND INFECTION, OCCLUSION, PERISTOMAL LEAKAGE, TUBE DISLODGEMENT, STOMAL HYPERGRANULATION, AND BURIED BUMPER SYNDROME) INCREASE AS LONG AS TUBE FEEDING PERSISTS. BECAUSE OF SUCH COMPLICATIONS, THE PG TUBE SHOULD BE EXCHANGED PERIODICALLY; THE STUDY POPULATION INCLUDED ALL PATIENTS WHO UNDERWENT ENDOSCOPIC OR RADIOLOGIC PG TUBE PLACEMENT (INITIAL OR EXCHANGE) FOR LONG-TERM ENTERAL FEEDING AT SHEIKH KHALIFA SPECIALTY HOSPITAL IN RAS AL KHAIMAH, UNITED ARAB EMIRATES, BETWEEN 2016 AND 2020. PG TUBE INSERTION WAS PERFORMED FOR PATIENTS DEEMED BY PHYSICIANS TO REQUIRE ENTERAL TUBE FEEDING FOR MORE THAN 30 DAYS IN ORDER TO AVOID ANY LONG-TERM COMPLICATIONS FROM NASOGASTRIC TUBE FEEDING. REPLACEMENT TUBES WERE INSERTED THROUGH THE STOMAL TRACT AFTER THE PREVIOUS TUBES WERE REMOVED; FOR THE INITIAL ENDOSCOPIC AND RADIOLOGIC PG TUBE INSERTION, WE USED A 20 FRENCH (FR) FLOW-20-PULL-I-S(COOK MEDICAL EUROPE) PG SET. COMPLAINTS WERE: TUBE DAMAGE: N (%) 8 (3.85) SUBJECT OF THIS REPORT. ALL PATIENTS WHO UNDERWENT LONG-TERM ENTERAL FEEDING TUBE PLACEMENT AND REPLACEMENT PROCEDURES BY GASTROINTESTINAL ENDOSCOPISTS AND INTERVENTION RADIOLOGISTS AT SHEIKH KHALIFA SPECIALTY HOSPITAL BETWEEN 2015 AND 2020 WERE EXTRACTED FROM THE HOSPITAL¿S MEDICAL RECORDS SYSTEM. AMONG 721 TUBE PLACEMENTS, 599 WERE PG-RELATED AND REMNANT PROCEDURES, 62 INVOLVED NASOENTERIC FEEDING TUBE INSERTION, 4 WERE FOR FEEDING TUBES INSERTED VIA SURGICAL GASTROSTOMY OR JEJUNOSTOMY, AND 56 WERE FOR TUBE CHECK ONLY. IT WAS NOT REPORTED IF A SECTION OF THE DEVICE REMAINED INSIDE THE PATIENT¿S BODY. IT WAS NOT PUBLISHED IF ANY ADDITIONAL PROCEDURES WERE REQUIRED DUE TO THIS OCCURRENCE. IT WAS NOT PUBLISHED IF THE PATIENT EXPERIENCED ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
356606 FLOW 20 PERCUTANEOUS ENDOSCOPIC GASTROSTOMY SET - PULL KNT, TUBE, GASTROINTESTINAL (AND ACCESSORIES) KNT WILSON-COOK MEDICAL INC UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 Unknown ENDOSCOPE - UNKNOWN MAKE AND MODEL