ARCHITECT I2000SR ANALYZER
Report
- Report Number
- 1628664-2010-00011
- Event Type
- Malfunction
- Date Received
- January 19, 2010
- Date of Event
- January 4, 2010
- Report Date
- January 7, 2010
- Manufacturer
- ABBOTT MANUFACTURING, INC.
- Product Code
- MMI
- PMA / PMN Number
- K983212
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
(B)(4). ARCH STAT TROPONIN-I LN:2K41 LOT: 34609UN09 EXPIRES: 31 AUGUST 2010. TO INVESTIGATE THE CURRENT CUSTOMER ISSUE, A REVIEW WAS PERFORMED OF THE COMPLAINT TEXT, INSTRUMENT HISTORY, AND THE ARCHITECT SYSTEM LABELING. ERRONEOUS RESULTS GENERATED FOR ONE OF THE SAMPLES IN QUESTION MAY HAVE BEEN CAUSED BY A HIGH FIBRIN CONTENT OBSERVED IN THE SAMPLE. THE CUSTOMER WAS NOT FOLLOWING THE ARCHITECT OPERATIONS MANUAL INSTRUCTIONS ON USING 0.5% HYPOCHLORITE SOLUTION FOR THE DAILY MAINTENANCE PROCEDURE. THE CUSTOMER WAS USING A 1% SOLUTION INSTEAD. A REVIEW OF THE SERVICE HISTORY FOR THE ARCHITECT I2000SR ANALYZER, (B)(4), ALONG WITH THE COMPLAINT DATABASES IDENTIFIED NO ADVERSE TRENDS IN CONJUNCTION WITH THE COMPLAINT ISSUE CURRENTLY UNDER EVALUATION. THE ARCHITECT SYSTEM OPERATIONS MANUAL (201837-105) AND THE STAT TROPONIN-I (TNI II) REAGENT PACKAGE INSERT (840638/R7) BOTH CONTAIN INFORMATION TO ADDRESS THE CUSTOMER'S ISSUE. BASED ON THE AVAILABLE INFORMATION FOR THIS CURRENT INVESTIGATION, A PRODUCT MALFUNCTION WAS NOT IDENTIFIED. THIS IS A FINAL REPORT.
(B)(4). ARCH STAT TROPONIN-I: LN:2K41, LOT: 34609UN09, EXPIRES: 31 AUGUST 2010. THIS IS AN INITIAL REPORT. AN INVESTIGATION IS IN PROCESS. A FINAL REPORT WILL BE SUBMITTED WHEN THE INVESTIGATION IS COMPLETE.
THE CUSTOMER STATES THAT ONE PATIENT GENERATED THE FOLLOWING ARCHITECT STAT TROPONIN-I ASSAY RESULTS: (B)(6) 2010: 13:40, 0.05 NMOL/L; (B)(6) 2010: 18:00, 0.06 NMOL/L; (B)(6) 2010: 00.05, 0.01 NMOL/L (ISTAT METHODOLOGY); (B)(6) 2010: 0.13 NMOL/L; ISTAT RESULTS:0.01 / 0.00 NMOL/L. THE (B)(4) 2010 SAMPLE WAS RECENTRIFUGED AND RETESTED AND GENERATED AN ARCHITECT STAT TROPONIN-I ASSAY RESULT OF 0.05 NMOL/L. THE CUSTOMER USES A CUT-OFF VALUE OF 0.03 NG/ML. CONTROLS HAVE REMAINED WITHIN SPECIFICATIONS. THERE IS NO IMPACT TO PATIENT MANAGEMENT REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | ARCHITECT I2000SR ANALYZER | AUTOMATED IMMUNOASSAY ANALYZER | MMI | ABBOTT MANUFACTURING, INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | ARCH STAT TROPONIN-I: LN:2K41-38| ARCH STAT TROPONIN-I: LN:2K41-38 |