BD SMARTSITE¿ NEEDLE-FREE CONNECTOR, PRIMING VOLUME 0.11 ML
Report
- Report Number
- 9616066-2022-01697
- Event Type
- Malfunction
- Date Received
- November 9, 2022
- Date of Event
- September 28, 2022
- Report Date
- November 1, 2022
- Manufacturer
- SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
- Product Code
- FPA
- PMA / PMN Number
- K061285
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
2000E CHINA 510K: THIS IS AN INTERNATIONAL CODE - THE MODEL#/CATALOG# IDENTIFIED IS A CAREFUSION PRODUCT WHICH IS SAME OR SIMILAR TO A DEVICE THAT IS APPROVED FOR SALE DOMESTICALLY. THE DOMESTIC SIMILAR LIST NUMBER IS 2000E. THE 510K NUMBER PROVIDED IS FOR THE DOMESTIC SIMILAR PRODUCT: K061285. INVESTIGATION SUMMARY: A 2000E CHINA PRODUCT WAS NOT AVAILABLE FOR INVESTIGATION; HOWEVER, THE CUSTOMER INDICATES THE COMPLAINT SAMPLE IS FROM LOT 22025973. THE FEEDBACK PROVIDED BY THE CUSTOMER INDICATES A COMPLETE OCCLUSION WAS DETECTED AT THE SMARTSITE COMPONENT DURING PRIMING. THE CUSTOMER ALSO INDICATED THE SMARTSITE DEVICE WAS CONNECTED TO AN UNKNOWN PICC LINE. THE DETAILS OF THIS FEEDBACK WERE FORWARDED TO THE MANUFACTURING SITE FOR INVESTIGATION. A REVIEW OF THE PRODUCTION RECORDS FOR LOT 22025973 DID NOT IDENTIFY ANY IN-PROCESS TESTING FAILURES OR QUALITY DEVIATIONS WHICH MAY HAVE RESULTED IN A REPORT OF THIS NATURE. THE ROOT CAUSE OF THE CUSTOMER¿S EXPERIENCE COULD NOT BE DETERMINED AS THE SAMPLE WAS NOT AVAILABLE FOR INVESTIGATION. IN THIS INSTANCE, WITHOUT A SAMPLE IT IS NOT POSSIBLE TO DETERMINE WHETHER A MANUFACTURING DEFECT COULD HAVE CAUSED OR CONTRIBUTED TO THE CUSTOMER¿S EXPERIENCE. PREVIOUS COMPLAINTS FOR OCCLUSIONS HAVE BEEN RELATED TO FEATURES ON THE SURFACE OF THE MALE LUER OF THE CONNECTING PRODUCTS. THESE FEATURES INCLUDE FLASH OR A RAISED EDGE TO THE TIP OF THE MALE LUER WHICH HAVE PREVIOUSLY BEEN SHOWN TO INTERMITTENTLY LEAD TO RESTRICTED FLOW DUE TO THEM PINCHING THE BLUE PISTON OF THE SMARTSITE® AND NOT ALLOWING IT TO OPEN. THIS CAN SOMETIMES BE RESOLVED BY DISCONNECTING AND REATTACHING THE SAME LUER CONNECTION WHICH MAY REPOSITION THE LUER AGAINST THE PISTON AND IMPROVE THE FLOW, OR ALTERNATIVELY BY CHANGING THE CONNECTING MALE LUER. A REVIEW OF THE CUSTOMER FEEDBACK DATABASE INDICATES THAT THIS IS A RARE OCCURRENCE WITH A SMALL NUMBER OF SIMILAR REPORTS AGAINST THE SMARTSITE COMPONENT IN THE PAST 12 MONTHS.
IT WAS REPORTED WHILE USING BD SMARTSITE¿ NEEDLE-FREE CONNECTOR, PRIMING VOLUME 0.11 ML THE NEEDLE WAS CLOGGED. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM CHINESE TO ENGLISH: ON (B)(6) 2022, WHEN PERFORMING PICC MAINTENANCE FOR THE PATIENT, THE FLUSHING SOLUTION COULD NOT BE INJECTED INTO THE TUBE. THE MAINTENANCE WAS PERFORMED AGAIN AFTER REPLACING THE NEEDLE-FREE CLOSED INFUSION CONNECTOR, AND THE OPERATION WAS NORMAL.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2950056 | BD SMARTSITE¿ NEEDLE-FREE CONNECTOR, PRIMING VOLUME 0.11 ML | INTRAVASCULAR ADMINISTRATION SET | FPA | SISTEMAS MEDICOS ALARIS, S.A. DE C.V. | 22025973 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |