COLON DECOMPRESSION SET
Report
- Report Number
- 3001845648-2022-00755
- Event Type
- Malfunction
- Date Received
- November 8, 2022
- Report Date
- November 16, 2022
- Manufacturer
- COOK IRELAND LTD
- Product Code
- FEG
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MN, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
PMA/510(K) # K171619. DEVICE EVALUATION. THE CDSG-14-175 DEVICE OF UNKNOWN LOT NUMBER INVOLVED IN THIS COMPLAINT WAS NOT AVAILABLE FOR EVALUATION. WITH THE INFORMATION PROVIDED, A DOCUMENT-BASED INVESTIGATION WAS CONDUCTED. DOCUMENT REVIEW: MANUFACTURING RECORDS REVIEW COULD NOT BE COMPLETED AS THE LOT NUMBER IS UNKNOWN. HOWEVER, PRIOR TO DISTRIBUTION ALL CDSG-14-175 DEVICES ARE SUBJECT TO VISUAL A VISUAL INSPECTION AND FUNCTIONAL CHECKS TO ENSURE DEVICE INTEGRITY. THESE INSPECTIONS AND FUNCTIONAL CHECKS ARE OUTLINED IN INTERNAL PROCEDURES IN PLACE AT CIRL . REVIEW OF HISTORICAL DATA: HISTORICAL DATA WAS NOT REVIEWED AS THE LOT NUMBER IS UNKNOWN. THE INSTRUCTIONS FOR USE, IFU0102, STATES THE FOLLOWING IN RELATION TO THE INTENDED USE OF THE DEVICE: ¿THE DEVICE IS INTENDED FOR TREATMENT OF ACUTE NON-TOXIC MEGACOLON, PSEUDO-OBSTRUCTION (OGILVIE'S SYNDROME) AND COLONIC STRICTURES." THERE IS EVIDENCE TO SUGGEST THAT THE CUSTOMER DID NOT FOLLOW THE INSTRUCTIONS FOR USE. ROOT CAUSE REVIEW: A DEFINITIVE ROOT CAUSE OF OFF LABEL USE WAS DETERMINED. IT IS KNOWN THAT THE DEVICE WAS USED IN THE VOLVULUS. THE INSTRUCTIONS FOR USE STATE THAT THE INTENDED USE FOR THE DEVICE IS FOR THE TREATMENT OF ACUTE NON-TOXIC MEGACOLON, PSEUDO-OBSTRUCTION (OGILVIE'S SYNDROME) AND COLONIC STRICTURES. THE USE OF THE CDSG DEVICE IN THE VOLVULUS IS OFF LABEL USE. SUMMARY: COMPLAINT IS CONFIRMED BASED ON CUSTOMER AND/OR REP TESTIMONY. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE. COMPLAINTS OF THIS NATURE WILL CONTINUE TO BE MONITORED FOR POTENTIAL EMERGING TRENDS.
PMA/510(K) # K171619. INVESTIGATION IS STILL PENDING, A FOLLOW UP MDR WILL BE SUBMITTED TO INCLUDE THE INVESTIGATION CONCLUSIONS.
A SUPPLEMENTAL REPORT IS BEING SUBMITTED DUE TO COMPLETION OF THE INVESTIGATION.
AS REPORTED TO CUSTOMER RELATIONS VIA CRI FORM "CDSG-14-175 MIGRATED 24 HOURS AFTER THE INITIAL PLACEMENT PROCEDURE. THE EVENT WAS REPORTED AS NOT RELATED TO THE COLON DECOMPRESSION SET AND NOT RELATED TO THE STUDY PROCEDURE." THERE WAS NO TREATMENT OF THE EVENT. THE DEVICE WAS REMOVED AT 48 HOURS AFTER INITIAL PLACEMENT PROCEDURE AND WAS NOT REPLACED. TREATMENT WITH THE COLON DECOMPRESSION SET WAS CONSIDERED NOT SUCCESSFUL DUE TO CLINICAL SYMPTOMS. NO OTHER ADVERSE EVENTS WERE REPORTED PRIOR TO THE PATIENT BEING EXITED FROM THE STUDY. FINAL PMCF REPORT RECEIVED ON (B)(6) 2022. IT WAS CONFIRMED BY MEDICAL AFFAIRS THAT THE USE OF CDSG DEVICE IN THE VOLVULUS IS OFF LABEL USE. THERE WAS NO TREATMENT OF THE EVENT. THE DEVICE WAS REMOVED AT 48 HOURS AFTER INITIAL PLACEMENT PROCEDURE AND WAS NOT REPLACED. TREATMENT WITH THE COLON DECOMPRESSION SET WAS CONSIDERED NOT SUCCESSFUL DUE TO CLINICAL SYMPTOMS. NO OTHER ADVERSE EVENTS WERE REPORTED PRIOR TO THE PATIENT BEING EXITED FROM THE STUDY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2334857 | COLON DECOMPRESSION SET | FEG TUBE, DOUBLE LUMEN FOR INTESTINAL DECOMPRESSION AND/OR INTUBATION | FEG | COOK IRELAND LTD | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |