FDA Adverse Event Malfunction Summary report: N

HAMILTON MEDICAL AG

MDR report key: 15721041 · Received November 3, 2022

Report

Report Number
3001421318-2022-00043
Event Type
Malfunction
Date Received
November 3, 2022
Date of Event
September 29, 2022
Report Date
March 27, 2023
Manufacturer
HAMILTON MEDICAL AG
Product Code
CBK
UDI-DI
07630002808590
PMA / PMN Number
K201658
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

CONCLUSION OF CER (B)(4) : HAMILTON MEDICAL AG HAS NOT YET INVESTIGATED THE CASE BASED. HAMILTON MEDICAL IS WAITING FOR THE DEVICE TO INVESTIGATE THE CLAIMED ISSUE " DEVICE WENT IN STANDBY WITHOUT OPERATOR'S INTERACTION" IT WAS CLAIMED AN AMBIENT MODE (VENTILATION STOP), BUT IT IS NOT YET CONFIRMED. NO PATIENT WAS HARMED. THE INVESTIGATION SHOWED THAT A HARDWARE RELATED ISSUE LED TO THE HAMILTON-C6 GOING INTO "AMBIENT STATE". DURING "AMBIENT STATE" THE INSPIRATORY CHANNEL AND EXPIRATORYVALVES ARE OPENED, LETTING THE PATIENT BREATHE ROOM AIR UNASSISTED. CONCLUSION: INVESTIGATION - PENDING. CAUSE: INVESTIGATION - PENDING.

Additional Manufacturer Narrative · 0

CONCLUSION OF CER (B)(4) : FROM THE INFORMATION RECEIVED AND THE ANALYSIS PERFORMED REGARDING THIS CASE, THE ROOT CAUSE OF THIS EVENT WAS DUE TO A USE ERROR. THE HAMILTON-C6 WORKED AS INTENDED. THE LOG FILE ANALYSIS INDICATE THAT THE VENTILATOR WAS PUT MANUALLY INTO STANDBY MODE. TWO INDEPENDENT STEPS ARE REQUIRED TO GET INTO STANDBY MODE: 1. PRESS THE HARDKEY ON THE INTERACTION PANEL, AND 2. CONFIRM WITH THE TOUCHSCREEN OR 1. PRESS THE HARDKEY ON THE VENTILATOR UNIT, AND 2. CONFIRM WITH THE TOUCHSCREEN. CONCLUSION: THE VENTILATOR WORKED AS INTENDED AND THE USER PUT THE VENTILATIOR INTO STANDBY MODE MANUALLY.

Description of Event or Problem · 0

THE FOLLOWING WAS REPORTED TO HAMILTON MEDICAL AG: DESCRIPTION FROM HOSPITAL: AT (B)(6) HOSPITAL THE DEVICE HAS ENTERED AMBIENT STATE WHILE VENTILATING A PATIENT. FIRST INFORMATION HAS IT THAT THE PATIENT WAS NOT INJURED. ORIGINAL CUSTOMER COMPLAINT: THE DEVICE SWITCHED TO AMBIENT MODE DURING VENTILATION.SOME TECHNICAL FAULTS WERE LOGGED.

Description of Event or Problem · 0

THE FOLLOWING WAS REPORTED TO HAMILTON MEDICAL AG: ORIGINAL CUSTOMER COMPLAINT: IL CLIENTE DICE CHE IERI ALLE 14.17 IL VENTILATORE È ANDATO IN STAND BY DA SOLO. TRANSLATED WITH WWW.DEEPL.COM: THE CLIENT SAYS THAT YESTERDAY AT 2:17 P.M. THE FAN WENT INTO STANDBY BY ITSELF. *NOTE THE COMPLAINT DESCRIPTION OF THE INTIAL MDR WAS A COPY AND PASTE ERROR AND WAS MISTAKELY OVERTOOK FROM A TEMPLATE. AS WELL THE SERIAL NUMBER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2788963 HAMILTON MEDICAL AG HAMILTON-C6 VENTILATOR CBK HAMILTON MEDICAL AG 160021 07630002808590

Patients

Seq Age Sex Outcome Treatment
1 Unknown