FDA Adverse Event Injury Summary report: N

UNK_E-Z CLEAN NON-STICK ELECTROSURGICAL ELECTRODES

MDR report key: 15708493 · Received November 1, 2022

Report

Report Number
1721194-2022-00105
Event Type
Injury
Date Received
November 1, 2022
Date of Event
January 1, 2022
Report Date
November 1, 2022
Manufacturer
MEGADYNE MEDICAL PRODUCTS, INC.
Product Code
GEI
PMA / PMN Number
K081791
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT: DOES THE AUTHOR/SURGEON BELIEVE THAT THE ETHICON DEVICE CAUSED OR CONTRIBUTED TO THE PATIENT COMPLICATIONS MENTIONED IN THE ARTICLE? IF YES, PLEASE EXPLAIN. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 0

TITLE: THE CLEFT LIFT PROCEDURE FOR PILONIDAL DISEASE RENAMED AS A ROTATION AND ADVANCEMENT FLAP PROCEDURE (RAF): INSIGHTS AND TECHNICAL TIPS FOR A SUCCESSFUL OUTCOME. AUTHOR: JEFFREY A. STERNBERG, MD. CITATION CITE : SEMINARS IN COLON AND RECTAL SURGERY 000 (2022) 100913. HTTPS://DOI.ORG/10.1016/J.SCRS.2022.100913. THIS TECHNICAL PAPER DECONSTRUCTS THE CONFUSING TERMINOLOGY, SUGGESTS SIMPLE STEPS FOR SUCCESS, AND PROPOSES A MORE DESCRIPTIVE NAME FOR THE ASYMMETRIC FLAP PROCEDURE WHICH HAS THE LOWEST REPORTED RECURRENCES FOR ALL SURGICAL OPTIONS FOR PILONIDAL DISEASE. THE AUTHOR HAS SUCCESSFULLY PERFORMED THE CLEFT LIFT PROCEDURE FOR PILONIDAL DISEASE SINCE 2000. IN THE LAST CONSECUTIVE 757 PATIENTS TREATED OVER 12 YEARS. USING A KNIFE OR ELECTROCAUTERY ON A CLEAN PURE CUTTING MODE (ACE BY MEGADYN). REPORTED COMPLICATION INCLUDED MINIMAL POSTOPERATIVE DISCOMFORT AND ACTUALLY EXPERIENCE NUMBNESS ON THE FLAP SIDE OF THE INCISION FOR 6 TO 8 WEEKS. 6 PATIENTS REQUIRED A SECOND OPERATION DUE TO RECURRENCE. IN CONCLUSION THE PILONIDAL RAF PROCEDURE IS HIGHLY SUCCESSFUL IN TREATING PILONIDAL SINUS DISEASE WITH A VERY LOW NEED FOR ADDITIONAL SURGERY EVEN IN COMPLEX RECURRENT DISEASE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
482074 UNK_E-Z CLEAN NON-STICK ELECTROSURGICAL ELECTRODES E-Z CLEAN BAYONET NEEDLE 6 INCH GEI MEGADYNE MEDICAL PRODUCTS, INC.

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention