FDA Adverse Event Malfunction Summary report: N

VCL+ VIO 27IN 1 S/A CT-1

MDR report key: 15674691 · Received October 26, 2022

Report

Report Number
2210968-2022-08790
Event Type
Malfunction
Date Received
October 26, 2022
Date of Event
September 30, 2022
Report Date
February 6, 2023
Manufacturer
ETHICON INC.
Product Code
GAM
UDI-DI
10705031052512
PMA / PMN Number
K132580
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). ADDITIONAL INFORMATION HAS BEEN REQUESTED AND RECEIVED. ATTEMPTS TO OBTAIN THE DEVICE HAVE BEEN MADE, HOWEVER NOT RECEIVED TO DATE. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. WHAT IS THE LOT NUMBER?=>NO FURTHER INFORMATION IS AVAILABLE. * DEVICE RETURN FOLLOW UP.=>WE REGULARLY CONTACT WITH SALES REP ABOUT THE DEVICE RETURNING. NO FURTHER INFORMATION WILL BE PROVIDED." TRADE NAME - IRGACARE® ACTIVE INGREDIENT(S) ¿ TRICLOSAN, DOSAGE FORM ¿ SUTURE/SOLID/PARENTERAL, STRENGTH ¿ = 275 G/M VICRYL CE, THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

(B)(4). THIS IS A COMBINATION PRODUCT, AND THE EVENT HAS BEEN REVIEWED FOR BOTH THE SUTURE AND THE TRICLOSAN. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. H3 ANALYSIS SUMMARY: THE PRODUCT WAS RETURNED TO ETHICON FOR EVALUATION. VISUAL INSPECTION EVALUATION WAS CONDUCTED ON THE RETURNED DEVICE. VISUAL ANALYSIS OF THE RETURNED SAMPLE DETERMINED THAT IT WAS RECEIVED ONE EMPTY WINDING FORMER, A PAPER LID AND A NEEDLE-SUTURE THAT PERTAINS TO PRODUCT CODE VCP341. IN ORDER TO EVALUATE THE CONDITIONS OF THE RETURNED SAMPLE, IT WAS OBSERVED THE NEEDLE WAS BROKEN AT THE TIP AREA. IN ADDITION, MARKS THAT APPEAR TO BE OF A SURGICAL INSTRUMENT WERE FOUND ON THE NEEDLE. THIS SAMPLE WILL BE SHIPPED TO HSA FOR FURTHER ANALYSIS DUE TO THE NEEDLE BREAKAGE. THE MANUFACTURING RECORDS COULDN'T BE REVIEWED AS THE BATCH/LOT NUMBER IS UNKNOWN. NO CONCLUSION COULD BE REACHED DUE TO THE SAMPLE NEEDS ADDITIONAL EVALUATION. AS PART OF THE ETHICON QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). DATE SENT TO THE FDA: 2/6/2023. THIS IS A COMBINATION PRODUCT, AND THE EVENT HAS BEEN REVIEWED FOR BOTH THE SUTURE AND THE TRICLOSAN. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ADDITIONAL INFORMATION: D9, H3, H6. H3 INVESTIGATIONAL SUMMARY: THE PRODUCT RECEIVED FOR ANALYSIS WAS IDENTIFIED AS PRODUCT CODE VCP341H. VISUAL INSPECTION AND METALLURGICAL ANALYSIS WERE PERFORMED ON THE RETURNED PRODUCT. A FRACTURE WAS OBSERVED AT THE TIP OF THE NEEDLE. ONE SIDE OF THE NEEDLE WAS RECEIVED, THE MATING FRACTURE SURFACE WAS NOT PROVIDED FOR THIS EVALUATION. THE NEEDLE WAS NOTED WITH MARKS THAT APPEARS TO BE BY SURGICAL INSTRUMENT. A SCANNING ELECTRON MICROSCOPE WAS USED TO EXAMINE THE FRACTURE SURFACES AND SURROUNDING AREA OF THE NEEDLE. THE FRACTURE SURFACES WERE EXAMINED IN MULTIPLE LOCATIONS TO DETERMINE THE FRACTURE MODE. THE EVALUATION OF THE SAMPLE REVEALED THE FRACTURE WAS COMPOSED OF MICROVOID COALESCENCE, WHICH IS EVIDENCE OF A DUCTILE FRACTURE MODE. MECHANICAL DAMAGE OBSERVED COINCIDENTAL TO THE FRACTURE PROVIDES ADDITIONAL EVIDENCE THAT THE FAILURE WAS INDUCED BY MECHANICAL DEFORMATION LEADING TO DUCTILE OVERLOAD. THIS WAS A DUCTILE FRACTURE. THE EVIDENCE OF THIS EXAMINATION INDICATES THAT THE BREAKAGE OCCURRED AT THE TIP OF THE NEEDLE DURING USE DUE TO TENSILE OVERLOAD. THERE IS NO EVIDENCE OF ANY MATERIAL FLAW OR DEFECT THAT WOULD CAUSE PREMATURE FAILURE. ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS IS CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF POST-MARKET SURVEILLANCE.

Description of Event or Problem · 0

IT WAS REPORTED A PATIENT UNDERWENT AN UNKNOWN OBSTETRICS AND GYNECOLOGY PROCEDURE ON (B)(6) 2022 AND A SUTURE WAS USED. THE NEEDLE BROKE DURING USE. AFTER THE NEEDLE WAS BROKEN, THE BROKEN NEEDLE DID NOT FALL INTO THE PATIENT¿S BODY. SUTURE METHOD WAS CONTINUOUS SUTURE. FURTHER DETAILS ARE NOT PROVIDED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2481118 VCL+ VIO 27IN 1 S/A CT-1 SUTURE, ABSORBABLE, SYNTHETIC GAM ETHICON INC. VCP341H 10705031052512

Patients

Seq Age Sex Outcome Treatment
1 Unknown