FDA Adverse Event Death Summary report: N

MITRACLIP® SYSTEM CLIP DELIVERY SYSTEM

MDR report key: 15473043 · Received September 23, 2022

Report

Report Number
2135147-2022-01324
Event Type
Death
Date Received
September 23, 2022
Date of Event
November 1, 2018
Report Date
September 22, 2022
Manufacturer
ABBOTT MEDICAL
Product Code
NKM
PMA / PMN Number
P100009
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
AU
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE WAS NOT RETURNED FOR ANALYSIS AND A REVIEW OF THE LOT HISTORY RECORD AND SIMILAR COMPLAINT REVIEW COULD NOT BE PERFORMED AS THE PART AND LOT NUMBER REGARDING THE COMPLAINT DEVICE WAS NOT PROVIDED. THE INVESTIGATION WAS UNABLE TO DETERMINE A CAUSE FOR THE REPORTED DEATH. DEATH IS LISTED IN THE INSTRUCTIONS FOR USE AS KNOWN POSSIBLE COMPLICATIONS ASSOCIATED WITH MITRACLIP PROCEDURES. THE REPORTED HOSPITALIZATION WAS A RESULT OF CASE-SPECIFIC CIRCUMSTANCE. THERE IS NO INDICATION OF A PRODUCT ISSUE WITH RESPECT TO MANUFACTURE, DESIGN, OR LABELING. DATE OF EVENT AND IMPLANT DATE: DATES ESTIMATED. D4: THE UDI NUMBER IS NOT KNOWN AS THE PART AND LOT NUMBERS WERE NOT PROVIDED. THE ADDITIONAL ADVERSE EVENTS REPORTED IN THE ARTICLE ARE CAPTURED UNDER SEPARATE MEDWATCH REPORTS. ATTACHMENT: ARTICLE TITLED "UNVEILING CARDIAC AMYLOIDOSIS ITS CHARACTERISTICS, AND OUTCOMES AMONG PATIENTS WITH MR UNDERGOING TRANSCATHETER EDGE-TO-EDGE MV REPAIR".NA

Description of Event or Problem · 0

THIS IS FILED FOR PATIENT DEATH. THIS PROSPECTIVE RESEARCH ARTICLE EVALUATED THE PREVALENCE, PREDICTORS, AND OUTCOMES OF CARDIAC AMYLOIDOSIS IN CONSECUTIVE PATIENTS REFERRED FOR TRANSCATHETER EDGE-TO-EDGE (TEER) THERAPY. IT WAS REPORTED THAT 120 PATIENTS UNDERWENT TEER USING A MITRACLIP OR PASCAL DEVICE BETWEEN (B)(6) 2018 TO (B)(6) 2021. COMPLICATIONS INCLUDED CARDIOVASCULAR DEATH, ALL CAUSE DEATH AND HYPERTENSIVE HEART FAILURE (HHF) REQUIRING HOSPITALIZATION. IN CONCLUSION, DUAL PATHOLOGY OF MITRAL REGURGITATION (MR) AND CARDIAC AMYLOIDOSIS IS COMMON IN ELDERLY PATIENTS WITH MR UNDERGOING TEER AND HAS WORSE POSTINTERVENTIONAL OUTCOMES COMPARED WITH LONE MR. DETAILS ARE LISTED IN THE ATTACHED ARTICLE TITLED, UNVEILING CARDIAC AMYLOIDOSIS ITS CHARACTERISTICS, AND OUTCOMES AMONG PATIENTS WITH MR UNDERGOING TRANSCATHETER EDGE-TO-EDGE MV REPAIR".

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2929345 MITRACLIP® SYSTEM CLIP DELIVERY SYSTEM VALVE REPAIR NKM ABBOTT MEDICAL

Patients

Seq Age Sex Outcome Treatment
1 77 YR Male Death