FDA Adverse Event Malfunction Summary report: N

HIP BITER STRAIGHT EXPRESSEW III SUTURE PASSER W/O HOOK

MDR report key: 15450458 · Received September 19, 2022

Report

Report Number
1221934-2022-02863
Event Type
Malfunction
Date Received
September 19, 2022
Date of Event
July 25, 2022
Manufacturer
DEPUY MITEK LLC US
Product Code
LXH
UDI-DI
10886705020218
PMA / PMN Number
EXEMPT
Removal / Correction Number
N/A
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS REPORT IS BEING SUBMITTED IN PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY DEPUY MITEK OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY MITEK, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. UDI: (B)(4). INITIAL REPORTER IS A J&J SALES REPRESENTATIVE. THE EXPIRATION DATE AND DEVICE MANUFACTURE DATE ARE CURRENTLY UNAVAILABLE. INVESTIGATION SUMMARY: THE COMPLAINT DEVICE WAS RECEIVED AND EVALUATED. UPON VISUAL INSPECTION, IT COULD BE OBSERVED THAT THE DEVICE HAS SOME MARKS OF USE AS USUAL ON THESE TYPE OF REUSABLE DEVICES. THE DEVICE DOES NOT SHOW ANY STRUCTURAL ANOMALIES. THE JAW IS NOT BROKEN, HOWEVER IT IS LOOSE. WHEN THE TRIGGER WAS FULLY DEPRESSED, THE JAW CANNOT BE CLOSED COMPLETELY. DUE TO THE CONDITION OF THE JAW, THE FUNCTIONAL TEST CANNOT BE PERFORMED. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE 38202-160707-01 NUMBER, AND NO NON-CONFORMANCES WERE IDENTIFIED. AS PART OF DEPUY SYNTHES MITEK QUALITY PROCESS ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. ACCORDING WITH THE VISUAL INSPECTION RESULT, THIS COMPLAINT CAN BE CONFIRMED. THE POSSIBLE ROOT CAUSE FOR THE LOOSE JAW CONDITION CAN BE ATTRIBUTED TO PROCEDURAL VARIABLES, SUCH HANDLING OF THE DEVICE OR PRODUCT INTERACTION DURING PROCEDURE, A BIGGER PORTION OF TISSUE MAY HAVE BEEN GRABBED AND FORCED THE JAW TO CLOSE, ALSO, SINCE THIS DEVICE IS REUSABLE, THE CONTINUOUS USE AND STERILIZATION PROCESS CAN CAUSE METAL FATIGUE LEADING TO A NON-CLOSING JAW, HOWEVER, THIS CANNOT BE CONCLUSIVELY DETERMINED. AT THIS POINT IN TIME, NO CORRECTIVE ACTION IS REQUIRED, AND NO FURTHER ACTION IS WARRANTED. HOWEVER, DEPUY SYNTHES MITEK WILL CONTINUE TO MONITOR ADDITIONAL COMPLAINT INFORMATION FOR POTENTIAL SAFETY SIGNALS THROUGH COMPLAINT TRENDING AS PART OF POST MARKET SURVEILLANCE.

Description of Event or Problem · 0

THIS IS REPORT 1 OF 2 FOR (B)(4). IT WAS REPORTED BY THE SALES REP THAT DURING A ROTATOR CUFF REPAIR PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE EXPRESSEW III SUTURE PASSER W/O HOOK DEVICE WAS NO LONGER FUNCTIONING PROPERTY AS IT HAS BROKEN JAWS. DURING IN-HOUSE ENGINEERING EVALUATION, IT WAS DETERMINED THAT THE JAW WAS NOT BROKEN BUT IT WAS LOOSE. ACCORDING TO THE EVALUATION, WHEN THE TRIGGER WAS FULLY DEPRESSED, THE JAW COULD NOT BE CLOSED COMPLETELY. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2550721 HIP BITER STRAIGHT EXPRESSEW III SUTURE PASSER W/O HOOK SUTURE/NEEDLE PASSER, REUSABLE LXH DEPUY MITEK LLC US 214140 38202-160707-01 10886705020218

Patients

Seq Age Sex Outcome Treatment
1 Unknown