FDA Adverse Event Malfunction Summary report: N

BD PHASEAL ¿ L CONNECTOR C90J

MDR report key: 15407247 · Received September 12, 2022

Report

Report Number
3003152976-2022-00413
Event Type
Malfunction
Date Received
September 12, 2022
Date of Event
August 17, 2022
Report Date
October 20, 2022
Manufacturer
BECTON DICKINSON, S.A.
Product Code
ONB
PMA / PMN Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THERE WERE MULTIPLE POTENTIAL LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH ADDITIONAL LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 2111212, MEDICAL DEVICE EXPIRATION DATE: 31OCT2025, DEVICE MANUFACTURE DATE: 19NOV2021; MEDICAL DEVICE LOT #: 2111214, MEDICAL DEVICE EXPIRATION DATE: 31OCT2025, DEVICE MANUFACTURE DATE: 23NOV2021. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES D10: RETURNED TO MANUFACTURER ON: 11SEP2022. H6: INVESTIGATION SUMMARY ONE SAMPLE WAS PROVIDED TO OUR QUALITY TEAM FOR INVESTIGATION. AFTER VISUAL INSPECTION, IT WAS OBSERVED THAT THE MEMBRANE WAS NEVER ASSEMBLED ONTO THE CONNECTOR BODY, THEREFORE THE SYSTEM WAS OPEN AND LEAKED WHEN USED. A DEVICE HISTORY REVIEW WAS PERFORMED FOR SUSPECTED LOTS 2111212, 2111214, AND 2201207, NO DEVIATIONS OR NON-CONFORMANCES WERE IDENTIFIED DURING THE MANUFACTURING PROCESS THAT COULD HAVE CONTRIBUTED TO THIS ISSUE. FIVE RETAINED SAMPLES WERE USED FOR ADDITIONAL EVALUATION. ALL PRODUCT WAS VISUALLY INSPECTED AND VERIFIED THE MEMBRANES WERE PROPERLY ASSEMBLED. ASSEMBLY OF THE MEMBRANE IS PERFORMED MANUALLY. A DETECTION SYSTEM IS USED TO VERIFY THE PROPER WELDING AND LOCATION OF THE MEMBRANE. ALL QUALITY RECORDS VERIFY THE INSPECTIONS WERE PERFORMED ACCORDING TO PROCEDURE. WHILE WE CANNOT IDENTIFY A DIRECT ISSUE, IT WAS DETERMINED THIS INCIDENT IS DUE TO THE OPERATOR NOT PROPERLY WELDING THE MEMBRANE ONTO THE CONNECTOR BODY AND THE DETECTION SYSTEM ALSO NOT IDENTIFYING/REJECTING THE IMPACTED PIECE. A PROJECT WAS INITIATED TO FURTHER ADDRESS THIS ISSUE AND PREVENT ANY REOCCURRENCE. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED FOR FUTURE OCCURRENCE.

Description of Event or Problem · 0

IT WAS REPORTED WHILE USING BD PHASEAL ¿ L CONNECTOR C90J THE MEMBRANE SEPARATED AND LEAKAGE OCCURRED. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM JAPANESE TO ENGLISH: THIS IS A REPORT ABOUT SEPARATION OF THE MEMBRANE OF L-CONNECTOR, RESULTING IN CHEMO LEAKAGE. WHEN THE HCP DISENGAGED THE INJECTOR FROM THE L-CONNECTOR, THE MEMBRANE WAS SEPARATED FROM THE L-CONNECTOR, RESULTING IN LEAKAGE OF THE ANTICANCER AGENT.

Description of Event or Problem · 0

IT WAS REPORTED WHILE USING BD PHASEAL ¿ L CONNECTOR C90J THE MEMBRANE SEPARATED AND LEAKAGE OCCURRED. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM JAPANESE TO ENGLISH: THIS IS A REPORT ABOUT SEPARATION OF THE MEMBRANE OF L-CONNECTOR, RESULTING IN CHEMO LEAKAGE. WHEN THE HCP DISENGAGED THE INJECTOR FROM THE L-CONNECTOR, THE MEMBRANE WAS SEPARATED FROM THE L-CONNECTOR, RESULTING IN LEAKAGE OF THE ANTICANCER AGENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2391350 BD PHASEAL ¿ L CONNECTOR C90J INTRAVASCULAR ADMINISTRATION SET ONB BECTON DICKINSON, S.A. 2201207

Patients

Seq Age Sex Outcome Treatment
1 Unknown