FDA Adverse Event Death Summary report: N

ARROW PSI KIT: 8.5 FR X 4" (10 CM)

MDR report key: 15380286 · Received September 8, 2022

Report

Report Number
9680794-2022-00601
Event Type
Death
Date Received
September 8, 2022
Date of Event
June 27, 2022
Report Date
August 30, 2022
Manufacturer
ARROW INTERNATIONAL LLC
Product Code
DYB
PMA / PMN Number
K780532
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

QN#(B)(4). IT WAS INITIALLY REPORTED THAT 4 TO 5 KITS WERE USED AND FOUND TO BE TOO PLIABLE. ADDITIONAL INFORMATION WAS REQUESTED REGARDING THE COMPLAINT DESCRIPTION. THE CLINICIAN CLARIFIED ON (B)(6) 2022 THAT FOUR SHEATHS WERE BENT DURING USE. THEY WERE ALL USED ON THE SAME PATIENT. THE CLINICIAN ALSO MENTIONED A FIFTH SHEATH THAT WAS BENT; HOWEVER, SHE COULD NOT CONFIRM IF IT WAS USED ON A PATIENT. FIVE COMPLAINTS WERE OPENED TO CAPTURE ALL EVENTS. ASSOCIATED MDRS: 9680794-2022-00432, 9680794-2022-00433, 9680794-2022-00602, 9680794-2022-00603. COMPLAINT VERIFICATION TESTING COULD NOT BE PERFORMED AS IT WAS REPORTED THAT THE SAMPLE IS NOT AVAILABLE FOR RETURN. A DEVICE HISTORY RECORD REVIEW WAS PERFORMED AND NO RELEVANT FINDINGS WERE IDENTIFIED. WITHOUT THE DEVICE TO EVALUATE THE COMPLAINT COULD NOT BE CONFIRMED AND THE PROBABLE CAUSE COULD NOT BE DETERMINED FROM THE AVAILABLE INFORMATION. TELEFLEX WILL CONTINUE TO MONITOR AND TREND FOR REPORTS OF THIS NATURE. CORRECTED DATA.

Description of Event or Problem · 0

CUSTOMER COMPLAINT RECEIVED REPORTS CLINICIANS ATTEMPTED TO OBTAIN IV ACCESS ON A CRITICALLY ILL TRAUMA PATIENT USING 4 TO 5 INTRODUCER PERCUTANEOUS SHEATH 8.5FX10CM CUSTOM-UAH KITS WITHOUT SUCCESS, DUE TO THE PLIABILITY OF THE 8.5 FR. X 4" (10 CM) ARROW-FLEX RADIOPAQUE POLYURETHANE WITH INTEGRAL HEMOSTASIS VALVE/SIDE PORT AND TISSUE DILATOR. IT WAS REPORTED THE USER ATTEMPTED TO PLACE 4-5 SHEATHS WITHOUT SUCCESS AND EACH SHEATH COLLAPSED OR KINKED AND WAS NOT EFFECTIVE. IT WAS REPORTED THE PATIENT DIED ON (B)(6) 2022 DUE TO HYPOVOLEMIC CARDIAC SHOCK AND INABILITY TO REPLACE SIGNIFICANT FLUID LOSS. THE CUSTOMER ALLEGES THE DEVICE CONTRIBUTED TO THE PATIENT'S DEATH BECAUSE A CENTRAL LINE COULD NOT BE ESTABLISHED FOR TRANSFUSION. IT WAS REPORTED THE PATIENT HAD SUFFERED A SEVERE TRAUMA AND HAD SEVERE BLEEDING. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER INDICATES THE TRAUMA TO THE PATIENT WAS A SEVERE LACERATION TO THE NECK. THE SHEATH WAS ATTEMPTED TO BE PLACED IN THE SUBCLAVIAN AND FEMORAL ARTERIES. THE PATIENT WAS A MALE WITH NO KNOWN UNDERLYING CONDITIONS. THE CUSTOMER ALSO REPORTS NO DAMAGE TO THE SHEATH WAS OBSERVED BY THE SURGEON WHEN IT WAS FIRST PULLED OUT OF THE PACKAGING. IT WAS HOWEVER KINKING RIGHT AT THE ARTICULATED SECTION OF THE SHEATH NEAR THE HUB.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
280637 ARROW PSI KIT: 8.5 FR X 4" (10 CM) INTRODUCER CATHETER DYB ARROW INTERNATIONAL LLC 13F21J0927

Patients

Seq Age Sex Outcome Treatment
1 Male Death NOT REPORTED