FDA Adverse Event Malfunction Summary report: N

BD BBL¿ COLUMBIA CNA AGAR WITH 5% SHEEP BLOOD

MDR report key: 15374070 · Received September 7, 2022

Report

Report Number
1119779-2022-01173
Event Type
Malfunction
Date Received
September 7, 2022
Date of Event
August 28, 2022
Report Date
March 30, 2023
Manufacturer
BECTON, DICKINSON & CO. (SPARKS)
Product Code
JSJ
UDI-DI
10382902213533
PMA / PMN Number
PREAMENDMENT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
OH, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

MEDICAL DEVICE EXPIRATION DATE: UNKNOWN. MEDICAL DEVICE LOT #: UNKNOWN. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED. DEVICE MANUFACTURE DATE: UNKNOWN.

Additional Manufacturer Narrative · 0

H.6 INVESTIGATION SUMMARY: DURING MANUFACTURING OF MATERIAL 221353, MEDIA IS FORMULATED AND SENT THROUGH A HIGH TEMPERATURE SHORT TIME STERILIZER TO REMOVE BIOBURDEN. THE PETRI DISHES ARE SUBJECTED TO UV RADIATION TO DECREASE BIOBURDEN. THE PETRI DISHES ARE FILLED IN A POSITIVE PRESSURE HEPA FILTERED ENVIRONMENT. THE FILLED PLATES ARE COOLED AND IMMEDIATELY WRAPPED INTO SLEEVES TO DECREASE THE INTRODUCTION OF MICROBES. SLEEVES ARE THEN PACKAGED INTO CARTONS AND THEN TRANSFERRED TO A REFRIGERATED TRUCK (2 TO 8 DEGREES C) FOR SHIPMENT TO THE DISTRIBUTOR. BD DISTRIBUTORS ARE PROVIDED WITH THE STORAGE GUIDELINES FOR THE SHIPPING AND HANDLING OF BD MEDIA OF 2 TO 8 DEGREES C IN A DARK PLACE. THE RELEASE TESTING THAT IS PERFORMED ON THIS PRODUCT DOES INCLUDE PHYSICAL ATTRIBUTE TESTING. A SAMPLE OF PLATES ARE INCUBATED AT 25 DEGREES C AND AT 35 DEGREES C FOR APPROXIMATELY 72 HOURS. THEY ARE TESTED FOR PHYSICAL ATTRIBUTES PRIOR TO RELEASE TO ENSURE THAT THEY CONFORM TO PRODUCT SPECIFICATIONS. ONE PHOTO WAS RECEIVED FOR INVESTIGATION OF THIS COMPLAINT. THE PHOTO SHOWS THE BOTTOM OF A MEDIUM RED AGAR PLATE WITH NO PLATE PRINT. NO BD PRODUCT LABELS ARE IN THE PHOTO FOR BATCH VERIFICATION. NO RETURN SAMPLES WERE RECEIVED, AND NO BATCH NUMBER WAS PROVIDED FOR INVESTIGATION. RETENTION SAMPLES CANNOT BE EVALUATED WITHOUT A SPECIFIC BATCH NUMBER. TRENDING WAS PERFORMED ON THE APPROPRIATE QUALITY DATABASES AND NO TRENDS FOR MISSING PLATE PRINT WERE FOUND IN THE LAST 12 MONTHS. BD WILL CONTINUE TO TREND FOR THIS ISSUE. THIS COMPLAINT CANNOT BE CONFIRMED.

Description of Event or Problem · 0

IT WAS REPORTED BY THE CUSTOMER THAT THEY RECEIVED BD¿ COLUMBIA CNA AGAR WITH 5% SHEEP BLOOD THAT WAS UNMARKED WITH PLATE TYPE/LOT. THERE WAS ONE OCCURRENCE IN THIS EVENT WITH NO PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE CUSTOMER: "REPORTED UNMARKED WITH PLATE TYPE/LOT".

Description of Event or Problem · 0

IT WAS REPORTED BY THE CUSTOMER THAT THEY RECEIVED BD¿ COLUMBIA CNA AGAR WITH 5% SHEEP BLOOD THAT WAS UNMARKED WITH PLATE TYPE/LOT. THERE WAS ONE OCCURRENCE IN THIS EVENT WITH NO PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE CUSTOMER: "REPORTED UNMARKED WITH PLATE TYPE/LOT".

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
283616 BD BBL¿ COLUMBIA CNA AGAR WITH 5% SHEEP BLOOD CULTURE MEDIA, SELECTIVE AND NON-DIFFERENTIAL JSJ BECTON, DICKINSON & CO. (SPARKS) 221353 10382902213533

Patients

Seq Age Sex Outcome Treatment
1 Unknown