FDA Adverse Event Injury Summary report: N

EMPOWR HIP

MDR report key: 15365306 · Received September 6, 2022

Report

Report Number
1644408-2022-01178
Event Type
Injury
Date Received
September 6, 2022
Date of Event
August 29, 2022
Report Date
September 6, 2022
Manufacturer
ENCORE MEDICAL L.P.
Product Code
LPH
UDI-DI
00190446309772
PMA / PMN Number
K190057
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

EXPIRATION DATE: 03/29/2027 (29-MAR-2027). THE REASON FOR THIS REVISION SURGERY WAS REPORTED AS DEVELOPMENT OF SEROMA IN HIP. THE PREVIOUS SURGERY AND THE SURGERY DETAILED IN THIS EVENT OCCURRED 3 MONTHS APART. THE HEALTHCARE PROFESSIONAL INDICATED THERE WAS NO DELAY IN SURGERY AND ANOTHER SUITABLE DEVICE WAS AVAILABLE FOR USE. THE REVISION SURGERY WAS COMPLETED AS INTENDED. THE DEVICES WERE DISPOSED OF AT HOSPITAL AND NOT MADE AVAILABLE TO DJO SURGICAL FOR EXAMINATION. A REVIEW OF THE DEVICE HISTORY RECORDS (DHR) SHOW THAT THE REPORTED COMPONENTS USED IN THE PREVIOUS SURGERY, WHEN RELEASED FOR USE, MET DESIGN AND MANUFACTURING REQUIREMENTS. THERE WERE NO NON-CONFORMING MATERIAL REPORTS (NCMR) ASSOCIATED WITH THE PRODUCTS THAT MAY HAVE CONTRIBUTED TO THE REPORTED EVENT. THE DEVICES WERE VERIFIED TO HAVE GONE THROUGH AN ACCEPTABLE STERILIZATION PROCESS AND WERE WITHIN ITS EXPIRATION DATE AT THE TIME OF THE PREVIOUS SURGERY. CUSTOMER COMPLAINT HISTORY OF THE REPORTED DEVICES SHOWED NO PRESENT TRENDS OR ON-GOING ISSUES THAT ARE NEEDING A REVIEW. THE ROOT CAUSE OF THIS COMPLAINT WAS A REVISION SURGERY DUE TO DEVELOPMENT OF SEROMA IN HIP. THERE WERE NO FINDINGS DURING THIS EVALUATION THAT INDICATE THE REPORTED DEVICES WERE DEFECTIVE. NO INFORMATION WAS SUBMITTED WITH THE COMPLAINT REGARDING PRE-EXISTING CONDITIONS OF THE PATIENT OR ANY ACTIVITIES THE PATIENT WAS INVOLVED IN THAT MAY HAVE CONTRIBUTED TO THE EVENT. THERE ARE MULTIPLE FACTORS THAT MAY ALSO CONTRIBUTE TO AN EVENT THAT ARE OUTSIDE THE CONTROL OF DJO SURGICAL. THERE ARE NO INDICATIONS OF A PRODUCT OR PROCESS ISSUE AFFECTING IMPLANT SAFETY OR EFFECTIVENESS. ADDITIONAL REPORTING ON THIS EVENT WILL BE PROVIDED AS A SUPPLEMENTAL REPORT TO THIS DOCUMENT IF IT BECOMES AVAILABLE.

Description of Event or Problem · 0

REVISION SURGERY - PATIENT DEVELOPED SOME SORT OF SEROMA IN HIS HIP. IRRIGATION AND DRAINAGE WAS DONE WITH HEADLINER EXCHANGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2852053 EMPOWR HIP EMPOWR ACETABULAR SYSTEM, LINER, 10° HOODED, HXE+, 36G LPH ENCORE MEDICAL L.P. 942-01-36G 623Z1063 00190446309772

Patients

Seq Age Sex Outcome Treatment
1 57 YR Male Required Intervention 400-03-363 LOT 868B1418