HEARTMATE 3 LEFT VENTRICULAR ASSIST SYSTEM
Report
- Report Number
- 2916596-2022-13017
- Event Type
- Injury
- Date Received
- September 1, 2022
- Date of Event
- January 1, 2019
- Report Date
- February 22, 2023
- Manufacturer
- THORATEC CORPORATION
- Product Code
- DSQ
- PMA / PMN Number
- P160054
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
NO FURTHER INFORMATION WAS PROVIDED. A SUPPLEMENTAL REPORT WILL BE SUBMITTED ONCE THE MANUFACTURER¿S INVESTIGATION IS COMPLETED.
THIS REPORT WAS DETERMINED TO BE SUPPLEMENTAL TO MFR REPORT # 2916596-2019-04412. INVESTIGATION FINDINGS WILL BE REPORTED UNDER MFR REPORT # 2916596-2019-04412.
IT WAS ORIGINALLY REPORTED THROUGH THE RESEARCH ARTICLE ¿OUTFLOW GRAFT OBSTRUCTION IN PATIENTS WITH THE HM 3 LVAD: A PERCUTANEOUS APPROACH¿ UNDER MANUFACTURER REPORT NUMBER 2916596-2019-04412 THAT HEARTMATE (HM) 3 MAY BE RELATED TO OUTFLOW GRAFT OBSTRUCTION (OGO). A TOTAL OF 85 PATIENTS IMPLANTED WITH HM3 BETWEEN 2015 AND 2020 WERE INCLUDED IN THIS RETROSPECTIVE STUDY. ONE 54-YEAR-OLD WOMAN PRESENTED WITH DYSPNEA AND LOW-FLOW ALARMS 13 MONTHS AFTER HM3 IMPLANTATION. SHE HAD SUB-THERAPEUTIC INTERNATIONAL NORMALIZED RATIO (INR), AND WAS PLACED ON INTRAVENOUS HEPARIN. AN INVASIVE HEMODYNAMIC STUDY SHOWED ELEVATED BIVENTRICULAR FILLING PRESSURES WITH NO EFFECT OF PROGRESSIVE SPEED INCREMENTS ON PULMONARY CAPILLARY WEDGE PRESSURE (PCWP). COMPUTED TOMOGRAPHY ANGIOGRAPHY (CTA) OF THE CHEST SHOWED A SMOOTH FILLING DEFECT WITHIN THE OUTFLOW GRAFT (OG) THOUGHT TO REPRESENT COMPRESSION VERSUS TWISTING OF THE OG. TRANSTHORACIC ECHOCARDIOGRAM (TTE) SHOWED THE ATRIAL VALVE (AV) OPENING WITH EVERY BEAT AND MILD¿MODERATE MITRAL REGURGITATION (MR). INVASIVE ¿GRAFTOGRAPHY¿ VIA THE RIGHT FEMORAL ARTERY (RFA) SHOWED DIFFUSE NARROWING ALONG THE EXTENSION OF THE BEND RELIEF (BR), SUGGESTIVE OF OG EXTERNAL COMPRESSION WITH APPEARANCE OF A POSSIBLE TWIST. REPEAT STERNOTOMY WAS PERFORMED WITH UNTWISTING AND CLIP PLACEMENT. BIOMATERIAL BETWEEN THE OG AND THE BR WAS VISUALIZED AND REMOVED. REPEAT RIGHT HEART CATHETERIZATION (RHC) SHOWED NORMAL FILLING PRESSURES AND REPEAT TTE SHOWED DECOMPRESSED LEFT VENTRICLE AND INTERMITTENT AV OPENING. THE PATIENT WAS DISCHARGED ON WARFARIN AND ASPIRIN.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2587731 | HEARTMATE 3 LEFT VENTRICULAR ASSIST SYSTEM | VENTRICULAR (ASSIST) BYPASS | DSQ | THORATEC CORPORATION | 106524 | 6036878 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 52 YR | Female | Required Intervention| H |