VICRYL PLUS POLYGLACTIN 910 SUTURE
Report
- Report Number
- 2210968-2022-06767
- Event Type
- Malfunction
- Date Received
- August 18, 2022
- Date of Event
- August 3, 2022
- Report Date
- September 26, 2022
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K181652
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
(B)(4). THIS IS A COMBINATION PRODUCT, AND THE EVENT HAS BEEN REVIEWED FOR BOTH THE SUTURE AND THE TRICLOSAN. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ATTEMPTS HAVE BEEN MADE TO RETRIEVE THE DEVICE. TO DATE THE DEVICE HAS NOT BEEN RETURNED. IF THE DEVICE OR FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. ADDITIONAL INFORMATION WAS REQUESTED, AND THE FOLLOWING WAS OBTAINED VIA: WAS THERE ANY ADVERSE CONSEQUENCE ASSOCIATED WITH THE PATIENT? NO ANY ADVERSE CONSEQUENCES. TRADE NAME - IRGACARE®. ACTIVE INGREDIENT(S) ¿ TRICLOSAN. DOSAGE FORM ¿ SUTURE/SOLID/PARENTERAL. STRENGTH ¿ = 275 ¿G/M. EVENTS REPORTED VIA: 2210968-2022-06768 AND 2210968-2022-06766.
PRODUCT COMPLAINT # (B)(4). DATE SENT TO THE FDA: 9/26/2022. THIS IS A COMBINATION PRODUCT, AND THE EVENT HAS BEEN REVIEWED FOR BOTH THE SUTURE AND THE TRICLOSAN. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. H6 COMPONENT CODE: G07002 NO DEVICE PROBLEM FOUND. ADDITIONAL INFORMATION: D4, D9, H3, H4, H6. H3 INVESTIGATIONAL SUMMARY: COMPLAINT SAMPLE: 1 OPENED UNIT OF ACTUAL COMPLAINT SAMPLE FOIL ALONG WITH ZIPPER TRAY AND LID RECEIVED FOR INVESTIGATION FOR CODE VP2443 LOT T1005. IMPACTED SUTURE AND NEEDLE WAS NOT RECEIVED FOR INVESTIGATION. AS THE COMPLAINT SAMPLE RECEIVED IN OPEN CONDITION FURTHER INVESTIGATION ON COMPLAINT SAMPLE CANNOT BE PERFORMED EXCEPT VISUAL INSPECTION. THE FOIL PACK WAS INSPECTED UNDER A 10 X MAGNIFICATION FOR ANY DAMAGE AND SHOWED A MULTITUDE OF WRINKLES OVER THE WHOLE FOIL ALONG WITH SEVERAL PINHOLES AT BOTTOM CAVITY SIDE OF THE PACKS WERE OBSERVED. BATCH RECORD REVIEW: AS A PART OF FURTHER INVESTIGATION BATCH MANUFACTURING RECORD WAS REVIEWED FOR CODE VP2443 LOT T1005. THE BATCH MANUFACTURING RECORD WAS REVIEWED FOR ANY PROCESS DEVIATION, BUT NO DEVIATION WAS OBSERVED. FINISHED GOOD RECORD WAS REVIEWED FOR TENSILE STRENGTH VALUE AND NEEDLE PULL-OFF VALUE AT RELEASE AND FOUND TO MEET THE SPECIFICATION. FROM THE BATCH RECORD REVIEW, IT HAS BEEN OBSERVED THAT THERE WAS NO ISSUE RELATED TO THE SUTURE QUALITY AND PROCESSING OF THIS INCIDENT LOT. RETAIN SAMPLE: FIVE RETAIN SAMPLES OF INCIDENT CODE VP2443 LOT T1005 WERE RETRIEVED FOR ANALYSIS. THE PRIMARY PACKS OF RETAIN SAMPLES WERE VISUALLY INSPECTED FOR ATTRIBUTE DEFECTS LIKE PSEUDO SEAL, PIN HOLE, PRODUCT IN SEAL, PRESS MARKS ON PACK BUT NO SUCH DEFECTS WERE OBSERVED. THE PRIMARY PACKS WERE OPENED, AND SUTURES AND NEEDLES WERE FOUND INTACT. THE SUTURES WERE PHYSICALLY INSPECTED FOR ANY ATTRIBUTE DEFECTS LIKE KINKS, WEAK SPOTS, BROKEN PIECE, FRAY, BRITTLENESS, DETACHED NEEDLES BUT NO SUCH DEFECTS WERE OBSERVED. THE NEEDLES WERE INSPECTED FOR ANY ATTRIBUTE DEFECTS LIKE BEND, CRACKED BARREL, FINS BUT NO SUCH DEFECTS WERE OBSERVED. THE RETAIN SAMPLES WERE TESTED FOR KNOT PULL TEST AND FOUND TO MEET THE SPECIFICATION. AS THE COMPLAINT IS RELATED TO PERFORMANCE-BREAKAGE SUTURE, KNOT PULL TENSILE STRENGTH TEST IS APPLICABLE & MEASURABLE PARAMETER. KNOT PULL TENSILE STRENGTH TEST WAS PERFORMED OVER FIVE RETAIN SAMPLES TO CHECK THE BEHAVIOR OF THE SUTURE MATERIAL. THE AVERAGE KNOT PULL TENSILE STRENGTH VALUE OF THE RETAIN SAMPLE WAS FOUND TO BE 14.20 N AND VALUE AT THE TIME OF FINISHED GOOD RELEASE WAS FOUND TO BE 13.85 N WHICH MEETS THE USP AVERAGE KNOT PULL TENSILE STRENGTH REQUIREMENT I.E. NLT 9.32 N. ALL THE INDIVIDUAL AS WELL AS AVERAGE KNOT PULL TENSILE STRENGTH VALUES OF RETAIN SAMPLE WERE FOUND TO MEET THE USP SPECIFICATION REQUIREMENTS. THIS ANALYSIS SHOWS THAT THERE WAS NO ISSUE RELATED TO PROCESSING OF THE LOT. ALL THE VALUES ARE WITHIN THE CONTROL LIMITS. THE REPORTED INCIDENT WAS ONE AND ISOLATED CASE FOR CODE VP2443 LOT T1005 NO OTHER EVENT WAS REPORTED FOR SAME DESCRIPTION FROM OTHER PARTS OF COUNTRY. THE DETECTED BREAKAGE OF SUTURE ISSUE MAY HAVE BEEN OBSERVED DUE TO INGRESS OF HUMIDITY THROUGH THE OBSERVED PINHOLES¿. THE OBSERVED PIN HOLES MIGHT HAVE GENERATED DURING IMPROPER STORAGE AND HANDLING OF THE PRODUCT. TRADE NAME - IRGACARE®. ACTIVE INGREDIENT(S) ¿ TRICLOSAN. DOSAGE FORM ¿ SUTURE/SOLID/PARENTERAL. STRENGTH ¿ = 275 G/M, PRODUCT COMPLAINT # (B)(4). DATE SENT TO FDA: 9/26/2022. CORRECTED INFORMATION: D1, D2A, D4, G4. THIS IS A COMBINATION PRODUCT, AND THE EVENT HAS BEEN REVIEWED FOR BOTH THE SUTURE AND THE TRICLOSAN. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON (B)(6) 2022 AND SUTURE WAS USED. DURING THE PROCEDURE, THE SUTURE BROKE. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2791508 | VICRYL PLUS POLYGLACTIN 910 SUTURE | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. | T1005 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |