FDA Adverse Event Malfunction Summary report: N

COOLSCULPTING SYSTEM

MDR report key: 15214600 · Received August 11, 2022

Report

Report Number
3007215625-2022-01203
Event Type
Malfunction
Date Received
August 11, 2022
Date of Event
May 30, 2022
Report Date
December 5, 2023
Manufacturer
ALLERGAN PLEASANTON
Product Code
OOK
PMA / PMN Number
K160259
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

FIELD SERVICE WAS PERFORMED. EXTERNAL VISUAL INSPECTION: OUTSIDE LIQUID COOLANT STICK AND DUSTY. LEFT AND RIGHT-SIDE LOWER PANEL SCRATCH. OUTSIDE LOWER BASE SCRATCH. INCOMING TEST: I WAS PERFORMED INSPECTION, DIAGNOSTIC TESTING WITH RMA ADAPTER AND APPLICATOR RMA UNIT TURN ON RUNNING WELL INTERNAL INSPECTION: INTERNAL THE INSPECTION MEASURE UPPER AND LOWER BOTH 12V POWER SUPPLY AND CHECK ALL CABLES TO ENSURE SECURE WITH NO PROBLEM ALL CABLE LOOKING GOOD SECURE. I FOUND LIQUID COOLANT LEAK INSIDE THE UPPER. SUMMARY OF REPAIR DETAIL: UPDATE BOARDS OF UPPER UNIT. RE TIGHTEN CHILLER TUBE. RETEST AND CLEAN UP THE SYSTEM. ROOT CAUSE: I CONFIRM THE COSTUMER¿S COMPLAINT. RE TIGHTEN CHILLER TUBE. RETEST. UNIT RUN WELL. PARTS REPLACED: FOR LOWER: 200179 BOTTLE COOLANT BRZ-RP1-DLC-001 STANDALONE CRATE LOWER EN11955 CU BAG 206263 FILTER EN15643 RIGHT LOWER PANEL EN15644 LEFT LOWER PANEL. FOR UPPER: BRZ-RP1-DUC-001 CRATE UPPER EN11955 CU BAG 200455 COMPUTER BASE BOARD EN10606 CF CARD 200498 CONTROL INTERFACE BOARD. CLEAN UP THE SYSTEM WITH ALPHA WIPES PAINT TOUCHUP CYCLE POWER TESTED 3 MINS QUICK ENGINEERING CHECK PROFILE WAS RUN TO VERIFY PROPER OPERATION. THE CYCLE COMPLETED WITHOUT ERROR. 45MIN CYCLE POWER MFG BUN IN TESTED GOOD 80 HOURS DURATION TEST RUNNING 3 HOURS COMPLETE TESTED GOOD NO SHOW UP ANY ERROR ANALYZER TESTING SHOW ALL CHANNEL 1-6 ARE GOOD IN TEMPERATURE, AND TEC DATA. CURRENTS ARE GOOD ADDITIONAL TESTS: CHILLER DIAGNOSTIC TEST: PASSED VACUUM DIAGNOSTIC TEST: PASSED PAGING SYSTEM TEST: PASSED TOUCHSCREEN TEST & CALIBRATION: PASSED PERFORMED FINAL TEST PASS. BASED ON THE INFORMATION CURRENTLY AVAILABLE, TECHNICAL REVIEW, AND LABORATORY INSPECTION, ALTHOUGH NO ADVERSE EVENT WAS REPORTED, THERE IS THE POSSIBILITY OF: SKIN IRRITATION/ HYPERSENSITIVITY, ELECTRIC SHOCK, THERMAL INJURY FROM HOT OR COLD COOLANT, BRUISING FROM SLIP HAZARD, AND FRACTURE. IT CAN BE CONCLUDED THAT THE LEAKAGE OF COOLANT FROM THE FAILURE IDENTIFIED POSE LOW RISKS OF DISCUSSED HARMS AND MODERATE RISK OF FRACTURE. A SUPPLEMENTAL REPORT WILL BE SUBMITTED IF AND WHEN ADDITIONAL INFORMATION IS OBTAINED.

Additional Manufacturer Narrative · 0

CORRECTED DATA: D1.

Description of Event or Problem · 0

ALLERGAN AESTHETICS RECEIVED A REPORT OF A LEAK WITH THE COOLSCULPTING CONTROL UNIT. THERE WAS NO PATIENT OR PROVIDER SAFETY IMPACT.

Description of Event or Problem · 0

ALLERGAN AESTHETICS RECEIVED A REPORT OF A LEAK WITH THE COOLSCULPTING CONTROL UNIT. THERE WAS NO PATIENT OR PROVIDER SAFETY IMPACT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
326362 COOLSCULPTING SYSTEM DERMAL COOLING PACK/VACUUM/MASSAGER OOK ALLERGAN PLEASANTON NI

Patients

Seq Age Sex Outcome Treatment
1 Unknown