INFANT DUAL HEATED EVAQUA2 BREATHING CIRCUIT
Report
- Report Number
- 9611451-2022-00729
- Event Type
- Malfunction
- Date Received
- August 8, 2022
- Date of Event
- August 3, 2022
- Report Date
- August 8, 2022
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LIMITED
- Product Code
- BZE
- PMA / PMN Number
- K020332
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
(B)(4). WE ARE CURRENTLY IN THE PROCESS OF COMPLETING OUR INVESTIGATION. WE WILL PROVIDE A FOLLOW UP REPORT UPON COMPLETION OF OUR INVESTIGATION.
(B)(4). CORRECTED DATA: SECTION B5 DESCRIBE EVENT OR PROBLEM: A DISTRIBUTOR REPORTED ON BEHALF OF A HEALTHCARE FACILITY IN CHINA THAT THE EXPIRATORY LIMB OF A RT266 INFANT DUAL HEATED EVAQUA2 BREATHING CIRCUIT WAS FOUND DAMAGED. SECTION D1 BRAND NAME: INFANT DUAL HEATED EVAQUA2 BREATHING CIRCUIT. SECTION D2 COMMON DEVICE NAME: BZE, PRODUCT CODE: BZE. SECTION D4 MODEL #; CATALOG #: RT266; RT266. METHOD: THE COMPLAINT RT266 INFANT DUAL-HEATED EVAQUA2 BREATHING CIRCUIT WAS RETURNED TO FISHER & PAYKEL HEALTHCARE (F&P) NEW ZEALAND WHERE IT WAS VISUALLY INSPECTED AND ANALYZED. RESULTS: VISUAL INSPECTION OF THE RETURNED COMPLAINT DEVICE REVEALED THAT THE EVAQUA2 TUBE WAS FOUND DEGRADED IN SEVERAL AREAS. FOURIER-TRANSFORM INFRARED SPECTROSCOPY (FTIR) ANALYSIS WAS PERFORMED AND RESULTS SHOWED THAT THE EVAQUA2 TUBE MATERIAL HAS BEEN CHEMICALLY ATTACKED. CONCLUSION: BASED ON THE FTIR ANALYSIS, THE EVAQUA2 TUBE DEGRADED DUE TO BEING CHEMICALLY ATTACKED. ALL RT266 INFANT DUAL-HEATED EVAQUA2 BREATHING CIRCUITS ARE VISUALLY INSPECTED AND PRESSURE AND FLOW TESTED DURING PRODUCTION, AND THOSE THAT FAIL ARE REJECTED. THE SUBJECT INFANT BREATHING CIRCUIT WOULD HAVE MET THE REQUIRED SPECIFICATIONS AT THE TIME OF PRODUCTION. OUR USER INSTRUCTIONS THAT ACCOMPANY THE RT266 INFANT DUAL-HEATED EVAQUA2 BREATHING CIRCUIT STATE THE FOLLOWING: "DO NOT SOAK, WASH, STERILIZE, OR REUSE THIS PRODUCT. AVOID CONTACT WITH CHEMICALS, CLEANING AGENTS, OR HAND SANITIZERS." "DO NOT USE MEDICATIONS CONTAINING TYLOXAPOL (SUCH AS TACHOLIQUIN) AS THIS MAY DAMAGE THE TUBING AND LEAD TO A LOSS OF VENTILATION PRESSURE." "PERFORM A PRESSURE AND LEAK TEST ON THE BREATHING SYSTEM AND CHECK FOR OCCLUSIONS BEFORE CONNECTING TO A PATIENT." "ENSURE APPROPRIATE VENTILATOR OR FLOW SOURCE ALARMS ARE SET BEFORE CONNECTING BREATHING SET TO PATIENT."
A DISTRIBUTOR REPORTED ON BEHALF OF A HEALTHCARE FACILITY IN CHINA THAT THE EXPIRATORY LIMB OF A RT330 OPTIFLOW JUNIOR TUBING KIT WAS FOUND DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.
A DISTRIBUTOR REPORTED ON BEHALF OF A HEALTHCARE FACILITY IN CHINA THAT THE EXPIRATORY LIMB OF A RT266 INFANT DUAL HEATED EVAQUA2 BREATHING CIRCUIT WAS FOUND DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1989076 | INFANT DUAL HEATED EVAQUA2 BREATHING CIRCUIT | BZE | BZE | FISHER & PAYKEL HEALTHCARE LIMITED | RT266 | NOT PROVIDED | |
| 2148373 | INFANT DUAL HEATED EVAQUA2 BREATHING CIRCUIT | BZE | BZE | FISHER & PAYKEL HEALTHCARE LIMITED | RT266 | NOT PROVIDED |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |