FDA Adverse Event Injury Summary report: N

UNK SHOULDER HUMERAL EPIPHYSIS DELTA XTEND

MDR report key: 15138918 · Received August 1, 2022

Report

Report Number
1818910-2022-14612
Event Type
Injury
Date Received
August 1, 2022
Date of Event
January 1, 2022
Report Date
August 1, 2022
Manufacturer
DEPUY IRELAND - 9616671
Product Code
KWS
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). INVESTIGATION SUMMARY : NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. THIS COMPLAINT WAS OPENED TO DOCUMENT COMPLAINTS DERIVED THROUGH A JOURNAL ARTICLE REVIEW. FOLLOW-UPS WERE DONE TO TRY AND OBTAIN ADDITIONAL INFORMATION FROM THE AUTHOR OF THE JOURNAL ARTICLE. NO FURTHER INFORMATION WAS RECEIVED. DEVICE HISTORY LOT : A MANUFACTURING RECORD EVALUATION (MRE), WAS NOT POSSIBLE BECAUSE THE REQUIRED LOT CODE WAS NOT PROVIDED.

Description of Event or Problem · 0

THIS COMPLAINT IS FROM A LITERATURE SOURCE. LITERATURE CITATION: HOLSCHEN M, KÖRTING M, KHOURDAJI P, BOCKMANN B, SCHULTE TL, WITT KA, STEINBECK J. TREATMENT OF PROXIMAL HUMERUS FRACTURES USING REVERSE SHOULDER ARTHROPLASTY: DO THE INCLINATION OF THE HUMERAL COMPONENT AND THE LATERAL OFFSET OF THE GLENOSPHERE INFLUENCE THE CLINICAL OUTCOME AND TUBEROSITY HEALING? ARCH ORTHOP TRAUMA SURG. 2022 JAN 3. DOI: 10.1007/S00402-021-04281-5. EPUB AHEAD OF PRINT. PMID: 34977963. OBJECTIVE/METHODS/STUDY DATA: FOR THIS RETROSPECTIVE COMPARATIVE ANALYSIS, 58 OUT OF 66 PATIENTS TREATED BY REVERSE TOTAL SHOULDER ARTHROPLASTY FOR PROXIMAL HUMERUS FRACTURES WERE INCLUDED. THE MINIMUM FOLLOW-UP WAS 24 MONTHS. THIRTY (M=3, F=27; MEAN AGE 78 YEARS; MEAN FU 35 MONTHS, RANGE 24¿58 MONTHS) WERE TREATED WITH A STANDARD 155° HUMERAL COMPONENT AND A GLENOSPHERE WITHOUT LATERAL OFFSET (GROUP A), WHILE 28 PATIENTS (M=2, F=26; MEAN AGE 79 YEARS; MEAN FU 30 MONTHS, RANGE 24¿46 MONTHS) WERE TREATED WITH A 135° HUMERAL COMPONENT AND A GLENOSPHERE WITH A 4 MM LATERAL OFFSET (GROUP B). GROUP A CONSISTED OF DEPUY XTEND IMPLANTS AND GROUP B WERE NON DEPUY. THIS COMPLAINT CAPTURES THE NOTED ADVERSE EVENTS WITHIN GROUP A. CEMENT MANUFACTURER IS NOT IDENTIFIED. FIGURE 4 IS A RADIOGRAPHIC IMAGE OF A 77 YEAR OLD FEMALE PATIENT WITH IMPLANTS, DEVICE MANUFACTURER IS NOT IDENTIFIED, AND NO ADVERSE EVENT NOTED. FIGURE 5 IS A RADIOGRAPHIC IMAGES OF 80 YEAR OLD FEMALE PATIENT WITH IMPLANTS, DEVICE MANUFACTURER IS NOT IDENTIFIED; NOTED IS SCAPULAR NOTCHING AND STRESS SHIELDING AT THE PROXIMAL LATERAL DIAPHYSIS. ADVERSE EVENT(S) AND PROVIDED INTERVENTIONS: QTY 1 MINOR NEUROLOGIC COMPLICATIONS WITH INTERMITTING HYPOESTHESIA OCCURRED. QTY 1 HEMATOMA REQUIRING REVISION. QTY 1 JOINT INSTABILITY REQUIRING REVISION - TREATED WITH A LARGER INLAY AND REMAINED STABLE AFTER REVISION. QTY 14 SCAPULAR NOTCHING. QTY 2 RADIOLUCENCY. QTY 1 STRESS SHIELDING. QTY 2 HETEROTOPIC OSSIFICATIONS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2941255 UNK SHOULDER HUMERAL EPIPHYSIS DELTA XTEND SHOULDER HUMERAL EPIPHYSIS KWS DEPUY IRELAND - 9616671

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention