FDA Adverse Event Malfunction Summary report: N

CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM

MDR report key: 15109089 · Received July 26, 2022

Report

Report Number
2029046-2022-01713
Event Type
Malfunction
Date Received
July 26, 2022
Date of Event
June 29, 2022
Report Date
September 10, 2022
Manufacturer
BIOSENSE WEBSTER INC
Product Code
DYB
UDI-DI
10846835016277
PMA / PMN Number
K170997
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GA, US
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 4. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY BIOSENSE WEBSTER INC., OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, BIOSENSE WEBSTER INC., OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REF. #: (B)(4).

Additional Manufacturer Narrative · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) ABLATION PROCEDURE WITH A CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM AND A HEMOSTATIC VALVE SEPARATION OCCURRED. IT WAS REPORTED THAT WHEN TRYING TO FLUSH THE CATHETER, IT WAS NOTICED THAT THE CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM WAS LEAKING BACK BLOOD. THE HEMOSTATIC VALVE HUB WAS CRACKED. THE CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM WAS REPLACED, AND THE ISSUE RESOLVED. THE PROCEDURE CONTINUED. THERE WAS NO PATIENT CONSEQUENCE. DEVICE EVALUATION DETAILS: ON 24-AUG-2022, THE PRODUCT WAS RETURNED TO BIOSENSE WEBSTER INC (BWI) FOR EVALUATION. THE EVALUATION HAS BEEN COMPLETED. VISUAL INSPECTION AND MICROSCOPIC EXAMINATION OF THE RETURNED DEVICE WERE PERFORMED FOLLOWING BWI PROCEDURES. VISUAL ANALYSIS REVEALED THAT THE HEMOSTATIC VALVE WAS DISLODGED INSIDE THE HUB COMPONENT. A MICROSCOPIC EXAMINATION OF THE HEMOSTATIC VALVE SURFACE SHOWED STRESS MARKS ON THE OUTER DIAMETER. THE STRESS MARKS SUGGEST THAT EXCESSIVE FORCE OR MANIPULATION WAS APPLIED DUE TO AN EXTREME OFF-AXIS ANGLE OF INSERTION. VALVE DISLODGEMENT OCCURS WHEN EXTREME OFF-AXIS ANGLES ARE PERFORMED DURING INSERTION WITH THE DILATOR, OUTSIDE OF WHAT IS RECOMMENDED IN THE ODP (OPTIMAL DEVICE PERFORMANCE GUIDE). A DEVICE HISTORY RECORD WAS PERFORMED FOR THE FINISHED DEVICE BATCH NUMBER, AND NO INTERNAL ACTIONS WERE IDENTIFIED. THE ISSUE REPORTED BY THE CUSTOMER WAS CONFIRMED. THE ODP CONTAINS THE FOLLOWING CAUTION: ALWAYS INSERT A DILATOR STRAIGHT INTO THE CENTER OF THE SHEATH¿S VALVE TO PREVENT DAMAGE TO THE VALVE. DO NOT INSERT A DILATOR AT AN ANGLE, AS DAMAGE TO THE SHEATH VALVE MAY OCCUR. AS PART OF THE QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REF. (B)(4).

Description of Event or Problem · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) ABLATION PROCEDURE WITH A CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM AND A HEMOSTATIC VALVE SEPARATION OCCURRED. IT WAS REPORTED THAT WHEN TRYING TO FLUSH THE CATHETER, IT WAS NOTICED THAT THE CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM WAS LEAKING BACK BLOOD. THE HEMOSTATIC VALVE HUB WAS CRACKED. THE CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM WAS REPLACED, AND THE ISSUE RESOLVED. THE PROCEDURE CONTINUED. THERE WAS NO PATIENT CONSEQUENCE. ADDITIONAL INFORMATION WAS LATER RECEIVED WHICH INDICATED IT WAS THE (WHITE) SAFETY VALVE THAT POPPED BACK INTO THE CLEAR HUB. THE HEMOSTATIC VALVE (GASKET) DID NOT BREAK INTO TWO OR MORE SEPARATE PIECES. THE HEMOSTATIC VALVE DID NOT BECOME DETACHED FROM THE SHEATH. AIR DID NOT ENTER THE PATIENT¿S BODY. THE ISSUE DID NOT REQUIRE PERCUTANEOUS, SURGICAL REMOVAL OR MEDICAL INTERVENTION. THE PATIENT HEMODYNAMICS WERE NOT COMPROMISED DUE TO BLEEDING AND THE APPROXIMATE VOLUME OF BLOOD THAT WAS LOST WAS UNKNOWN.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1926921 CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM INTRODUCER, CATHETER DYB BIOSENSE WEBSTER INC D138502 50000087 10846835016277

Patients

Seq Age Sex Outcome Treatment
1 Unknown 8.5F SHEATH WITH CURVE VIZ MDC