FDA Adverse Event Injury Summary report: N

UNKNOWN BEACON NEEDLE

MDR report key: 15067390 · Received July 20, 2022

Report

Report Number
3004904811-2022-00007
Event Type
Injury
Date Received
July 20, 2022
Date of Event
February 27, 2022
Report Date
July 20, 2022
Manufacturer
COVIDIEN LP BARRX
Product Code
FCG
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
DA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

LITERATURE: TITLE: ACCURACY AND CLINICAL OUTCOMES OF PANCREATIC EUS-GUIDED FINE-NEEDLE BIOPSY IN A CONSECUTIVE SERIES OF 852 SPECIMENS. SOURCE: DOI: 10.4103/EUS-D-21-00180. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

ACCORDING TO LITERATURE SOURCE OF STUDY PERFORMED FROM 2015 TO 2020, A RETROSPECTIVE STUDY OF 723 PATIENTS WERE EVALUATED FOR THE USE OF THE A NEEDLE FOR PANCREATIC ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE BIOPSY PROCEDURES WHICH CONSISTED OF 852 SAMPLES. ONE PATIENT DEVELOPED ACUTE PANCREATITIS 3 HOURS AFTER PROCEDURE AND WAS DISCHARGED TWO DAYS LATER, 28 PATIENTS HAD SELF-LIMITING LOCAL BLEEDING DURING THE PROCEDURE, 17 PATIENTS COMPLAINED OF ABDOMINAL PAIN AND WERE ALL DISCHARGED THE SAME DAY AS THE PROCEDURE, 40 PATIENTS WERE ADMITTED TO A HOSPITAL WITHIN 7 DAYS AFTER THE PROCEDURE AND THESE WERE LATE COMPLICATIONS AND 10 PATIENTS HAD IMMEDIATE COMPLICATIONS AVERAGE TIME ADMITTED WAS 7.9 DAYS. ONE PATIENT WAS ADMITTED FOR 114 DAYS, SUFFERING FROM SEVERE NECROTIC PANCREATITIS WITH ABSCESS UNDERGOING NECROSECTOMY, AND ADMISSION TO THE INTENSIVE CARE UNIT FOR A TOTAL OF 40 DAYS. ONE PATIENT WAS HOSPITALIZED FOR 25 DAYS WITH BLEEDING AND UNDERWENT GASTRODUODENOSCOPY IN GENERAL ANESTHESIA, SHOWING DUODENAL BLEEDING, MOST LIKELY CAUSED BY THE TRANS-DUODENAL ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE BIOPSY PROCEDURE AND WAS TREATED BY ENDOSCOPIC THERAPY ONLY AND 2 PATIENTS NEEDED INTERVENTION. 20 PATIENTS WITH ACUTE PANCREATITIS, 13 PATIENTS COMPLAINED WHO OF ABDOMINAL PAIN, 2 PATIENTS WITH SELF-LIMITING BLEEDING, 1 PATIENT WITH INFECTION, 1 PATIENT WITH SEPSIS AND 1 PATIENT WITH FEVER HAD BEEN HOSPITALIZED FOR AN AVERAGE OF 4.6 DAYS REQUIRING ONLY CONSERVATIVE TREATMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
358323 UNKNOWN BEACON NEEDLE BIOPSY NEEDLE FCG COVIDIEN LP BARRX UNKNOWN BEACON NEEDLE

Patients

Seq Age Sex Outcome Treatment
1 65 YR Male Hospitalization| R