640G INSULIN PUMP MMT-1711H
Report
- Report Number
- 2032227-2022-283479
- Event Type
- Malfunction
- Date Received
- July 13, 2022
- Date of Event
- November 26, 2016
- Report Date
- July 13, 2022
- Manufacturer
- MEDTRONIC PUERTO RICO OPERATIONS CO.
- Product Code
- OYC
- Removal / Correction Number
- Z-0958-2020
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
"THIS REPORT IS PART OF A RETROSPECTIVE REVIEW AND REMEDIATION EFFORTS IN RESPONSE TO A WARNING LETTER.RECALL: Z-0958-2020.(B)(4).THIS RECORD WAS CONVERTED. FOR ADDITIONAL INFORMATION ABOUT THE ANALYSIS, PLEASE SEE SAP.UNIT PASSED REWIND TEST, PRIME/SEATING TEST, BASIC OCCLUSION TEST, FORCESENSOR TEST, SLEEP CURRENT MEASUREMENT, ACTIVE CURRENT MEASUREMENT ANDSELFTEST. UNIT RECEIVED WITH MISSING RETAINER. UNABLE TO PERFORMDISPLACEMENT TEST AND OCCLUSION TEST DUE TO MISSING RETAINER. NOUNEXPECTED LOW BATTERY ALERTS NOTED DURING TESTING OR IN THE FORMATHISTORY FILE. PUMP ERROR 25 WAS PRESENT IN THE FORMAT HISTORY FILE ANDPUMP ERROR 25 WAS TRIGGERED WHEN THE LITHIUM BACKUP BATTERY (LOADEDVLITH) WAS LESS THAN 3.50V FOR 240 CONSECUTIVE MINUTES AS INDICATED INTHE POWER MANAGEMENT GRAPH DUE TO CONNECTOR RESISTANCE ISSUE (J6).CONNECTOR FOR J6 ON PCBA 1 WAS PROPERLY CONNECTED DURING VISUALINSPECTION. THE J6 CONNECTOR WAS DISCONNECTED AND RECONNECTED THENMONITORED FOR 2 DAYS WITH THE UNIT FUNCTIONING PROPERLY DURING TESTINGAS SHOWN IN THE POWER MANAGEMENT GRAPH. UNIT RECEIVED WITH MISSINGRESERVOIR TUBE O-RING, SCRATCHED CASING, MINOR SCRATCHES ON LCD WINDOW,PILLOWING KEYPAD OVERLAY AND DAMAGED KEYPAD OVERLAY TEMEDTRONIC, INC. (MEDTRONIC) IS SUBMITTING THIS REPORT TO COMPLY WITH 21 C.F.R. PART 803, THE MEDICAL DEVICE REPORTING REGULATION. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION IN THE TIME ALLOTTED AND HAS PROVIDED AS MUCH INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ""DEFECTS"" OR HAS ""MALFUNCTIONED"". THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA, TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REPORTING PURSUANT TO PART 803. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE IT BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT."
THIS COMPLAINT IS PART OF THE RETROSPECTIVE REVIEW AND REMEDIATION PER (B)(4), CLASS I AND II FIELD CORRECTIVE ACTION MDR REMEDIATION PLAN FOR DIABETES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1059734 | 640G INSULIN PUMP MMT-1711H | PUMP, INFUSION, INSULIN, TO BE USED WITH INVASIVE GLUCOSE SENSOR | OYC | MEDTRONIC PUERTO RICO OPERATIONS CO. | MMT-1711H |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |