FDA Adverse Event Malfunction Summary report: N

BD VACUTAINER® ECLIPSE¿ SIGNAL¿ BLOOD COLLECTION NEEDLE

MDR report key: 14951758 · Received July 7, 2022

Report

Report Number
9617032-2022-00616
Event Type
Malfunction
Date Received
July 7, 2022
Date of Event
June 8, 2022
Report Date
June 17, 2022
Manufacturer
BECTON, DICKINSON AND COMPANY (BD)
Product Code
JKA
PMA / PMN Number
UNKNOWN
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. INVESTIGATION SUMMARY: "MATERIAL #: 368837. LOT/BATCH #: 2062121. BD HAD NOT RECEIVED SAMPLES, BUT 3 PHOTOS WERE PROVIDED FOR INVESTIGATION. THE PHOTOS WERE REVIEWED AND THE INDICATED FAILURE MODE FOR LEAKAGE WAS OBSERVED AS BLOOD IS SEEN WITHIN THE HOLDER AND THE SLEEVE IS SEEN TO BE SIDE-PIERCED. ADDITIONALLY, 5 RETENTION SAMPLES FROM BD INVENTORY WERE EVALUATED BY FUNCTIONAL TESTING, EACH USED TO DRAW 5 TUBES, AND THE ISSUE OF LEAKAGE WAS NOT OBSERVED. BASED ON A REVIEW OF THE DEVICE HISTORY RECORD FOR THE INCIDENT LOT, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET. THERE WERE NO RELATED QUALITY ISSUES DURING MANUFACTURING OF THE PRODUCT. THIS COMPLAINT HAS BEEN CONFIRMED FOR THE INDICATED FAILURE MODE LEAKAGE. BD WAS NOT ABLE TO IDENTIFY A ROOT CAUSE FOR THE INDICATED FAILURE MODE. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS."

Description of Event or Problem · 0

IT WAS REPORTED WHEN USING THE BD VACUTAINER® ECLIPSE¿ SIGNAL¿ BLOOD COLLECTION NEEDLE LEAKAGE OCCURS AND THE THREAD OF THE NEEDLE IS MORE THAN THE VACUTAINER HOLDER. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER. THE CUSTOMER STATED: ¿A NUMBER OF PRICKER'S ARE HAVING PROBLEMS WITH THE NEEDLE (368837) AND THE VACUTAINER HOLDER(368872). LEAKAGE OCCURS AND THE THREAD OF THE NEEDLE IS MORE THAN THE VACUTAINER HOLDER. WHICH VACUTAINER HOLDER DO YOU RECOMMEND WITH THE SIGNAL 21X1.25 NEEDLE (368837)?¿.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2087320 BD VACUTAINER® ECLIPSE¿ SIGNAL¿ BLOOD COLLECTION NEEDLE BLOOD SPECIMEN COLLECTION DEVICE JKA BECTON, DICKINSON AND COMPANY (BD) 2062121

Patients

Seq Age Sex Outcome Treatment
1 Unknown