FDA Adverse Event Injury Summary report: N

ZENITH AAA ENDIOVASCULAR GRAFT ILIAC LEG

MDR report key: 1488693 · Received September 29, 2009

Report

Report Number
1820334-2009-00555
Event Type
Injury
Date Received
September 29, 2009
Date of Event
August 12, 2009
Report Date
September 2, 2009
Manufacturer
COOK, INC.
Product Code
MIH
PMA / PMN Number
P020018
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE ZENITH DEVICE HAS COMPLETED REQUIREMENTS SHOWING THE DEVICE MEETS THE PREDETERMINED REQUIREMENTS AND THAT THE REQUIREMENTS MEET THE NEEDS OF THE USER. EACH ZENITH DEVICE IS SHIPPED WITH INSTRUCTIONS FOR USE (IFU), LISTING THE INDICATIONS FOR USE, CONTRAINDICATIONS, WARNINGS & PRECAUTIONS, AND THE CORRECT DEPLOYMENT PROCEDURE. IN REGARDS TO THIS FAILURE MODE, THE IFU STATES THAT INACCURATE PLACEMENT OF THE GRAFT MAY RESULT IN AN INCREASED RISK OF ENDOLEAK AND/OR MIGRATION. THE FAILURE MODE ASSIGNED TO THIS INVESTIGATION IS "INACCURATE DEPLOYMENT". THIS IS BASED ON THE PROVIDED EVENT DESCRIPTION, SPECIFICALLY THAT THE USER DEPLOYED BOTH ILIAC LIMBS MORE PROXIMAL THAN INTENDED. ADDITIONALLY, THERE WAS NO MENTION OF THIS GRAFT MIGRATING, AS THERE WAS WITH THE OTHER LEG GRAFT. THE EVENT DESCRIPTION STATED THIS LEG GRAFT WAS UNSTABLY POSITIONED. AT THIS TIME, IT IS UNCLEAR HOW THAT IS DEFINED AND WHAT THE EFFECTS OF THAT WOULD BE. WE WILL CONTINUE TO MONITOR FOR SIMILAR INCIDENTS.

Description of Event or Problem · 1

A MALE UNDERWENT AAA REPAIR IN 2008. THE PROCEDURE CONSISTED OF PLACEMENT OF A ZENITH MAIN BODY, TWO ZENITH ILIAC LEGS, AND WAS CONDUCTED WITHOUT REPORTED INCIDENT. IN 2009, THE PATIENT UNDERWENT A SECONDARY PROCEDURE. THE PATIENT HAD VERY TORTUOUS ILIAC ARTERIES AND IN THE INITIAL PROCEDURE, THE PHYSICIAN COULD NOT VISUALIZE THE ORIGIN OF THE HYPOGASTRIC ARTERIES CLEARLY. THE PHYSICIAN ENDED UP DEPLOYING THE ILIAC LIMBS MORE PROXIMAL THAN INTENDED, BECAUSE HE DID NOT WANT TO RISK COVERING THE HYPOGASTRIC ARTERIES. THE PATIENT CAME IN FOR A ROUTINE FOLLOW UP AND THE PHYSICIAN NOTICED THAT THE LEFT ILIAC LIMB HAD RETRACTED PROXIMALLY INTO THE ANEURYSM SAC, BUT WITHOUT AN OBVIOUS TYPE 1B ENDOLEAK (180334-2009-00556). THE PHYSICIAN ELECTED TO EXTEND BOTH LIMBS, BECAUSE ON 3D DESTRUCTION THE RIGHT LIMB WAS ALSO UNSTABLY POSITIONED. THE PHYSICIAN LANDED BOTH EXTENSIONS EXACTLY AS INTENDED AT THE HYPOGASTRIC ARTERIES ON BOTH SIDES. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 ZENITH AAA ENDIOVASCULAR GRAFT ILIAC LEG MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH COOK, INC. NA 1921376

Patients

Seq Age Sex Outcome Treatment
1 40 YR Required Intervention