FDA Adverse Event Injury Summary report: N

UNKNOWN EMPRINT ANTENNA

MDR report key: 14801612 · Received June 24, 2022

Report

Report Number
3004962788-2022-00047
Event Type
Injury
Date Received
June 24, 2022
Date of Event
October 2, 2021
Report Date
June 24, 2022
Manufacturer
COVIDIEN LP - SUPERDIMENSION INC
Product Code
NEY
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AS
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

TITLE: HAEMOBILIA SECONDARY TO AN ARTERIO-BILIARY FISTULA: A RARE COMPLICATION OF INTRA OPERATIVE MICROWAVE ABLATION OF HEPATOCELLULAR CARCINOMA. SOURCE: JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY 65 (2021) 911-914. MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

ACCORDING TO THE LITERATURE OF HAEMOBILIA SECONDARY TO AN ARTERIO-BILIARY FISTULA: A RARE COMPLICATION OF INTRA OPERATIVE MICROWAVE ABLATION OF HEPATOCELLULAR CARCINOMA, A CASE REPORT DESCRIBES COMPLICATIONS EXPERIENCED BY A 58 YEAR-OLD WOMAN WITH HEPATOCELLULAR CARCINOMA AFTER UNDERGOING MICROWAVE ABLATION UTILIZING THE EMPRINT ABLATION SYSTEM AND 20 CM CATHETER. FOLLOWING THE ABLATION PROCEDURE, THE PATIENT¿S GALLBLADDER HAD TO BE SURGICALLY REMOVED DUE TO SUSPECTED HEMORRHAGE. 15 DAYS AFTER THE ABLATION PROCEDURE, THE PATIENT BEGAN EXPERIENCING FRANK RED RECTAL BLEEDING AND BECAME HEMODYNAMICALLY UNSTABLE. A CT WAS PERFORMED THAT SHOWED ACTIVE HEMORRHAGING INTO THE DUODENUM. A GASTROSCOPY AND ADDITIONAL CT SCAN CONFIRMED AN ARTERIOPORTAL FISTULA WHICH WAS REPAIRED WITH COIL EMBOLIZATION. THE PATIENT WAS DISCHARGED AFTER AN EXTENDED HOSPITAL STAY OF 36 DAYS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1072658 UNKNOWN EMPRINT ANTENNA SYSTEM, ABLATION, MICROWAVE AND ACCESSORIES NEY COVIDIEN LP - SUPERDIMENSION INC UNKNOWN EMPRINT ANTENNA

Patients

Seq Age Sex Outcome Treatment
1 Unknown Hospitalization| R