FDA Adverse Event Injury Summary report: N

GORE-TEX® VASCULAR GRAFT

MDR report key: 14776865 · Received June 22, 2022

Report

Report Number
2017233-2022-03035
Event Type
Injury
Date Received
June 22, 2022
Date of Event
September 27, 2020
Report Date
June 22, 2022
Manufacturer
W. L. GORE & ASSOCIATES, INC.
Product Code
DSY
PMA / PMN Number
K802095
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

LITERATURE CITATION: FUJITA S, YAMAGISHI M, MIYAZAKI T, MAEDA Y, ITATANI K, YAMAMOTO Y ET AL. LONG-TERM RESULTS OF LARGE-CALIBRE EXPANDED POLYTETRAFLUOROETHYLENEVALVED CONDUITS WITH BULGING SINUSES. EUR J CARDIOTHORAC SURG 2020;58:1274¿80. DEVICE INFORMATION, PATIENT INFORMATION, AND CASE DETAILS WERE REQUESTED FROM THE CORRESPONDING AUTHOR; HOWEVER, TO DATE, NO ADDITIONAL INFORMATION HAS BEEN RECEIVED.

Description of Event or Problem · 0

THIS INFORMATION WAS RECEIVED THROUGH LITERATURE ARTICLE ¿LONG-TERM RESULTS OF LARGE-CALIBRE EXPANDED POLYTETRAFLUOROETHYLENE-VALVED CONDUITS WITH BULGING SINUSES¿ PUBLISHED IN THE EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 27 SEPTEMBER 2020. THE PURPOSE OF THIS STUDY WAS TO CLARIFY THE LONG-TERM OUTCOMES AND THE DURABILITY OF EPTFE-VALVED CONDUITS. BETWEEN JANUARY 2002 AND DECEMBER 2015, THERE WERE 502 PATIENTS WHO UNDERWENT RIGHT VENTRICULAR OUTFLOW TRACT RECONSTRUCTION IN 34 JAPANESE INSTITUTIONS USING EPTFE-VALVED CONDUITS. THE EPTFE TRICUSPID-VALVED CONDUIT IS A HANDMADE VALVED CONDUIT MANUFACTURED THROUGH TWO MAJOR PROCESSES. FIRST, BULGING SINUSES WERE MOLDED ON THE EPTFE GRAFT (STRETCH VASCULAR GRAFT, W.L. GORE & ASSOCIATES, INC., FLAGSTAFF, AZ, USA) AUTOMATICALLY USING A CUSTOM-MADE MACHINE. SECOND, THE FAN-SHAPED VALVES WERE CUT FROM THE 0.1-MM EPTFE MEMBRANE (PRECLUDE PERICARDIAL MEMBRANE, W.L. GORE & ASSOCIATES, INC.) AND SUTURED ON THE LUMEN SIDE OF THE GRAFT BEING TURNED INSIDE OUT. THE DIAMETER OF THE CONDUIT RANGES FROM 18 TO 24 MM, IN 2-MM INCREMENTS, CORRESPONDING TO THE SIZE OF THE EPTFE GRAFT. THE SIZE OF THE CONDUIT WAS SELECTED DEPENDING ON THE PHYSICAL CONSTITUTION AND THE ANATOMICAL FEATURES OF THE HEART. THE ARTICLE REPORTS THAT TWO PATIENTS DEVELOPED INFECTIVE ENDOCARDITIS OF THE CONDUIT AND RECEIVED INTRAVENOUS ANTIBIOTIC THERAPY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
811722 GORE-TEX® VASCULAR GRAFT PROSTHESIS, VASCULAR GRAFT DSY W. L. GORE & ASSOCIATES, INC.

Patients

Seq Age Sex Outcome Treatment
1 10 YR Male Required Intervention