FDA Adverse Event Malfunction Summary report: N

MICRODEBRIDER BLADES AND BURS

MDR report key: 14571442 · Received June 2, 2022

Report

Report Number
1045254-2022-00297
Event Type
Malfunction
Date Received
June 2, 2022
Date of Event
April 29, 2022
Report Date
September 12, 2022
Manufacturer
MEDTRONIC XOMED INC.
Product Code
EQJ
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AS
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Additional Manufacturer Narrative · 0

H3 : ANALYSIS OF BROKEN BUR FOUND THAT ALTHOUGH THERE WAS INITIALLY NO INFORMATION ON THE PART NUMBER, THE DEVICE CONFIGURATION WAS CONSISTENT WITH BEING PART OF THE MICRODEBRIDER HIGH-SPEED BUR PRODUCT FAMILY. THE SERVICE ORDER CONFIRMED THE FAULT AND NOTED THE STUCK BUR WAS REMOVED AND DIRT WAS BUILT UP INSIDE THE HOUSING AND AROUND COLLET NEEDED TO BE CLEANED. VISUALLY, THE INNER SHAFT BROKE 0.50 INCHES FROM THE DISTAL END OF THE INNER HUB. THE INNER HUB BUSHING WAS DISLODGED FROM ITS ASSEMBLY. BOTH THE INNER AND OUTER HUB BUSHINGS WERE ROUGH AND WORN. THE DISTAL TIP WAS LODGED INSIDE THE OUTER TUBE. THERE WERE STRIATIONS NEAR THE BREAK POINT. THERE WAS DEFORMATION IN THE DISTAL OUTSIDE DIAMETER OF THE INNER HUB WHICH WOULD HAVE RESULTED IN THE REPORTED EVENT. THE OUTSIDE DIAMETER OF THE INNER HUB SHOULD BE 0.330 ± 0.002 INCHES AND MEASURED 0.329 INCHES IN THE UNDAMAGED AREA AND UP TO 0.359 INCHES IN THE D EFORMED AREA WHICH WAS OUT OF SPECIFICATION. FUNCTIONAL TESTING COULD NOT BE PERFORMED DUE TO THE BROKEN STATE OF THE DEVICE. IN THE RETURNED CONDITION, THERE WAS AN OUT OF SPECIFICATION CONDITION THAT WAS RELATED TO THE COMPLAINT DUE TO PHYSICAL DAMAGE. H6 : CODES UPDATED. PREVIOUS FDM B17, FDR C20, FDC D14 AND IMG G04041 CODES NO LONGER APPLICABLE. MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

IT WAS REPORTED BY HCP THAT DURING USE THE DRILL BIT BROKE OFF AND STUCK. THERE WAS NO PATIENT IMPACT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
158934 MICRODEBRIDER BLADES AND BURS BUR, EAR, NOSE AND THROAT EQJ MEDTRONIC XOMED INC. XOM UNK MICDEBBUR

Patients

Seq Age Sex Outcome Treatment
1 Unknown