FDA Adverse Event Injury Summary report: N

COREVALVE TRANSCATHETER AORTIC VALVE

MDR report key: 14538496 · Received May 28, 2022

Report

Report Number
2025587-2022-01506
Event Type
Injury
Date Received
May 28, 2022
Date of Event
April 11, 2012
Report Date
May 28, 2022
Manufacturer
MEDTRONIC HEART VALVES DIVISION
Product Code
NPT
PMA / PMN Number
P130021
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

CITATION: GE´NE´REUX P.; ET AL. CLINICAL OUTCOMES AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT USING VALVE ACADEMIC RESEARCH CONSORTIUM DEFINITIONS. J AM COLL CARDIOL, 2012 JUNE; 59(25):2317¿2326. DOI: 10.1016/J.JACC.2012.02.022. PMID: 22503058. EPUB 2012 APR 11 EARLIEST DATE OF PUBLICATION USED FOR DATE OF EVENT. MEDTRONIC PRODUCTS REFERENCED: COREVALVE (PMA# P130021, PRODUCT CODE: NPT). EARLIEST APPROVED PRODUCT USED FOR PRODUCT CODE AND PMA#. NO UNIQUE DEVICE IDENTIFIER (SERIAL/LOT) NUMBERS WERE PROVIDED; WITHOUT THIS INFORMATION IT COULD NOT BE DETERMINED WHETHER THESE OBSERVATIONS HAVE BEEN PREVIOUSLY REPORTED. WITHOUT RETURN OF THE PRODUCT NO DEFINITIVE CONCLUSION CAN BE MADE REGARDING THE CLINICAL OBSERVATIONS. MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

MEDTRONIC RECEIVED INFORMATION VIA LITERATURE REGARDING THE RATES OF MAJOR OUTCOMES AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR). ALL DATA WERE COLLECTED FROM A LITERATURE META-ANALYSIS REVIEW BETWEEN JANUARY 1 THROUGH OCTOBER 12, 2011. THE META-ANALYSIS POPULATION INCLUDED 3519 PATIENTS WHO WERE PREDOMINANTLY FEMALE WITH A MEAN AGE OF 81.5 YEARS. MULTIPLE MANUFACTURER¿S DEVICES WERE IMPLANTED IN THE STUDY POPULATION. AMONG ALL PATIENTS, 1186 WERE IMPLANTED WITH MEDTRONIC COREVALVE BIOPROSTHETIC VALVES (UNIQUE DEVICE IDENTIFIER NUMBERS NOT PROVIDED). AMONG ALL PATIENTS, ALL-CAUSE 30-DAY MORTALITY WAS 7.8% WITH THE MAJORITY BEING CONSIDERED CARDIOVASCULAR DEATHS. THERE WAS NO FURTHER DESCRIPTION OF THE CAUSES OF DEATH. BASED ON THE AVAILABLE INFORMATION MEDTRONIC PRODUCT WAS NOT DIRECTLY ASSOCIATED WITH THE DEATHS. AMONG ALL PATIENTS, ADVERSE EVENTS INCLUDED: POST-PROCEDURAL MODERATE-SEVERE AORTIC REGURGITATION, POSITIONING DIFFICULTIES/INABILITY TO IMPLANT REQUIRING A NEED FOR MULTIPLE VALVE IMPLANTATIONS EITHER FROM REPEAT TAVRS OR SURGICAL INTERVENTION, VALVE EMBOLIZATION, MYOCARDIAL INFARCTION (MI), LIFE-THREATENING BLEEDING REQUIRING BLOOD TRANSFUSIONS, MAJOR VASCULAR COMPLICATIONS, STROKES, TRANSIENT ISCHEMIC ATTACKS (TIAS), NEED FOR PERMANENT PACEMAKER IMPLANTATION, CORONARY OBSTRUCTION, LEFT VENTRICULAR PERFORATION/RUPTURE, CARDIAC TAMPONADE, AORTIC ANNULUS RUPTURE, AORTIC DISSECTION, ENDOCARDITIS AND VALVE THROMBOSES. BASED ON THE AVAILABLE INFORMATION MEDTRONIC PRODUCT MAY HAVE BEEN ASSOCIATED WITH THE ADVERSE EVENTS. NO ADDITIONAL ADVERSE PATIENT EFFECTS OR PRODUCT PERFORMANCE ISSUES WERE REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1966045 COREVALVE TRANSCATHETER AORTIC VALVE AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIV NPT MEDTRONIC HEART VALVES DIVISION CRS

Patients

Seq Age Sex Outcome Treatment
1 82 YR Female Required Intervention| H| L