FDA Adverse Event Injury Summary report: N

FLEX 60 ARTICULATING

MDR report key: 14436921 · Received May 19, 2022

Report

Report Number
3005075853-2022-03266
Event Type
Injury
Date Received
May 19, 2022
Date of Event
February 2, 2021
Report Date
May 18, 2022
Manufacturer
ETHICON ENDO-SURGERY, LLC.
Product Code
GDW
UDI-DI
10705036001706
PMA / PMN Number
K081146
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

(B)(4). BATCH # UNKNOWN. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. AS PART OF OUR COMPANY QUALITY SYSTEM PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND DISTRIBUTED TO APPROVED SPECIFICATIONS. ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF THE POST-MARKET SURVEILLANCE. HOWEVER, IF THE PRODUCT OR PRODUCT ID NUMBERS ARE RECEIVED AT A LATER DATE, THE INVESTIGATION WILL BE UPDATED AS APPLICABLE. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE AUTHOR/SURGEON BELIEVE THAT THE ETHICON DEVICES MENTIONED IN THIS ARTICLE CAUSED/CONTRIBUTED TO THE REPORTED EVENTS IN THE ARTICLE?

Description of Event or Problem · 0

IT WAS REPORTED VIA JOURNAL ARTICLE; TITLE: NATURAL ORIFICE VERSUS CONVENTIONAL MINI-LAPAROTOMY FOR SPECIMEN EXTRACTION AFTER REDUCED-PORT LAPAROSCOPIC SURGERY FOR COLORECTAL CANCER: PROPENSITY SCORE-MATCHED COMPARATIVE STUDY AUTHORS: SHENG-CHI CHANG1,2 · TSUNG-HAN LEE2 · YI-CHANG CHEN1 · MEI-TSZ CHEN3 · HUNG-CHANG CHEN1 · TAO-WEI KE1 · YUAN-YAO TSAI1 · ABE FINGERHUT4,5 · WILLIAM TZU-LIANG CHEN1 CITATION: SURGICAL ENDOSCOPY (2022) 36:155¿166. HTTPS://DOI.ORG/10.1007/S00464-020-08250-8. THIS RETROSPECTIVE CASE MATCHED STUDY OF A PROSPECTIVELY COLLECTED DATA WAS TO INVESTIGATE THE IMPACT OF NATURAL ORIFICE SPECIMEN EXTRACTION (NOSE) COMPARED TO CONVENTIONAL SPECIMEN EXTRACTION IN PATIENTS WHO UNDERWENT REDUCED PORT LAPAROSCOPIC SURGERY (RPLS) FOR COLORECTAL CANCER. A TOTAL OF 119 PATIENTS WHO UNDERWENT ELECTIVE SIGMOID OR UPPER RECTAL CANCER RESECTION VIA RPLS BETWEEN APRIL 2013 AND JULY 2019 WERE INCLUDED. THE PATIENTS WERE DIVIDED INTO TWO GROUPS: RPLS WITH NOSE (RPLS-NOSE) IN 58 PATIENTS [33 WERE MALES; MEAN AGE OF 63.2 ± 11.9 YEARS; MEAN BMI OF 21 (36.2)] AND RPLS WITH CONVENTIONAL SPECIMEN EXTRACTION BY MINI-LAPAROTOMY (RPLS-CSE) IN 61 PATIENTS [25 WERE MALES; MEAN AGE OF 65.1 ± 12.2 YEARS; MEAN BMI OF 16 (26.2)]. AFTER A STANDARD LAPAROSCOPIC RESECTION TECHNIQUE, AND ISOLATION OF THE SPECIMEN, THE DISTAL RECTAL LUMEN WAS CLOSED WITH A NONABSORBABLE SUTURE (ETHIBOND EXCEL¿ POLYESTER SUTURE, ETHICON, USA). IN THE RPLS-NOSE GROUP, AN ARTICULATING LINEAR STAPLER (EC60A, BLUE CARTILAGE) WAS USED. IN THE RPLS-CSE GROUP, AN ARTICULATING LINEAR STAPLER (ECHELON FLEX 60 ENDOPATH STAPLER [EC60A] GREEN CARTILAGE; ETHICON, USA) AND A CIRCULAR STAPLER (CDH29A OR CDH33A; ETHICON, USA) WERE USED. REPORTED COMPLICATIONS INCLUDE ANASTOMOTIC SITE BLEEDING (N=1), IATROGENIC BLADDER INJURY (N=1), ANASTOMOTIC LEAKAGE (N=1), INTRAABDOMINAL ABSCESS (N=1), INTRAABDOMINAL INFECTION (N=2), PROLONG ILEUS (N=2) REQUIRING READMISSION IN ONE PATIENT, AND WOUND INFECTION (N=2) REQUIRING READMISSION IN ONE PATIENT. IN CONCLUSION, NOSE ENHANCES THE ADVANTAGES OF RPLS BY AVOIDING THE NEED FOR ABDOMINAL WALL SPECIMEN EXTRACTION IN PATIENTS WITH TUMOR DIAMETER = 5 CM. SURGICAL AND ONCOLOGIC SAFETY ARE COMPARABLE TO RPLS WITH CSE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1975986 FLEX 60 ARTICULATING STAPLE, IMPLANTABLE GDW ETHICON ENDO-SURGERY, LLC. EC60A 10705036001706

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention