FDA Adverse Event Malfunction Summary report: N

DREAMSTATION AUTO CPAP

MDR report key: 14354927 · Received May 11, 2022

Report

Report Number
2518422-2022-19933
Event Type
Malfunction
Date Received
May 11, 2022
Date of Event
April 18, 2022
Report Date
August 30, 2023
Manufacturer
RESPIRONICS,INC
Product Code
BZD
PMA / PMN Number
K131982
Removal / Correction Number
RES 88058
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE MANUFACTURER PREVIOUSLY REPORTED ON THIS DEVICE IN MDR 2518422-2021-03235-1. THIS REPORT WAS SUBMITTED AS A DUPLICATE REPORT OF THE PREVIOUSLY SUBMITTED REPORT.

Additional Manufacturer Narrative · 0

THE MANUFACTURER PREVIOUSLY REPORTED AN ALLEGATION OF AN ISSUE RELATED TO SOUND ABATEMENT FOAM. ADDITIONAL INFORMATION WAS RECEIVED AND SECTION B5 SHOULD BE REPORTED AS: THE MANUFACTURER WAS CONTACTED IN REFERENCE TO THE VOLUNTARY FIELD SAFETY NOTICE / RECALL NOTIFICATION RELATED TO THE SOUNDABATEMENT FOAM IN CERTAIN CPAP, BIPAP, AND MECHANICAL VENTILATOR DEVICES. THE MANUFACTURER RECEIVED INFORMATION ALLEGING ANISSUE RELATED TO A CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) DEVICE'S SOUND ABATEMENT FOAM. THE PATIENT ALLEGED CANCER AND HAD A LUNG REMOVED. THERE WAS NO MEDICAL INTERVENTION REQUIRED BY THEPATIENT. THE REPORTED EVENT OF CANCER AND HAD A LUNG REMOVED AND ITS REPORTED SEVERITY WAS REVIEWED BY THE MANUFACTURE'S CLINICAL EXPERT.THIS EVENT IS ASSESSED AS NOT RELATED TO THE DEVICE IN THIS CASE. BASED ON THE AVAILABLE INFORMATION, THE MANUFACTURE CONCLUDESNO FURTHER ACTION IS NECESSARY. THE DEVICE HAS NOT YET RETURNED TO THE MANUFACTURER FOR EVALUATION. THE PATIENT HAS SWAPPED OUT THE DEVICE AT THE DISTRIBUTOR AND AT THIS TIME, NO FURTHER INVESTIGATION CAN BE PERFORMED. IF ANY ADDITIONAL INFORMATION IS RECEIVED, A FOLLOW UP REPORT WILL BE FILED. SECTIONS B1, B2, HAS CHANGED RELATED TO THE COMPLAINT CHANGING FROM THE REPORTED ADVERSE EVENT TO A PRODUCT PROBLEM. SECTION H1 HAS CHANGED TO REFLECT A MALFUNCTION.

Description of Event or Problem · 0

THE MANUFACTURER RECEIVED INFORMATION ALLEGING A CPAP DEVICE'S SOUND ABATEMENT FOAM BECAME DEGRADED AND CAUSED CANCER. THE PATIENT DID REPORT TO RECEIVE MEDICAL INTERVENTION AND HAD A LUNG REMOVED. THE MANUFACTURER'S INVESTIGATION IS ONGOING. A FOLLOW-UP REPORT WILL BE SUBMITTED WHEN THE MANUFACTURER'S INVESTIGATION IS COMPLETE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1790633 DREAMSTATION AUTO CPAP VENTILATOR, NON-CONTINUOUS (RESPIRATOR) BZD RESPIRONICS,INC DSX500T11

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention| O