BARD® NASOGASTRIC SUMP TUBE WITH PREVENT® ANTI-REFLUX FILTER

MDR report key: 14315792 · Received May 7, 2022

Report

Report Number
1018233-2022-03363
Event Type
Malfunction
Date Received
May 7, 2022
Date of Event
February 11, 2022
Report Date
July 26, 2022
Manufacturer
C.R. BARD, INC. (COVINGTON) -1018233
Product Code
FEG
UDI-DI
00801741052323
PMA / PMN Number
K960176
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. THE DEVICE WAS NOT RETURNED.

Additional Manufacturer Narrative · 0

THE REPORTED EVENT WAS INCONCLUSIVE BECAUSE NO SAMPLE WAS RETURNED. A POTENTIAL ROOT CAUSE FOR THIS FAILURE COULD BE ¿INADEQUATE MATERIAL SELECTION DURING DESIGN PHASE ¿. IT IS UNKNOWN WHETHER THE DEVICE HAD MET RELEVANT SPECIFICATIONS. THE PRODUCT WAS USED FOR TREATMENT PURPOSES. IT WAS UNKNOWN WHETHER THE PRODUCT HAD CAUSED THE REPORTED FAILURE. THE DEVICE HISTORY RECORD WAS REVIEWED AND FOUND NOTHING THAT COULD HAVE CAUSED OR CONTRIBUTED TO THE REPORTED EVENT. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: ¿INDICATIONS FOR USE: BARD NASOGASTRIC SUMP TUBES ARE INTENDED TO BE USED FOR: ¿ DECOMPRESSION OF STOMACH BY SUCTION OR ASPIRATION OF GASTRIC CONTENTS. ¿ SHORT-TERM ADMINISTRATION OF TERM TUBE FEEDING, LAVAGE FL UID AND MEDICATIONS. CONTRAINDICATIONS: ¿ PATIENTS WITH KNOWN TAPE OR ADHESIVE ALLERGIES. WARNINGS 1. USE WITH CAUTION IN PATIENTS WITH A HISTORY OF HEAD TRAUMA, FACIAL TRAUMA, ESOPHAGEAL DISEASES AND PATIENTS WITH POTENTIAL FOR VOMITING. 2. DO NOT FORCE NASOGASTRIC TUBE DURING INSERTIONS; DAMAGE TO THE NASAL PASSAGE AND MUCOSA AND BLEEDING MAY OCCUR. 3. MEASURE INSERTION LENGTH CAREFULLY- EXCESSIVE INSERTION LENGTH OF TUBE INTO THE STOMACH MAY LEAD TO COILING AND/OR FORMATION OF TUBE-KNOT. 4. LUBRICATE THE TUBE GENEROUSLY WITH WATER SOLUBLE LUBRICANT PRIOR TO INSERTION. DO NOT USE PETROLEUM-BASED PRODUCTS AS THEY MAY BE HARMFUL TO THE RESPIRATORY TRACT. 5. REFL UX OF GASTRIC CONTENTS INTO THE BLUE VENT LUMEN INDICATES THAT THE SUCTION LUMEN IS OBSTRUCTED OR SUCTION IS TOO LOW. ROUTINELY CHECK FOR REFL UX IN THE BLUE VENT LUMEN AND CLEAR AS PER APPLICABLE DIRECTIONS. FAILURE TO CLEAR THE OBSTRUCTION OR CLEAR PREVENT® FILTER MAY CAUSE GAS AND FLUID BUILDUP IN STOMACH, ASPIRATION OF GASTRIC CONTENTS, ASPIRATION PNEUMONIA AND OTHER COMPLICATIONS. 6. DO NOT INJECT FL UID THROUGH THE PREVENT® FILTER AS THIS MAY RESULT IN BLOCKAGE AND LEAKAGE OF FI LTER. 7. MONITOR PATIENT FOR NASAL EROSION, SINUSITIS, ESOPHAGITIS, ESOPHAGOTRACHEAL FI STULA, GASTRIC EROSION AND PULMONARY & ORAL INFECTIONS. STATLOCK® NASOGASTRIC STABILIZATION DEVICE: AVOID CONTACT WITH ALCOHOL OR ACETONE; BOTH CAN WEAKEN BONDING OF COMPONENTS AND STATLOCK® STABILIZATION DEVICE PAD ADHERENCE. INSTRUCTIONS FOR NASOGASTRIC TUBE INSERTION 1. EXPLAIN THE PROCEDURE TO THE PATIENT. 2. CAREFULLY MEASURE TO FI ND DESIRED LENGTH OF THE TUBE USING THE NASOGASTRIC TUBE AS A MEASUREMENT AID. TO DETERMINE THE INSERTION LENGTH: MEASURE THE TUBE FROM THE TIP OF THE NOSE TO THE EARLOBE AND FROM THE EARLOBE TO THE TIP OF THE XIPHOID PROCESS. MARK THE LENGTH OF THE TUBE TO BE PASSED WITH A SMALL PIECE OF TAPE. 3. CHECK THE PATIENT¿S NOSTRILS FOR PATENCY; SELECT THE NOSTRIL WITH BEST PATENCY." CORRECTION : G H11:SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD. H3 OTHER TEXT : THE DEVICE WAS NOT RETURNED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE USER HAD INSERTED AN OROGASTRIC TUBE (OG) AS PER POLICY AND ONCE PLACED AND SECURED, THEY HAD FLUSHED IT WITH WATER. BUT LARGE AMOUNT OF WATER WAS LEAKING FROM ANTI REFLUX BLUE TUBING INSERTION SITE. THE TUBE WAS BACKING UP CAUSING LEAKAGE OF LARGE AMOUNTS OF GASTRIC CONTENTS DESPITE BEING CLAMPED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE USER HAD INSERTED AN OROGASTRIC TUBE (OG) AS PER POLICY AND ONCE PLACED AND SECURED, THEY HAD FLUSHED IT WITH WATER. BUT LARGE AMOUNT OF WATER WAS LEAKING FROM ANTI REFLUX BLUE TUBING INSERTION SITE. THE TUBE WAS BACKING UP CAUSING LEAKAGE OF LARGE AMOUNTS OF GASTRIC CONTENTS DESPITE BEING CLAMPED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1205896 BARD® NASOGASTRIC SUMP TUBE WITH PREVENT® ANTI-REFLUX FILTER NASOGASTRIC TUBE FEG C.R. BARD, INC. (COVINGTON) -1018233 0046160 NGDP3959 00801741052323

Patients

Seq Age Sex Outcome Treatment
1 Unknown Other