FDA Adverse Event Malfunction Summary report: N

YC-200 S PLUS

MDR report key: 14283301 · Received May 4, 2022

Report

Report Number
0002936921-2022-00003
Event Type
Malfunction
Date Received
May 4, 2022
Date of Event
April 12, 2022
Report Date
May 6, 2022
Manufacturer
NIDEK CO. LTD.
Product Code
HQF
UDI-DI
04987669101452
PMA / PMN Number
K203130
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

NIDEK INC. DETERMINED THAT THE CAUSE OF CUSTOMER REPORTED ISSUE PITTING LENS AND LOW POWER WAS INCONCLUSIVE. THE REPORTED ISSUE PITTING LENS AND LOW POWER WAS NOT DUPLICATED. NIDEK INC FIELD SERVICE ENGINEER (FSE) TESTED LASER FOCUS AND FOUND THAT THE TREATMENT AND AIMING BEAMS ARE PARFOCAL. TESTED THE LASER ENERGY AND FOUND IT WITHIN SPEC. 10MJ = 10MJ. LASER SHOT COUNT IS 10660. THE REPORTED UNIT PASSED FINAL INSPECTION PER INSPECTION DISTRIBUTION ACCEPTANCE RECORD (REF# IDAR-2021-0351), AND INSTALLATION AND IN-SERVICE TRAINING WAS PERFORMED PROPERLY PER INSTALLATION IN-SERVICE RECORD (REF# INS-2021-0161). THERE WAS NO SUPPORTING EVIDENCE TO POINT TO MACHINE, MAN, AND METHOD/PROCESS AND MATERIAL AS THE CAUSE OF THE REPORTED COMPLAINT ISSUE. AS A PRECAUTION, SPLIT ILLUMINATION TOWER WAS INSTALLED TO ALLOW MORE LIGHT WHEN VIEWING CAPSULE, AND RG-093-2 YC-200/ YC-200 S PLUS QUICK REFERENCE GUIDE WILL BE SENT OUT TO THE CUSTOMER TO REMIND CUSTOMER OF SAFETY INFORMATION IN YC-200 OPERATOR'S MANUAL TO MITIGATE AGAINST POTENTIAL OCCURRENCE OF PITTING LENSES. DEVICE EVALUATION IS COMPLETED AND FSE VERIFIED THAT THE SYSTEM IS OPERATIONAL.

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP MDR 0002936921-2022-00003 ADDS "DATE OF EVENT".

Description of Event or Problem · 0

ON (B)(6) 2022. NIDEK INC. CUSTOMER SERVICE REPRESENTATIVE RECEIVED AN EMAIL FROM THE CUSTOMER TO REPORT THAT ONE DOCTOR IS PITTING LENS, HE IS USING 1.2MJ AND A 275UM OFFSET, LOW ENERGY, LARGE OFFSET, NO ERROR DISPLAY ON UNIT. NO INJURY REPORTED. ON (B)(6) 2022. THE DEVICE EVALUATION WAS COMPLETED AT THE CUSTOMER SITE ON 04/13/2022. PER CUSTOMER SERVICE ORDER #CSO-2022-0278 BY NIDEK INC FIELD SERVICE ENGINEER. NIDEK INC. CONSIDERS PITTING LENS ISSUE A REPORTABLE EVENT AS IT IS AN UNDESIRABLE CONDITION AND HAS THE POTENTIAL TO CAUSE OR CONTRIBUTE TO A SERIOUS INJURY IF THE ISSUE WERE TO RECUR. TECHNICAL BACKGROUND: THE OPHTHALMIC YAG LASER SYSTEM YC-200 CONSISTS OF A SLIT LAMP AND THE YAG LASER AND IS INDICATED FOR THE PERFORMANCE OF POSTERIOR CAPSULOTOMY, PUPILLARY MEMBRANECTOMY, IRIDOTOMY (HOLE IN THE IRIS) AND SELECTIVE LASER TRABECULOPLASTY. THIS DEVICE USES PASSIVE Q-SWITCHING FOR LASER OSCILLATION. WITH PASSIVE Q-SWITCHING, THE DEVICE FIRST ACCUMULATES SUFFICIENT ENERGY WITHIN THE LASER CAVITY THEN EMITS LASER PULSES OF HIGH PEAK POWER FOR EXTREMELY SHORT DURATIONS BY USE OF THE Q-SWITCHED OPTICAL ELEMENT WHICH CHANGES BETWEEN TRANSPARENT AND OPAQUE ACCORDING TO THE ACCUMULATION OF ENERGY. YC-200 DEVICE IS EQUIPPED WITH YAG MODE FUNCTION ONLY. YC-200 S PLUS DEVICE IS EQUIPPED WITH YAG AND SLT MODE FUNCTIONS.

Description of Event or Problem · 0

PLEASE SEE INITIAL MDR SUBMITTED ON 05/03/2022.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
789435 YC-200 S PLUS YAG LASER HQF NIDEK CO. LTD. YC-200 04987669101452

Patients

Seq Age Sex Outcome Treatment
1 Unknown Other