FDA Adverse Event Injury Summary report: N

UNKN. POLARCUP SHELL NON-CEMENTED (TI-PLASMA OR TI/HA)

MDR report key: 14279669 · Received May 4, 2022

Report

Report Number
9613369-2022-00252
Event Type
Injury
Date Received
May 4, 2022
Date of Event
November 21, 2019
Report Date
July 19, 2022
Manufacturer
SMITH & NEPHEW ORTHOPAEDICS AG
Product Code
JDG
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INTERNAL COMPLAINT REFERENCE: (B)(4). CYPRES, A., FIQUET, A., GIRARDIN, P., FITCH, D., BAUCHU, P., BONNARD, O., & ROY, C. (2019). LONG-TERM OUTCOMES OF A DUAL-MOBILITY CUP AND CEMENTLESS TRIPLE-TAPER FEMORAL STEM COMBINATION IN TOTAL HIP REPLACEMENT: A MULTICENTER RETROSPECTIVE ANALYSIS. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 14(1), 1-6. DOI: HTTPS://DOI.ORG/10.1186/S13018-019-1436-Y.

Additional Manufacturer Narrative · 0

H3, H6: IN THE LITERATURE ARTICLE OF CYPRES ET AL. 2019 [1], IT WAS REPORTED THAT, 1 PATIENT SUFFERED FROM DELIRIUM TREMENS AFTER A PRIMARY TOTAL HIP REPLACEMENT SURGERY WITH THE POLAR SYSTEM. THE DEVICE, USED IN TREATMENT, WAS NOT RETURNED FOR INVESTIGATION AND THE PART AND BATCH NUMBER OF THE REPORTED COMPLAINT ARE NOT KNOWN. THEREFORE, IT IS NOT POSSIBLE TO INVESTIGATE WHETHER THE REPORTED DEVICE MET MANUFACTURING SPECIFICATION UPON RELEASE FOR DISTRIBUTION. THE SEVERITY AND THE FAILURE MODE ARE COVERED THROUGH OUR RISK MANAGEMENT. A THOROUGH MEDICAL INVESTIGATION COULD NOT BE PERFORMED DUE TO INSUFFICIENT INFORMATION. A REVIEW OF THE DEVICE LABELLING REVEALED THAT THE IFU (LIT. NO. 12.23 ED. 03/21) STATES KNOWN POSSIBLE RISK FACTORS AND SIDE EFFECTS IN COMBINATION WITH THE IMPLANTATION OF A HIP PROSTHESIS. BASED ON THE PERFORMED INVESTIGATIONS, THE FAILURE MODE AND THE RELATIONSHIP BETWEEN THE DEVICE AND THE REPORTED EVENT CANNOT BE CONFIRMED. DUE TO INSUFFICIENT INFORMATION, IT IS NOT POSSIBLE TO SPECULATE ABOUT FACTORS WHICH COULD HAVE CONTRIBUTED TO THE REPORTED EVENT AND IT IS NOT POSSIBLE TO PERFORM A REVIEW OF PAST CORRECTIVE ACTIONS. NO PROBABLE CAUSE CAN BE DETERMINED AND NO FURTHER ACTIONS WILL BE TAKEN TO THIS DATE. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS COMPLAINT WILL BE REASSESSED. SMITH AND NEPHEW WILL MONITOR THE DEVICES FOR FURTHER SIMILAR ISSUES.

Additional Manufacturer Narrative · 0

INTERNAL COMPLAINT REFERENCE NUMBER: (B)(4).

Description of Event or Problem · 0

IT WAS REPORTED THAT ON LITERATURE REVIEW "LONG-TERM OUTCOMES OF A DUAL-MOBILITY CUP AND CEMENTLESS TRIPLE-TAPER FEMORAL STEM COMBINATION IN TOTAL HIP REPLACEMENT: A MULTICENTER RETROSPECTIVE ANALYSIS", 1 PATIENT SUFFERED FROM DELIRIUM TREMENS AFTER A PRIMARY THR WITH THE POLAR SYSTEM. IT WAS NOT REPORTED HOW THE ADVERSE EVENT WAS RESOLVED. THE OUTCOME OF THE PATIENT IS UNKNOWN. NO FURTHER INFORMATION IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1442911 UNKN. POLARCUP SHELL NON-CEMENTED (TI-PLASMA OR TI/HA) PROSTHESIS, HIP, FEMORAL COMPONENT, CEMENTED, METAL JDG SMITH & NEPHEW ORTHOPAEDICS AG UNK

Patients

Seq Age Sex Outcome Treatment
1 Unknown Other