BD DISCARDIT¿ II SYRINGE 2 ML WITH 25X1¿
Report
- Report Number
- 2243072-2022-00469
- Event Type
- Malfunction
- Date Received
- April 15, 2022
- Date of Event
- March 22, 2022
- Report Date
- April 6, 2022
- Manufacturer
- BECTON DICKINSON
- Product Code
- FMF
- PMA / PMN Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
THE MANUFACTURING LOCATION FOR THIS PRODUCT IS (B)(4). THIS SITE IS AN OEM MANUFACTURING SITE. THEREFORE, BD CORPORATE HEADQUARTERS IN (B)(4) HAS BEEN LISTED AND THE (B)(4) FDA REGISTRATION NUMBER HAS BEEN USED FOR THE MANUFACTURE REPORT NUMBER. INVESTIGATION SUMMARY: THE PHOTOS WERE RECEIVED BY BD FOR EVALUATION. A QUALITY ENGINEER WAS ABLE TO REVIEW THE PHOTOS OF A DISCARDIT 2ML FROM LOT # 0214098 REGARDING ITEM # 301866 WITH THE REPORTED ISSUE OF DAMAGED SYRINGE. THERE ARE NO SAMPLES AND 33 PHOTOGRAPHS RECEIVED FROM THE CUSTOMER ALONG WITH THE REPORTED COMPLAINT OF MULTIPLE DEFECTS. THE INVESTIGATING TEAM HAS ALSO USED THE RETENTION SAMPLES FROM LOT # 0214098, 0242834, 1175953, 1203233 REGARDING ITEM # 301866 FOR INVESTIGATING THE REPORTED DEFECT. THE INVESTIGATION AND SIMULATION WERE CARRIED OUT ON TEN RETENTION SAMPLES WHERE THE INVESTIGATING TEAM HAS VISUALLY TESTED THE SAMPLES AND NONE OF THE MULTIPLE DEFECTS WERE FOUND. BASED ON THE PHOTOGRAPHS, THE DEFECTS ARE CONFIRMED. ALL THE FOUR LOTS WERE MANUFACTURED BETWEEN 2020 AND 2021. THERE ARE MULTIPLE ACTIONS TAKEN FROM 2021 ONWARDS UNDER THE QUALITY IMPROVEMENT PROGRAM WHICH IS CURRENTLY ONGOING. DAMAGED SYRINGE- TIP OF SYRINGE IS DAMAGED IF PRESSURE TO BLOCK THE TIP IS HIGH AT CHALLENGE TEST STATION. REFRESHER TRAINING TO BE PROVIDED TO OPERATORS TO ENSURE THAT SMOOTH MOVEMENT OF CYLINDER AT CHALLENGE TEST STATION. TARGET DATE- (B)(6) 2022 COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. BASED ON THE ABOVE, NO ADDITIONAL INVESTIGATION AND NO CAPA IS REQUIRED AT THIS TIME. BASED ON THE PHOTOGRAPH DEFECT IS CONFIRMED. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. IF SAMPLES ARE RECEIVED IN THE FUTURE THE COMPLAINT WILL BE REOPENED FOR FURTHER INVESTIGATION.
IT WAS REPORTED WHILE USING BD DISCARDIT¿ II SYRINGE 2 ML WITH 25X1¿ A THE DEVICE WAS FOUND TO BE DAMAGED. THIS OCCURRED 9 TIMES. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: SYRINGES: DAMAGE SYRINGE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 138448 | BD DISCARDIT¿ II SYRINGE 2 ML WITH 25X1¿ | PISTON SYRINGE | FMF | BECTON DICKINSON | 0214098 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |