INPEN MMT-105NNGYNA NOVO NORDISK GRAY
Report
- Report Number
- 3012822846-2022-00620
- Event Type
- Injury
- Date Received
- April 13, 2022
- Date of Event
- April 8, 2022
- Report Date
- May 5, 2022
- Manufacturer
- COMPANION MEDICAL INC
- Product Code
- FMF
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SD, US
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
CURRENTLY IT IS UNKNOWN WHETHER OR NOT THE DEVICE MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT AS NO PRODUCT HAS BEEN RETURNED. THE DEVICE WILL BE RETURNED FOR ANALYSIS AND FURTHER INFORMATION WILL FOLLOW ONCE THE ANALYSIS HAS BEEN COMPLETED. NO CONCLUSION CAN BE DRAWN AT THIS TIME.
SERIAL NUMBER: (B)(6), SOFTWARE VERSION: 3.8.5, COLOR: GREY, BATTERY LIFE REMAINING: 10 MONTHS. PER VISUAL INSPECTION: CAP DOES NOT FIT SECURELY TO INPEN. NO PHYSICAL DAMAGE TO CARTRIDGE HOLDER WAS NOTED. CUSTOMER REPORTS: INPEN MAY NOT BE WORKING. UNIT PAIRED SUCCESSFULLY TO COMMERCIAL APP. INPEN RECEIVED WITH LEADSCREW 1/4 OF THE TRAVEL. RE-WOUND SCREW. NO DRAG WAS OBSERVED. THE SCREW WAS NOT BENT, ADVANCED WHEN DOSAGE KNOB WAS PRESSED, DIALING A DOSAGE AND RETRACTED APPROPRIATELY. NO RESISTANCE WAS OBSERVED, WHEN DOSING WITHOUT A CARTRIDGE INSTALLED. THE SCREW ADVANCED EVERY TIME 30.0U WAS DIALED AND DOSED UNTIL THE SCREW REACHED MAX EXTENSION. IN CONCLUSION: INPEN CAP DOES NOT FIT SECURELY ONTO CARTRIDGE HOLDER, DUE TO SMALL SNAP ARM BEING CRACKED/BROKEN. INPEN RECEIVED, WORKING AS DESIGN. NO MALFUNCTIONS NOTED, DURING TESTING THAT COULD AFFECT INSULIN DELIVERY. THE CUSTOMER COMPLAINT OF INPEN NOT WORKING WAS NOT CONFIRMED. MEDTRONIC, INC. (MEDTRONIC) IS SUBMITTING THIS REPORT TO COMPLY WITH 21 C.F.R. PART 803, THE MEDICAL DEVICE REPORTING REGULATION. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION IN THE TIME ALLOTTED AND HAS PROVIDED AS MUCH INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY "DEFECTS" OR HAS "MALFUNCTIONED". THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA, TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REPORTING PURSUANT TO PART 803. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE IT BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT.
THE CUSTOMER REPORTED VIA PHONE CALL THAT THEY EXPERIENCED HIGH BLOOD GLUCOSE. THE CUSTOMER¿S BLOOD GLUCOSE LEVEL WAS 466 MG/DL AT THE TIME OF INCIDENT. CUSTOMER STATED THAT BUTTONS WERE FEELING DIFFERENT. TROUBLESHOOTING WAS DECLINED. NO FURTHER PATIENT COMPLICATIONS WERE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2563552 | INPEN MMT-105NNGYNA NOVO NORDISK GRAY | SYRINGE, PISTON | FMF | COMPANION MEDICAL INC | MMT-105NNGYNA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 56 YR | Female | Other |