FDA Adverse Event Malfunction Summary report: N

MAGEC SPINAL BRACING AND DISTRACTION SYSTEM

MDR report key: 14104387 · Received April 13, 2022

Report

Report Number
3006179046-2022-00168
Event Type
Malfunction
Date Received
April 13, 2022
Report Date
June 27, 2022
Manufacturer
NUVASIVE SPECIALIZED ORTHOPEDICS, INC.
Product Code
PGN
UDI-DI
00887517834041
PMA / PMN Number
K171791
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE HAS NOT BEEN RETURNED FOR EVALUATION. THE ROOT CAUSE IS UNABLE TO BE DETERMINED AT THIS TIME. IF ANY ADDITIONAL INFORMATION IS PROVIDED, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.

Additional Manufacturer Narrative · 0

ADDITIONAL DATA: B5, D4, G3, G6, H2, G6, H10.

Additional Manufacturer Narrative · 0

THE REPORTER PROVIDED THE MODEL AND LOT NUMBER OF TWO MAGEC RODS, BUT IT IS UNKNOWN WHICH OF THE TWO HAS THE REPORTED FAILURE TO DISTRACT. THE TWO RODS WERE REPORTED AS FOLLOWS: MC2-5090S LOT NUMBER 9052408 MC2-5090R LOT NUMBER 8122112.

Additional Manufacturer Narrative · 0

CORRECTED DATA: D4, G4 ADDITIONAL DATA: B5, D9, G3, G6, H2, H3, H6, H10. COMPLAINT 1 OF 2. VISUAL INSPECTION OF THE RETURNED MAGEC ROD REVEALED THAT THE ROD WAS PARTIALLY DISTRACTED WITH SOME WEAR/SCORE MARKS CONSISTENT WITH EXPECTED MARKINGS DUE TO INCREMENTAL DISTRACTION. THE WEAR/SCORE MARKS OBSERVED ON THE DISTRACTION ROD WOULD INDICATE THE DISTRACTION ROD WAS EXTENDED APPROXIMATELY 7.00 MM FROM ITS INITIAL POSITION. X-RAY IMAGES OF THE INTERNAL COMPONENTS SHOWED NO DAMAGE AND REVEALED THE ROD WAS PARTIALLY DISTRACTED. THE LENGTH OF THE ROD WAS MEASURED AT 267.10 MM. THE ROD WAS FUNCTIONALLY TESTED AND WAS ABLE TO DISTRACT AND RETRACTOR WITH THE MANUAL DISTRACTOR AS WELL AS THE EXTERNAL REMOTE CONTROLLER (ERC). THE MINIMAL AND MAXIMUM LENGTHS WERE MEASURED AT 261.84 MM AND 308.90 MM RESPECTIVELY, GIVING A TOTAL STROKE MEASUREMENT OF 47.06 MM, WHICH MEETS THE SPECIFICATION. THE REPORTED FAILURE MODE WAS UNABLE TO BE CONFIRMED, AS THE ROD WAS FULLY FUNCTIONAL AND MET ACCEPTANCE TEST SPECIFICATIONS. REVIEW OF THE DEVICE HISTORY RECORDS REVEALED NO DISCREPANCIES RELATED TO THIS COMPLAINT. THE ROD WAS MANUFACTURED IN ACCORDANCE WITH THE SPECIFIED REQUIREMENTS AND MET ALL OF THE REQUIRED QUALITY INSPECTIONS.

Description of Event or Problem · 0

INFORMATION WAS RECEIVED THAT THE ROD WOULD NOT DISTRACT. NO PATIENT ADVERSE EVENT WAS REPORTED.

Description of Event or Problem · 0

ADDITIONAL INFORMATION WAS RECEIVED.

Description of Event or Problem · 0

ADDITIONAL INFORMATION WAS RECEIVED.

Description of Event or Problem · 0

NO ADDITIONAL INFORMATION WAS PROVIDED.