HEATED BREATHING TUBE AND CHAMBER KIT
Report
- Report Number
- 9611451-2022-00341
- Event Type
- Malfunction
- Date Received
- April 5, 2022
- Date of Event
- March 3, 2022
- Report Date
- March 9, 2022
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LTD
- Product Code
- BTT
- UDI-DI
- 09420012433794
- PMA / PMN Number
- K162553
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- BIOMEDICAL ENGINEER
- Health Professional
- Yes
Narratives
(B)(4). WE ARE CURRENTLY IN THE PROCESS OF RETRIEVING THE COMPLAINT 900PT561 AIRVO 2 HEATED BREATHING TUBE FOR EVALUATION. WE WILL PROVIDE A FOLLOW UP REPORT UPON COMPLETION OF OUR INVESTIGATION.
(B)(4). THE F&P 900PT562 AIRVO TUBE AND CHAMBER KIT WITH NEBULIZER ADAPTER IS NOT CURRENTLY AVAILABLE FOR SALE IN THE UNITED STATES OF AMERICA (USA) BUT IT IS SIMILAR TO A PRODUCT WHICH IS SOLD IN THE USA. THE 510(K) FOR THAT PRODUCT, THE 900PT561 HEATED BREATHING TUBE AND CHAMBER KIT, IS K162553. THE HEATED BREATHING TUBE (HBT) IS A COMPONENT DESIGNED FOR USE WITH THE AIRVO 2 HUMIDIFIER (AIRVO 2), FOR THE DELIVERY OF HUMIDIFIED RESPIRATORY GASES TO PATIENTS, INCLUDING THOSE WHO ARE RECEIVING NASAL HIGH FLOW (NHF) THERAPY. NHF THERAPY IS INTENDED FOR USE WITH SPONTANEOUSLY BREATHING PATIENTS WHO WOULD BENEFIT FROM RECEIVING HIGH FLOW WARMED AND HUMIDIFIED RESPIRATORY GASES. THE AIRVO 2 DEVICE SHOULD NOT BE USED FOR LIFE SUPPORT PURPOSES, AND APPROPRIATE PATIENT MONITORING MUST BE USED AT ALL TIMES. THE HBT AS PART OF THE AIRVO 2 SYSTEM CONTAINS A HEATER WIRE ENCAPSULATED IN PLASTIC WHICH ENSURES OPTIMAL TEMPERATURE AND HUMIDIFICATION LEVELS ARE DELIVERED TO THE PATIENT INTERFACE WHILE MINIMIZING THE AMOUNT OF CONDENSATE IN THE TUBE. METHOD: THE SUBJECT HBT AS PART OF THE 900PT562 AIRVO HEATED BREATHING TUBE AND CHAMBER KIT WITH NEBULIZER ADAPTER WAS RETURNED TO FISHER & PAYKEL HEALTHCARE (F&P) FOR INVESTIGATION WHERE IT WAS VISUALLY INSPECTED. FURTHER INFORMATION REGARDING THE REPORTED EVENT INCLUDING THE DEVICE SET-UP WAS REQUESTED FROM THE HEALTHCARE FACILITY, HOWEVER THE HEALTHCARE FACILITY WAS ONLY ABLE TO PROVIDE LIMITED INFORMATION. OUR INVESTIGATION IS BASED ON THE EVALUATION OF THE SUBJECT HBT, THE INFORMATION PROVIDED BY THE HEALTHCARE FACILITY AND F&P'S KNOWLEDGE OF THE PRODUCT. RESULTS: THE VISUAL INSPECTION REVEALED THAT THE RETURNED HBT WAS IN TWO PIECES. THE MIDDLE OF THE HBT, APPROXIMATELY 20CM IN LENGTH, WAS MELTED AND OTHER PARTS WERE OBSERVED TO HAVE SOFTENED AND STARTED TO UNRAVEL. THE HEALTHCARE FACILITY REPORTED THAT THE CIRCUIT CLIP WAS NOT USED TO SECURE THE HBT IN PLACE. THE HEALTHCARE FACILITY CONFIRMED THAT THE SUBJECT DEVICE HAD BEEN IN USE FOR 3 DAYS PRIOR TO EVENT AND DID NOT REPORT ANY ISSUES WITH THE DEVICE. CONCLUSION: WE ARE UNABLE TO DETERMINE THE CAUSE OF THE REPORTED EVENT. HOWEVER, DAMAGE TO THE HBT MAY BE CAUSED BY FACTORS SUCH AS INCORRECT SET-UP OR COVERING IT WITH A MATERIAL OR OBJECT FOR A PROLONGED PERIOD. THE NATURE OF THE DAMAGE OBSERVED IN THE RETURNED HBT SUGGESTS THAT THE HBT WAS COVERED BY A MATERIAL OR OBJECT FOR A PROLONGED PERIOD OF TIME. PARTS OF THE HBT WERE ALSO OBSERVED TO HAVE SOFTENED AND STARTED TO UNRAVEL, WHICH IS CONSISTENT WITH TUBE BEING COVERED AND THEN BEING SUBJECTED TO TENSION OR EXCESSIVE FORCE. THE 900PT562 USER INSTRUCTIONS SHOW IN PICTORIAL FORMAT THE CORRECT PLACEMENT OF THE DEVICE AND INCLUDES THE FOLLOWING INFORMATION: "CONNECT BREATHING TUBE CLIP TO PATIENT CLOTHING OR BEDDING." "NEVER OPERATE THE UNIT IF THE BREATHING TUBE HAS BEEN DAMAGED WITH HOLES, TEARS OR KINKS." "DO NOT BLOCK THE FLOW OF AIR THROUGH THE UNIT AND BREATHING TUBE." "DO NOT ADD HEAT TO ANY PART OF THE BREATHING TUBE E.G., COVERING WITH A BLANKET, OR HEATING IT IN AN INCUBATOR OR OVERHEAD HEATER FOR A NEONATE, AS THIS COULD RESULT IN SERIOUS INJURY." ALL HBTS AS PART OF THE 900PT562 AIRVO TUBE AND CHAMBER KITS WITH NEBULIZER ADAPTER ARE VISUALLY INSPECTED AND UNDERGO FUNCTIONAL TESTS, INCLUDING SOAK AND TEMPERATURE, AND HEATER WIRE RESISTANCE. THE HEATED BREATHING TUBES ARE 100% VISUALLY INSPECTED USING A CAMERA SYSTEM. THE HBTS ARE ALSO TESTED FOR RESISTANCE, CONTINUITY, POLARITY AND PITCH DURING PRODUCTION. ADDITIONALLY, A FUNCTIONAL TEST IS CONDUCTED UNDER LOAD. THE HBT WOULD HAVE MET THE REQUIRED SPECIFICATIONS AT THE TIME OF PRODUCTION. THE AIRVO 2 SYSTEM IS DESIGNED TO COMPLY WITH THE ELECTRICAL SAFETY STANDARD IEC 60601-1: 2005+A1:2012. THE CASE IS COMPOSED OF A FLAME RETARDANT MATERIAL. THE SURFACE TEMPERATURE OF THE HBT, WHEN USED IN ACCORDANCE WITH USER INSTRUCTIONS, IS DESIGNED TO BE WITHIN THE LIMITS SPECIFIED BY ISO 8185 WITH REGARD TO HOT TUBE SURFACE TEMPERATURE NOT EXCEEDING 44° CELSIUS. IT IS AN INHERENT RISK OF HBTS, THAT ADDITIONAL HEAT (ABOVE AMBIENT LEVELS) ADDED TO ANY PART OF THE TUBE VIA AN EXTERNAL SOURCE OR BEING COVERED WITH MATERIAL, MAY LEAD TO THE TUBING BECOMING DAMAGED. TO ADDRESS THIS INHERENT RISK AND AS IS REQUIRED UNDER ISO 80601, THE USER INSTRUCTIONS FOR THE 900PT562 CONTAINS THE WARNING "DO NOT ADD HEAT TO ANY PART OF THE BREATHING TUBE E.G. COVERING WITH A BLANKET, OR HEATING IT IN AN INCUBATOR OR OVERHEAD HEATER FOR A NEONATE, AS THIS COULD RESULT IN SERIOUS INJURY." ADDITIONAL "DO NOT COVER" TAGS ARE ALSO ATTACHED TO ALL HBTS TO ALERT THE USER THAT THE HBT SHOULD NOT BE COVERED. THERE ARE MANY SAFETY FEATURES INCORPORATED INTO THE AIRVO 2 SYSTEM TO PREVENT OVERHEATING AND FIRE. THESE INCLUDE: THE HEATER WIRES IN THE HBT ARE COMPLETELY INSULATED FROM THE GAS PATH. THE PCB AT THE [PATIENT] END OF THE HBT IS OVER MOULDED WITH THE THERMOPLASTIC POLYMER POLYPROPYLENE, ENSURING IT IS EXCLUDED FROM THE GAS PATH. THE AIRVO 2 DEVICE CONTAINS TECHNOLOGY WHICH DETECTS ANY SHORT CIRCUIT IN THE SYSTEM. THIS FUNCTIONALITY IS CHECKED BY THE CONTROL SYSTEM WHEN THE AIRVO 2 IS POWERING UP BEFORE EACH USE. AN 'OVER-TEMPERATURE' SENSOR WILL AUTOMATICALLY CUT POWER TO THE MOTOR, HEATER PLATE AND HEATER WIRE IF IT DETECTS ANY OVERHEATING AT THE CHAMBER OR THE PATIENT END OF THE HBT. THE AIRVO 2 DEVICE IS CONTINUOUSLY CHECKS POWER IN THE HBT AND DISABLES THE HEATER WIRE IF THE MEASURED POWER IS TOO HIGH.
A HEALTHCARE FACILITY IN (B)(6) REPORTED VIA A FISHER & PAYKEL HEALTHCARE (F&P) FIELD REPRESENTATIVE THAT THE HEATED BREATHING TUBE AS PART OF A 900PT561 AIRVO 2 HEATED BREATHING TUBE AND CHAMBER KIT MELTED DURING USE. THERE WERE NO PATIENT CONSEQUENCES.
A HEALTHCARE FACILITY IN GERMANY REPORTED VIA A FISHER & PAYKEL HEALTHCARE (F&P) FIELD REPRESENTATIVE THAT APPROXIMATELY 20CM OF THE HEATED BREATHING TUBE AS PART OF A 900PT561 AIRVO 2 HEATED BREATHING TUBE AND CHAMBER KIT MELTED DURING USE. THERE WERE NO PATIENT CONSEQUENCES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1131848 | HEATED BREATHING TUBE AND CHAMBER KIT | BTT | BTT | FISHER & PAYKEL HEALTHCARE LTD | 900PT561 | 2101463740 | 09420012433794 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | F&P OPT944 OPTIFLOW + ADULT NASAL CANNULA| F&P OPT944 OPTIFLOW + ADULT NASAL CANNULA| F&P PT101 AIRVO 2 HUMIDIFIER| F&P PT101 AIRVO 2 HUMIDIFIER |