TECNIS IOL
Report
- Report Number
- 3012236936-2022-00865
- Event Type
- Injury
- Date Received
- April 1, 2022
- Report Date
- April 1, 2022
- Manufacturer
- AMO PUERTO RICO MFG. INC.
- Product Code
- MJP
- PMA / PMN Number
- P980040
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
AGE/DATE OF BIRTH: AGE RANGE BETWEEN 64 ± 11 (MEAN ± STANDARD DEVIATION {SD}). UNKNOWN AS INFORMATION WAS NOT PROVIDED. DATE OF EVENT: DATE ARTICLE ACCEPTED IS JULY 5, 2021. CATALOG NUMBER: A COMPLETE CATALOG NUMBER IS UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. SERIAL NUMBER: UNKNOWN, AS INFORMATION WAS NOT PROVIDED. EXPIRATION DATE: UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. UDI NUMBER: A COMPLETE UDI NUMBER IS UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. IMPLANT DATE: UNKNOWN, AS INFORMATION WAS NOT PROVIDED. EXPLANT DATE: NOT APPLICABLE, AS LENS REMAINS IMPLANTED. THE DEVICE WAS NOT RETURNED FOR ANALYSIS. THE SERIAL NUMBER FOR THIS DEVICE IS NOT AVAILABLE; THEREFORE, NO FURTHER INVESTIGATION CAN BE PERFORMED. IF THERE IS ANY FURTHER RELEVANT INFORMATION RECEIVED, A SUPPLEMENTAL MEDWATCH WILL BE FILED. DEVICE MANUFACTURE DATE: UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. CITATION: BRAR, S., RATHOD, D.P., NIKHIL, R.P., GANESH, S. (2021). CLINICAL OUTCOMES, PREDICTABILITY AND ROTATIONAL STABILITY FOLLOWING IMPLANTATION OF EYECRYL TORIC VERSUS TECNIS TORIC INTRAOCULAR LENSES¿A COMPARATIVE STUDY. INT OPHTHALMOL. 41(1), PP. 3769-3780. . ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.
THE FOLLOWING ARTICLE WAS RECEIVED BASED ON A LITERATURE REVIEW: ARTICLE: CLINICAL OUTCOMES, PREDICTABILITY AND ROTATIONAL STABILITY FOLLOWING IMPLANTATION OF EYECRYL TORIC VERSUS TECNIS TORIC INTRAOCULAR LENSES¿A COMPARATIVE STUDY A RETROSPECTIVE STUDY WAS DONE TO COMPARE THE VISUAL OUTCOMES, PREDICTABILITY AND ROTATIONAL STABILITY FOLLOWING IMPLANTATION OF EYECRYL TORIC VERSUS TECNIS TORIC INTRAOCULAR LENSES. A TOTAL OF 100 EYES FROM 78 PATIENTS WERE INCLUDED IN THIS STUDY WHO UNDERWENT PHACOEMULSIFICATION USING THE FOLLOWING IOLS: EYECRYL TORIC IOL (N=50 EYES), AND TECNIS TORIC IOL (N=50 EYES). AT 1ST WEEK AFTER SURGERY, THERE WAS A SIGNIFICANT ROTATION OF THE TORIC IOL (>10 DEGREES) IN TECNIS TORIC GROUP REQUIRING IOL RE-POSITIONING (N=2 EYES). THESE IOLS WERE RE-POSITIONED ON THE SAME DAY, AFTER WHICH THEY REMAINED STABLE AT THE SUBSEQUENT VISITS. AT 6 MONTHS POST OP, TECNIS TORIC GROUP HAD POST-OP ROTATION BETWEEN 11 AND 15 DEGREES (N=3 EYES). THESE WERE NOT RE-ALIGNED AND WERE LEFT AS IT IS. THE MEAN POST-OP ROTATION WAS 4.44 ± 2.77 DEGREES IN TECNIS TORIC GROUPS. THIS REPORT IS FOR THE INTRAOCULAR LENS, MODEL ZCT700. SEPARATE REPORTS ARE BEING SUBMITTED FOR THE OTHER TORIC MODELS ZCT-100, 150, 225, 300, 375, 450, 525, 600, AND 800. IT IS NOT CLEAR WHICH TORIC MODEL OCCURRED IN THE EYES WITH THE COMPLICATION. A COPY OF THE ARTICLE IS PROVIDED WITH THIS REPORT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1329779 | TECNIS IOL | LENS, INTRAOCULAR, TORIC OPTICS | MJP | AMO PUERTO RICO MFG. INC. | ZCT700 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | Required Intervention |