FDA Adverse Event Injury Summary report: N

EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE

MDR report key: 13972907 · Received April 1, 2022

Report

Report Number
2015691-2022-04740
Event Type
Injury
Date Received
April 1, 2022
Date of Event
July 8, 2020
Report Date
April 1, 2022
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
PMA / PMN Number
P140031
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

CITATION: KUYAMA, NAOTO, ET AL. ''LEFT CORONARY OSTIAL STENOSIS DEVELOPING 15 MONTHS AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT WITH BALLOON-EXPANDABLE VALVE.'' JOURNAL OF CARDIOLOGY CASES 25.2 (2022): 115-118. PER THE INSTRUCTIONS FOR USE (IFU), CORONARY FLOW OBSTRUCTION IS A KNOWN POTENTIAL ADVERSE EVENT ASSOCIATED WITH THE TAVR PROCEDURE. THE IFU CAUTIONS THAT SAFETY AND EFFECTIVENESS HAVE NOT BEEN ESTABLISHED FOR PATIENTS WITH BULKY CALCIFIED AORTIC VALVE LEAFLETS IN CLOSE PROXIMITY TO CORONARY OSTIA. IN ADDITION, IT WARNS THAT CAUTION SHOULD BE EXERCISED IN IMPLANTING A BIOPROSTHESIS IN PATIENTS WITH CLINICALLY SIGNIFICANT CORONARY ARTERY DISEASE. CORONARY OBSTRUCTION CAN RESULT IN MYOCARDIAL ISCHEMIA OR INFARCTION DUE TO OBSTRUCTION OF THE CORONARY BLOOD FLOW AND MAY REQUIRE INTERVENTION (E.G. PERCUTANEOUS CORONARY INTERVENTION (PCI)). MULTIPLE PATIENT FACTORS COULD PUT THE PATIENT AT RISK FOR CORONARY FLOW OBSTRUCTION DURING THE THV PROCEDURE, INCLUDING SIGNIFICANT UNDERLYING CORONARY ARTERY DISEASE AND BULKY CALCIFICATION OF THE NATIVE LEAFLETS AND ROOT. DISPLACEMENT OF CALCIUM DEPOSITS WITH EMBOLIZATION OF DEBRIS INTO ONE OF THE ARTERIES, OR AORTIC DISSECTION WITH CONTINUITY OF THE RUPTURE INTO THE INTIMA OF ONE OF THE CORONARY OSTIA, CAN RESULT IN THIS COMPLICATION. ADDITIONALLY, MINIMAL DISTANCE BETWEEN THE NATIVE ANNULUS AND THE CORONARY OSTIA, BULKY CALCIFICATION, LONG NATIVE LEAFLETS, AND OBLITERATED CORONARY SINUSES. PROCEDURAL FACTORS SUCH AS TORN NATIVE LEAFLET DURING BAV, PLAQUE SHIFT, DEPLOYMENT OF THE BIOPROSTHETIC HEART VALVE TOO AORTIC, AND SIGNIFICANT VALVE OVER SIZING COULD ALSO CONTRIBUTE TO THIS COMPLICATION. THE EDWARDS THV TRAINING MANUALS ADVISE THE OPERATOR ON PRE-PROCEDURE ASSESSMENT OF THE AORTIC VALVE, ROOT, AND CORONARY ANATOMY. PHYSICIANS ARE EXTENSIVELY TRAINED BY EDWARDS BEFORE THEY ARE QUALIFIED TO USE THE TRANSCATHETER HEART VALVE (THV). TRAINING INCLUDES PATIENT SCREENING, DEVICE PREPARATION, APPROACH, DEPLOYMENT, IMAGING, PROCEDURE-SPECIFIC TRAINING MANUALS, AND PROCTORED PROCEDURES. THE PHYSICIAN IS INSTRUCTED TO EVALUATE THIS RISK EARLY IN THE PATIENT SCREENING PROCESS IN ALL PATIENTS THE FOLLOWING FACTORS SHOULD BE CONSIDERED: DEGREE OF CALCIFICATION ON LEAFLETS, ANNULUS TO CORONARY OSTIA DISTANCE, LENGTH OF THE VALVE LEAFLET, WIDTH OF THE VALSALVA SINUSES, MOVEMENT OF THE LEAFLETS DURING BAV, PATENCY OF CORONARIES DURING BAV, AND EXPANDED HEIGHT OF THE INTENDED THV. THE TRAINING MANUALS ALSO PROVIDE THE FOLLOWING TIPS FOR DETECTING RISK FOR LEFT MAIN OCCLUSION: (1) AORTOGRAM OR TEE BEFORE THV IMPLANTATION TO REVEAL BULKY CALCIFIED LEAFLETS; (2) DURING PRE-DILATATION, NOTE BULKY CALCIFICATION ON VALVE MOVING TOWARDS OSTIUM ON LEFT MAIN; AND (3) CONSIDER AORTOGRAM DURING VALVULOPLASTY TO ASSESS CORONARY FLOW. THE EDWARDS THV MANUALS ALSO ADVISE THE OPERATOR ON PRE-PROCEDURE ASSESSMENT OF THE AORTIC VALVE, ROOT, AND CORONARY ANATOMY. PHYSICIANS ARE EXTENSIVELY TRAINED BY EDWARDS BEFORE THEY ARE QUALIFIED TO USE THE TRANSCATHETER HEART VALVE (THV). TRAINING INCLUDES PATIENT SCREENING, DEVICE PREPARATION, APPROACH, DEPLOYMENT, IMAGING, PROCEDURE-SPECIFIC TRAINING MANUALS, AND PROCTORED PROCEDURES. PER THE INSTRUCTIONS FOR USE (IFU), CORONARY OBSTRUCTION IS A POTENTIAL ADVERSE EVENT ASSOCIATED WITH THE TRANSCATHETER VALVE REPLACEMENT (TVR) PROCEDURE AND THE USE OF THE EDWARDS THV DEVICES. IN THIS CASE, THERE WAS NO ALLEGATION OR INDICATION A PRODUCT MALFUNCTION CONTRIBUTED TO THIS ADVERSE EVENT. INVESTIGATION RESULTS SUGGEST/INDICATE A SOFT TISSUE COMPONENT AND VALVE STENT STRUTS MAY HAVE CAUSED OR CONTRIBUTED TO THIS EVENT. A REVIEW OF EDWARDS LIFESCIENCES RISK MANAGEMENT DOCUMENTATION WAS PERFORMED FOR THIS CASE. THE REPORTED EVENT IS AN ANTICIPATED RISK OF THE TRANSCATHETER HEART VALVE PROCEDURE, ADDITIONAL ASSESSMENT OF THIS ADVERSE EVENT IS NOT REQUIRED AT THIS TIME. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS MONTHLY, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED.

Description of Event or Problem · 0

AS REPORTED BY THE EDWARDS (B)(4) AFFILIATE REVIEW OF THE LITERATURE ''LEFT CORONARY OSTIAL STENOSIS DEVELOPING 15 MONTHS AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT WITH BALLOON-EXPANDABLE VALVE'' APPROXIMATELY 15 MONTHS POST SUCCESSFUL TAVR A PATIENT'S LEFT CORONARY OSTIUM BECAME OBSTRUCTED. THE PATIENT UNDERWENT TAVR FOR SYMPTOMATIC SEVERE AORTIC STENOSIS WITH NO COMPLICATIONS. FIFTEEN MONTHS AFTER THE INITIAL TAVR, THE PATIENT COMPLAINED OF CHEST PAIN WHILE EXERCISING, AND THE EXERCISE STRESS MYOCARDIAL PERFUSION SCINTIGRAPHY DEMONSTRATED THE DEVELOPMENT OF REGIONAL MYOCARDIAL ISCHEMIA IN THE REGION OF THE LEFT CORONARY ARTERY. CORONARY ANGIOGRAPHY IMPLIED SEVERE STENOSIS IN THE OSTIUM OF THE LEFT CORONARY ARTERY. COMPUTED TOMOGRAPHY ANGIOGRAPHY AND INTRAVASCULAR ULTRASONOGRAPHY INDICATED A SOFT TISSUE COMPONENT ALONG WITH STENT STRUTS, WHICH WAS CONSIDERED TO CAUSE DELAYED CORONARY OBSTRUCTION. CABG WAS EXECUTED FOR THE REPORTED EVENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
654784 EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT EDWARDS LIFESCIENCES 9600TFX23J NA

Patients

Seq Age Sex Outcome Treatment
1 82 YR Male Required Intervention