FDA Adverse Event Malfunction Summary report: N

BD¿ CHOCOLATE AGAR (GC II AGAR WITH ISOVITALEX¿), PLATE, 90 MM X 120

MDR report key: 13934737 · Received March 29, 2022

Report

Report Number
9680577-2022-00042
Event Type
Malfunction
Date Received
March 29, 2022
Date of Event
February 28, 2022
Report Date
June 26, 2022
Manufacturer
BECTON DICKINSON GMBH
Product Code
JSO
PMA / PMN Number
SEE H10
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THERE IS NO 510(K) FOR THIS DEVICE AS IT IS MANUFACTURED OUTSIDE THE US AND NOT SOLD IN THE US BUT IS CONSIDERED TO BE SUBSTANTIALLY SIMILAR TO THE LEGALLY U.S. MARKETED DEVICE BD BBL¿ GC II AGAR WITH ISOVITALEX¿ ENRICHMENT CATALOG NUMBER 2212340 WITH 510(K) K945569. A DEVICE EVALUATION IS ANTICIPATED BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Additional Manufacturer Narrative · 0

H.6: EVENT DESCRIPTION: IT WAS REPORTED THAT UPON RECEIPT OF THE DELIVERY, MANY PLATES WERE BROKEN AND SOME PLATES WERE CONTAMINATED. COMPLAINT HISTORY REVIEW: COMPLAINT HISTORY OF THE AFFECTED BATCH WAS REVIEWED. THERE WERE NO SIMILAR COMPLAINTS REGISTERED. THEREFORE, A TREND COULD NOT BE IDENTIFIED. BATCH HISTORY RECORD (BHR) REVIEW: THE BHR WAS REVIEWED. NO DEVIATIONS FROM VALIDATED PROCESSES WERE REGISTERED. FURTHERMORE THE AFFECTED BATCH MET ALL REQUIRED RELEASE SPECIFICATIONS AND NO DEVIATION WAS REGISTERED DURING QC RELEASE TESTING. THERE WAS NEITHER A CONTAMINATION NOR BROKEN PLATES. STERILIZATION RECORD REVIEW: THE MEDIUM ITSELF IS HEAT STERILIZED. HOWEVER, THIS PRODUCT IS FILLED UNDER ASEPTIC CONDITIONS. SINCE A 100 % CONTROL FOR STERILITY IS NOT POSSIBLE A REPRESENTATIVE SAMPLING IS DONE BY THE QC DEPARTMENT. LOT NO. 2018457 COMPLIED TO OUR INTERNAL ACCEPTANCE QUALITY LIMIT (AQL) FOR STERILITY. SAMPLE ANALYSIS: PICTURE SAMPLE WAS PROVIDED SHOWING CONTAMINATION IN THE PLATE. FURTHERMORE, BROKEN PLATES WERE VISIBLE. RETAIN SAMPLES WERE ANALYZED. NO CONTAMINATION AND BROKEN PLATES WERE DETECTED. INVESTIGATION RESULTS AND CONCLUSION: ASEPTIC MANUFACTURING PROCESSES ARE UNABLE TO GUARANTEE STERILITY OF THE GIVEN PRODUCT. SINCE A 100 % INSPECTION IS NOT POSSIBLE FOR ASEPTIC PRODUCTS, STERILITY TESTING CARRIED OUT ON THE BASIS OF A REPRESENTATIVE SAMPLE. THEREFORE, OCCASIONAL CONTAMINATION CANNOT BE PREVENTED. NEVERTHELESS, TO IMPROVE CUSTOMER EXPERIENCE, AN INTERDISCIPLINARY TEAM WAS FOUNDED TO FURTHER REDUCE THE OCCURRENCE OF THESE SUBLIMINAL CONTAMINATIONS. EFFECTIVENESS CHECKS INDICATE A SIGNIFICANT IMPROVEMENT TO THE SITUATION CAUSED BY THE TRIGGERED ACTIONS. BD WILL CONTINUE TO MONITOR INCOMING COMPLAINTS FOR SIMILAR DEFECT TYPES. BROKEN PLATES MAY BE AN OUTCOME OF THE TRANSPORT OF THE PLATES. CONTAMINATED PLATES MAY BE A RESULT OF THE WRONG TRANSPORT. BASED ON THE INTERNAL INVESTIGATION AND THE PROVIDED PICTURES, THE COMPLAINT WAS CONFIRMED FOR CONTAMINATION AND BROKEN PLATES. NEITHER A TREND NOR A DEFINITE ROOT CAUSE COULD NOT BE IDENTIFIED.

Description of Event or Problem · 0

IT WAS REPORTED THAT PRIOR TO USE, BD¿ CHOCOLATE AGAR (GC II AGAR WITH ISOVITALEX¿), PLATE, 90 MM X 120 WERE CONTAMINATED. THERE WAS NO PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: ON RECEIPT OF THE DELIVERY, MANY BOXES ... WERE CONTAMINATED.

Description of Event or Problem · 0

IT WAS REPORTED THAT PRIOR TO USE, BD¿ CHOCOLATE AGAR (GC II AGAR WITH ISOVITALEX¿), PLATE, 90 MM X 120 WERE CONTAMINATED. THERE WAS NO PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: ON RECEIPT OF THE DELIVERY, MANY BOXES ... WERE CONTAMINATED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
25061 BD¿ CHOCOLATE AGAR (GC II AGAR WITH ISOVITALEX¿), PLATE, 90 MM X 120 CULTURE MEDIA, ANTIMICROBIAL SUSCEPTIBILITY TEST, EXCLUDING MUELLER HINTON JSO BECTON DICKINSON GMBH 2018457

Patients

Seq Age Sex Outcome Treatment
1 Unknown