FDA Adverse Event Injury Summary report: N

LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM

MDR report key: 1373526 · Received April 30, 2009

Report

Report Number
2024601-2009-00385
Event Type
Injury
Date Received
April 30, 2009
Date of Event
January 1, 2005
Report Date
April 2, 2009
Manufacturer
COSTA RICA
Product Code
LTI
PMA / PMN Number
P000008
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
TX, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

TAPER UNK. THE REPORTER OF THE COMPLAINT WAS ASKED TO RETURN THE PRODUCT FOR ANALYSIS AS WELL AS INDICATE THE PRODUCT SERIAL NUMBER, DATE OF EVENT, IMPLANT DATE AND EXPLANT DATE. SINCE ALLERGAN HAS NOT YET RECEIVED THIS INFORMATION THE CONNECTOR TYPE CANNOT BE IDENTIFIED NOR AN ASSUMPTION MADE AS TO THE TYPE OF CONNECTOR ASSOCIATED WITH THIS COMPLAINT. VISUAL EXAMINATION MAY DETERMINE THE CONNECTOR TYPE. ALLERGAN HAS NOT RECEIVED THE PRODUCT AT THIS TIME. THEREFORE, NO ANALYSIS OR TESTING HAS BEEN DONE. EROSION IS A SURGICAL/PHYSIOLOGICAL COMPLICATION AND ANALYSIS OF DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THIS EVENT. DEVICE LABELING: "AS WITH OTHER GASTROPLASTY SURGERIES, PARTICULAR CARE MUST BE TAKEN DURING DISSECTION AND DURING IMPLANTATION OF THE DEVICE TO AVOID DAMAGE TO THE GASTROINTESTINAL TRACT. ANY DAMAGE TO THE STOMACH DURING THE PROCEDURE MAY RESULT IN EROSION OF THE DEVICE INTO THE GI TRACT." "OVER-DISSECTION OF THE STOMACH DURING PLACEMENT MAY RESULT IN SLIPPAGE OR EROSION OF THE BAND AND REQUIRE REOPERATION." THERE IS A RISK OF BAND EROSION INTO STOMACH TISSUE. EROSION OF THE BAND INTO STOMACH TISSUE HAS BEEN ASSOCIATED WITH REVISION SURGERY AFTER THE USE OF GASTRIC-IRRITATING MEDICATIONS, AFTER STOMACH DAMAGE AND AFTER EXTENSIVE DISSECTION OR USE OF ELECTROCAUTERY, AND DURING EARLY EXPERIENCE. SYMPTOMS OF BAND EROSION MAY INCLUDE REDUCED WEIGHT LOSS, WEIGHT GAIN, ACCESS PORT INFECTION OR ABDOMINAL PAIN. RE-OPERATION TO REMOVE THE DEVICE IS REQUIRED,."

Description of Event or Problem · 1

REPORTED EVENT OF EROSION FROM JOURNAL ARTICLE: "LAPAROSCOPIC SLEEVE GASTRECTOMY AFTER GASTRIC BANDING REMOVAL: A FEASIBILITY STUDY". SURGICAL INNOVATION VOL. 16, NO. 1 MARCH 2009 68-72 SAGE PUBLICATIONS 10.1177/1553350608328866.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM DEVICE FOR TREATMENT OF MORBID OBESITY LTI COSTA RICA NA NI

Patients

Seq Age Sex Outcome Treatment
1 NI Required Intervention